Measurement of breast density with digital breast tomosynthesis-a systematic review

被引:44
作者
Ekpo, E. U. [1 ,2 ]
Mcentee, M. F. [1 ,2 ]
机构
[1] Univ Sydney, Fac Hlth Sci, Discipline Med Radiat Sci, Sydney, NSW 2006, Australia
[2] Univ Sydney, Brain & Mind Res Inst, Sydney, NSW 2006, Australia
关键词
BI-RADS CATEGORIES; MAMMOGRAPHIC DENSITY; CANCER RISK; REPRODUCIBILITY; SOFTWARE;
D O I
10.1259/bjr.20140460
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Digital breast tomosynthesis (DBT) has gained acceptance as an adjunct to digital mammography in screening. Now that breast density reporting is mandated in several states in the USA, it is increasingly important that the methods of breast density measurement be robust, reliable and consistent. Breast density assessment with DBT needs some consideration since quantitative methods are modelled for two-dimensional (2D) mammography. A review of methods used for breast density assessment with DBT was performed. Existing evidence shows Cumulus has better reproducibility than that of the breast imaging reporting and data system (BI-RADS (R)) but still suffers from subjective variability; MedDensity is limited by image noise, whilst Volpara and Quantra are robust and consistent. The reported BI-RADs inter-reader breast density agreement (k) ranged from 0.65 to 0.91, with inter-reader correlation (r) ranging from 0.70 to 0.93. The correlation (r) between BI-RADS and Cumulus ranged from 0.54-0.94, whilst that of BI-RADs and MedDensity ranged from 0.48-0.78. The reported agreement (k) between BI-RADs and Volpara is 0.953. Breast density correlation between DBT and 2D mammography ranged from 0.73 to 0.97, with agreement (k) ranging from 0.56 to 0.96. To avoid variability and provide more reliable breast density information for clinicians, automated volumetric methods are preferred.
引用
收藏
页数:9
相关论文
共 61 条
[41]   A Statistical Approach for Breast Density Segmentation [J].
Oliver, Arnau ;
Llado, Xavier ;
Perez, Elsa ;
Pont, Josep ;
Denton, Erika R. E. ;
Freixenet, Jordi ;
Marti, Joan .
JOURNAL OF DIGITAL IMAGING, 2010, 23 (05) :527-537
[42]   Mammographic density correlation with gail model breast cancer risk estimates and component risk factors [J].
Palomares, Melanie R. ;
Machia, Joelle R. B. ;
Lehman, Constance D. ;
Daling, Janet R. ;
McTiernan, Anne .
CANCER EPIDEMIOLOGY BIOMARKERS & PREVENTION, 2006, 15 (07) :1324-1330
[43]   Use of statistics to assess the global burden of breast cancer [J].
Parkin, DM ;
Fernández, LMG .
BREAST JOURNAL, 2006, 12 (01) :S70-S80
[44]   Diagnostic accuracy of digital versus film mammography: Exploratory analysis of selected population subgroups in DMIST [J].
Pisano, Etta D. ;
Hendrick, R. Edward ;
Yaffe, Martin J. ;
Baum, Janet K. ;
Acharyya, Suddhasatta ;
Cormack, Jean B. ;
Hanna, Lucy A. ;
Conant, Emily F. ;
Fajardo, Laurie L. ;
Bassett, Lawrence W. ;
D'Orsi, Carl J. ;
Jong, Roberta A. ;
Rebner, Murray ;
Tosteson, Anna N. A. ;
Gatsonis, Constantine A. .
RADIOLOGY, 2008, 246 (02) :376-383
[45]   Collagen reorganization at the tumor-stromal interface facilitates local invasion [J].
Provenzano, Paolo P. ;
Eliceiri, Kevin W. ;
Campbell, Jay M. ;
Inman, David R. ;
White, John G. ;
Keely, Patricia J. .
BMC MEDICINE, 2006, 4 (1)
[46]   Assessing Radiologist Performance Using Combined Digital Mammography and Breast Tomosynthesis Compared with Digital Mammography Alone: Results of a Multicenter, Multireader Trial [J].
Rafferty, Elizabeth A. ;
Park, Jeong Mi ;
Philpotts, Liane E. ;
Poplack, Steven P. ;
Sumkin, Jules H. ;
Halpern, Elkan F. ;
Niklason, Loren T. .
RADIOLOGY, 2013, 266 (01) :104-113
[47]   Inter- and intraradiologist variability in the BI-RADS assessment and breast density categories for screening mammograms [J].
Redondo, A. ;
Comas, M. ;
Macia, F. ;
Ferrer, F. ;
Murta-Nascimento, C. ;
Maristany, M. T. ;
Molins, E. ;
Sala, M. ;
Castells, X. .
BRITISH JOURNAL OF RADIOLOGY, 2012, 85 (1019) :1465-1470
[48]  
REGINI E, 2014, RADIOL MED, DOI DOI 10.1007/511547-014-0390-3
[49]   Measurement of breast density with digital breast tomosynthesis [J].
Ren, Baorui ;
Smith, Andrew ;
Jing, Zhenxue .
MEDICAL IMAGING 2012: PHYSICS OF MEDICAL IMAGING, 2012, 8313
[50]   Automated volumetric breast density estimation: A comparison with visual assessment [J].
Seo, J. M. ;
Ko, E. S. ;
Han, B. -K. ;
Ko, E. Y. ;
Shin, J. H. ;
Hahn, S. Y. .
CLINICAL RADIOLOGY, 2013, 68 (07) :690-695