Influence of Horizontal Openings on Buoyancy-driven Natural Ventilation of an Atrium in High-rise Residential Buildings

被引:0
作者
Li, Jing [1 ]
Li, Nianping [1 ]
Li, Chuawang
Zhang, Minhui [1 ]
Hou, Sujuan [1 ]
He, Dongyue [1 ]
机构
[1] Hunan Univ, Coll Civil Engn, Changsha 410082, Hunan, Peoples R China
来源
6TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATING AND AIR CONDITIONING, VOLS I-III, PROCEEDINGS | 2009年
关键词
High-rise residential building; Atrium; Buoyancy-driven natural ventilation; Model experiment; Numerical simulation;
D O I
暂无
中图分类号
O414.1 [热力学];
学科分类号
摘要
The atrium is often designed in the center of high-rise residential building, and it is more like a light well without ceilings or floors from the bottom to the top. The stack effect of the atrium was mainly used to provide natural ventilation and passive cooling, however, there are many factors for the airflow and the characteristics of the atrium are complex. In this study a 10-storied residential building model has been employed to clarify the ventilation characteristics of the atrium and the rooms, which were effected by the different forms of lateral openings. The experiment was conducted under the effect of thermal buoyancy, and the similarity requirements were satisfied. At the same time, the prototype building was simulated numerically on the conditions. Results showed that high-rise residential buildings with atriums are at an advantage for the buoyancy-driven ventilation in lower part rooms and at a disadvantage for the upper part rooms. The enlargement of the numbers of opening floors causes the increase of the airflow rate through the atrium and the decrease of airflow rate through each floor. When the opening floors are evenly distributed along the building, the enlargement of the numbers of opening floors causes the increase of the temperature in the building at almost all heights, and an increase in temperatures with the height H can also be seen in the building.
引用
收藏
页码:1224 / 1231
页数:8
相关论文
共 6 条
[1]   Natural ventilation performance of a double-skin facade with a solar chimney [J].
Ding, WT ;
Hasemi, YJ ;
Yamada, T .
ENERGY AND BUILDINGS, 2005, 37 (04) :411-418
[2]  
KOTANI H, 1996, P ROOMVENT 96 YOK JA, V2, P299
[3]  
LONG TY, 2007, COMPUTATIONAL FLUIDS
[4]  
OHIRA N, 1996, P ROOMVENT96 YOK JAP, V3, P255
[5]  
TANG GF, 1989, INDOOR AIR SIMULATIO
[6]  
Tao W.Q., 2001, Numerical Heat Transfer, V2th