Development, Monte Carlo simulations and experimental evaluation of a 3D range-modulator for a complex target in scanned proton therapy

被引:14
作者
Simeonov, Yuri [1 ,2 ]
Weber, Uli [3 ]
Schuy, Christoph [3 ]
Engenhart-Cabillic, Rita [4 ,5 ]
Penchev, Petar [1 ,2 ]
Flatten, Veronika [1 ,2 ,4 ,5 ]
Zink, Klemens [1 ,4 ,5 ]
机构
[1] Univ Appl Sci, Inst Med Phys & Radiat Protect IMPS, Giessen, Germany
[2] Philipps Univ, Marburg, Germany
[3] GSI Helmholtzzentrum Schwerionenforsch GmbH, Biophys Div, Darmstadt, Germany
[4] Univ Med Ctr Giessen Marburg, Dept Radiotherapy & Radiooncol, Marburg, Germany
[5] Marburg Ion Beam Therapy Ctr MIT, Marburg, Germany
来源
BIOMEDICAL PHYSICS & ENGINEERING EXPRESS | 2022年 / 8卷 / 03期
关键词
particle therapy; proton therapy; 3D range-modulator; 3D printing; FLUKA; monte carlo simulation; FLUKA CODE; DESIGN; CHALLENGES;
D O I
10.1088/2057-1976/ac5937
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of this work was to develop and manufacture a 3D range-modulator (3D RM) for a complex target contour for scanned proton therapy. The 3D RM is considered to be a viable technique for the very fast dose application in patient-specific tumors with only one fixed energy. The RM was developed based on a tumor from a patient CT and manufactured with high-quality 3D printing techniques with both polymer resin and aluminum. Monte Carlo simulations were utilized to investigate its modulating properties and the resulting dose distribution. Additionally, the simulation results were validated with measurements at the Marburg Ion-Beam Therapy Centre. For this purpose, a previously developed water phantom was used to conduct fast, automated high-resolution dose measurements. The results show a very good agreement between simulations and measurements and indicate that highly homogeneous dose distributions are possible. The delivered dose is conformed to the distal as well as to the proximal edge of the target. The 3D range-modulator concept combines a high degree of dose homogeneity and conformity, comparable to standard IMPT with very short irradiation times, promising clinically applicable dose distributions for lung and/or FLASH treatment, comparable and competitive to those from conventional irradiation techniques.
引用
收藏
页数:13
相关论文
共 31 条
  • [1] The FLASH effect depends on oxygen concentration
    Adrian, Gabriel
    Konradsson, Elise
    Lempart, Michael
    Back, Sven
    Ceberg, Crister
    Petersson, Kristoffer
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2020, 93 (1106)
  • [2] The FLUKA code for space applications:: recent developments
    Andersen, V
    Ballarini, F
    Battistoni, G
    Campanella, M
    Carboni, M
    Cerutti, F
    Empl, A
    Fassó, A
    Ferrari, A
    Gadioli, E
    Garzelli, MV
    Lee, K
    Ottolenghi, A
    Pelliccioni, M
    Pinsky, LS
    Ranft, J
    Roesler, S
    Sala, PR
    Wilson, TL
    [J]. SPACE LIFE SCIENCES: RADIATION RISK ASSESSMENT AND RADIATION MEASUREMENT IN LOW EARTH ORBIT, 2004, 34 (06): : 1302 - 1310
  • [3] Battistoni G., 2006, P 11 INT C NUCL REAC, V13, P1
  • [4] The FLUKA Code: An Accurate Simulation Tool For Particle Therapy
    Battistoni, Giuseppe
    Bauer, Julia
    Boehlen, Till T.
    Cerutti, Francesco
    Chin, Mary P. W.
    Augusto, Ricardo Dos Santos
    Ferrari, Alfredo
    Ortega, Pablo G.
    Kozlowska, Wioletta
    Magro, Giuseppe
    Mairani, Andrea
    Parodi, Katia
    Sala, Paola R.
    Schoofs, Philippe
    Tessonnier, Thomas
    Vlachoudis, Vasilis
    [J]. FRONTIERS IN ONCOLOGY, 2016, 6
  • [5] Quantification of interplay effects of scanned particle beams and moving targets
    Bert, Christoph
    Groezinger, Sven O.
    Rietzel, Eike
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (09) : 2253 - 2265
  • [6] The FLUKA Code: Developments and Challenges for High Energy and Medical Applications
    Boehlen, T. T.
    Cerutti, F.
    Chin, M. P. W.
    Fosso, A.
    Ferrari, A.
    Ortega, P. G.
    Mairani, A.
    Sala, P. R.
    Smirnov, G.
    Vlachoudisl, V.
    [J]. NUCLEAR DATA SHEETS, 2014, 120 : 211 - 214
  • [7] THE HEAVY NUCLEI OF THE PRIMARY COSMIC RADIATION
    BRADT, HL
    PETERS, B
    [J]. PHYSICAL REVIEW, 1950, 77 (01): : 54 - 70
  • [8] Cerutti F., 2006, LOW ENERGY NUCL NUCL, V1, P1
  • [9] Design, Implementation, and in Vivo Validation of a Novel Proton FLASH Radiation Therapy System
    Diffenderfer, Eric S.
    Verginadis, Ioannis I.
    Kim, Michele M.
    Shoniyozov, Khayrullo
    Velalopoulou, Anastasia
    Goia, Denisa
    Putt, Mary
    Hagan, Sarah
    Avery, Stephen
    Teo, Kevin
    Zou, Wei
    Lin, Alexander
    Swisher-McClure, Samuel
    Koch, Cameron
    Kennedy, Ann R.
    Minn, Andy
    Maity, Amit
    Busch, Theresa M.
    Dong, Lei
    Koumenis, Costas
    Metz, James
    Cengel, Keith A.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2020, 106 (02): : 440 - 448
  • [10] Faster and safer? FLASH ultra-high dose rate in radiotherapy
    Durante, Marco
    Brauer-Krisch, Elke
    Hill, Mark
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2018, 91 (1082)