The subcutaneous implantable cardioverter-defibrillator in review

被引:39
作者
Kamp, Nicholas J. [1 ]
Al-Khatib, Sana M. [1 ,2 ]
机构
[1] Duke Univ Hosp, Durham, NC USA
[2] Duke Clin Res Inst, Durham, NC USA
关键词
CLINICAL-OUTCOMES; ICD; EFFICACY; SAFETY; COMPLICATIONS; EXPERIENCE; TRIAL; RISK;
D O I
10.1016/j.ahj.2019.08.010
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The subcutaneous implantable cardioverter defibrillator (S-ICD) is a completely extrathoracic device that has recently been FDA approved for the prevention of sudden cardiac death in select populations. Although the transvenous implantable cardioverter defibrillator (TV-ICD) has a proven mortality benefit in multiple patient populations, there are significant risks both with implantation and years after its placement. The S-ICD may help prevent some of these complications. Currently, the S-ICD is typically implanted in patients with prior device infection or at an increased risk for an infection, younger patients with difficult venous access related to either hemodialysis or difficult cardiac anatomy, patients who live active lifestyles, and those who may outlive the TV-ICD leads. There is an absolute contraindication For S-ICD implantations for patients who need pacing either for ventricular tachycardia or bradycardia because this device cannot perform these functions. To date, there are no randomized controlled trial (RCT) data evaluating the safety and efficacy of this relatively new device. Observational studies of both the SICD alone and in comparison with the TV-ICD have showed promising results, including a decrease in lead-related and periprocedural complications as well as a high level of effectiveness at terminating ventricular arrhythmias. These analyses over time may have contributed to the evolution and comfortability with the S-ICD system, as physicians are more often referring for and/or implanting this device for patients with appropriate indications. Furthermore, inappropriate shock rates with the S-ICD have decreased over time especially with dual zone programming. This review summarizes the results of a multitude of observational studies with respect to patient selection for the S-ICD, complication rates, appropriate and inappropriate shock rates, and programming. This review also tackles current ongoing randomized trials. Although the results of ongoing trials will be helpful, there is still a continued need to evaluate the efficacy of the S-ICD in broader patient populations including patients with several comorbidities and older patients so that more patients can be considered for this potentially lifesaving device.
引用
收藏
页码:131 / 139
页数:9
相关论文
共 40 条
[1]  
Al-Khatib SM, 2018, CIRCULATION, V138, pE210, DOI [10.1161/CIR.0000000000000548, 10.1161/CIR.0000000000000549]
[2]   An Overview of Clinical Outcomes in Transvenous and Subcutaneous ICD Patients [J].
Baalman, S. W. E. ;
Quast, A. B. E. ;
Brouwer, T. F. ;
Knops, R. E. .
CURRENT CARDIOLOGY REPORTS, 2018, 20 (09)
[3]   Intra-operative defibrillation testing and clinical shock efficacy in patients with implantable cardioverter-defibrillators: the NORDIC ICD randomized clinical trial [J].
Baensch, Dietmar ;
Bonnemeier, Hendrik ;
Brandt, Johan ;
Bode, Frank ;
Svendsen, Jesper Hastrup ;
Taborsky, Milos ;
Kuster, Stefan ;
Blomstrom-Lundqvist, Carina ;
Felk, Angelika ;
Hauser, Tino ;
Suling, Anna ;
Wegscheider, Karl .
EUROPEAN HEART JOURNAL, 2015, 36 (37) :2500-2507
[4]   An Entirely Subcutaneous Implantable Cardioverter-Defibrillator [J].
Bardy, Gust H. ;
Smith, Warren M. ;
Hood, Margaret A. ;
Crozier, Ian G. ;
Melton, Iain C. ;
Jordaens, Luc ;
Theuns, Dominic ;
Park, Robert E. ;
Wright, David J. ;
Connelly, Derek T. ;
Fynn, Simon P. ;
Murgatroyd, Francis D. ;
Sperzel, Johannes ;
Neuzner, Joerg ;
Spitzer, Stefan G. ;
Ardashev, Andrey V. ;
Oduro, Amo ;
Boersma, Lucas ;
Maass, Alexander H. ;
Van Gelder, Isabelle C. ;
Wilde, Arthur A. ;
van Dessel, Pascal F. ;
Knops, Reinoud E. ;
Barr, Craig S. ;
Lupo, Pierpaolo ;
Cappato, Riccardo ;
Grace, Andrew A. .
NEW ENGLAND JOURNAL OF MEDICINE, 2010, 363 (01) :36-44
[5]  
Basu-Ray Indranill, 2017, JACC Clin Electrophysiol, V3, P1475, DOI 10.1016/j.jacep.2017.07.017
[6]  
Benjamin EJ, 2017, CIRCULATION, V135, pE146, DOI [10.1161/CIR.0000000000000485, 10.1161/CIR.0000000000000558, 10.1161/CIR.0000000000000530]
[7]   Implant and Midterm Outcomes of the Subcutaneous Implantable Cardioverter-Defibrillator Registry The EFFORTLESS Study [J].
Boersma, Lucas ;
Barr, Craig ;
Knops, Reinoud ;
Theuns, Dominic ;
Eckardt, Lars ;
Neuzil, Petr ;
Scholten, Marcoen ;
Hood, Margaret ;
Kuschyk, Juergen ;
Jones, Paul ;
Duffy, Elizabeth ;
Husby, Michael ;
Stein, Kenneth ;
Lambiase, Pier D. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2017, 70 (07) :830-841
[8]   Infection and mortality after implantation of a subcutaneous ICD after transvenous ICD extraction [J].
Boersma, Lucas ;
Burke, Martin C. ;
Neuzil, Petr ;
Lambiase, Pier ;
Friehling, Ted ;
Theuns, Dominic A. ;
Garcia, Fermin ;
Carter, Nathan ;
Stivland, Timothy ;
Weiss, Raul .
HEART RHYTHM, 2016, 13 (01) :157-164
[9]   Performance of the subcutaneous implantable cardioverter-defibrillator in patients with a primary prevention indication with and without a reduced ejection fraction versus patients with a secondary prevention indication [J].
Boersma, Lucas V. ;
Barr, Craig S. ;
Burke, Martin C. ;
Leon, Angel R. ;
Theuns, Dominic A. ;
Herre, John M. ;
Weiss, Raul ;
Kremers, Mark S. ;
Neuzil, Petr ;
Husby, Michael P. ;
Carter, Nathan ;
Stivland, Timothy M. ;
Gold, Michael R. .
HEART RHYTHM, 2017, 14 (03) :367-375
[10]   Propensity score matched comparison of subcutaneous and transvenous implantable cardioverter-defibrillator therapy in the SIMPLE and EFFORTLESS studies [J].
Brouwer, Tom F. ;
Knops, Reinoud E. ;
Kutyifa, Valentina ;
Barr, Craig ;
Mondesert, Blandine ;
Boersma, Lucas V. A. ;
Lambiase, Pier D. ;
Wold, Nicholas ;
Jones, Paul W. ;
Healey, Jeffrey S. .
EUROPACE, 2018, 20 :F240-F248