Accurate quantification of lipid species affected by isobaric overlap in Fourier-transform mass spectrometry

被引:56
作者
Hoering, Marcus [1 ]
Ejsing, Christer S. [2 ,3 ]
Krautbauer, Sabrina [1 ]
Ertl, Verena M. [1 ]
Burkhardt, Ralph [1 ]
Liebisch, Gerhard [1 ]
机构
[1] Regensburg Univ Hosp, Inst Clin Chem & Lab Med, Regensburg, Germany
[2] Univ Southern Denmark, Villum Ctr Bioanalyt Sci, Dept Biochem & Mol Biol, Odense, Denmark
[3] European Mol Biol Lab, Cell Biol & Biophys Unit, Heidelberg, Germany
关键词
lipidomics; mass spectrometry; lipids; phospholipids; sphingolipids; triglycerides; isotope correction; data processing; Fourier-transform mass spectrometry; peak interference; SHOTGUN LIPIDOMICS; EXTRACTS; TOOLS;
D O I
10.1016/j.jlr.2021.100050
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Lipidomics data require consideration of ions with near-identical masses, which comprises among others the Type-II isotopic overlap. This overlap occurs in series of lipid species differing only by number of double bonds (DBs) mainly because of the natural abundance of C-13-atoms. High-resolution mass spectrometry, such as Fourier-transform mass spectrometry (FTMS), is capable of resolving Type-II overlap depending on mass resolving power. In this work, we evaluated FTMS quantification accuracy of lipid species affected by Type-II overlap. Spike experiments with lipid species pairs of various lipid classes were analyzed by flow injection analysis-FTMS. Accuracy of quantification was evaluated without and with Type-II correction (using relative isotope abundance) as well as utilizing the first isotopic peak (M+1). Isobaric peaks, which were sufficiently resolved, were most accurate without Type-II correction. In cases of partially resolved peaks, we observed peak interference causing distortions in mass and intensity, which is a well-described phenomenon in FTMS. Concentrations of respective species were more accurate when calculated from M+1. Moreover, some minor species, affected by considerable Type-II overlap, could only be quantified by M+1. Unexpectedly, even completely unresolved peaks were substantially overcorrected by Type-II correction because of peak interference. The described method was validated including intraday and interday precisions for human serum and fibroblast samples. Taken together, our results show that accurate quantification of lipid species by FTMS requires resolution-depended data analysis.
引用
收藏
页数:11
相关论文
共 36 条
[1]   Comprehensive Lipidome Analysis by Shotgun Lipidomics on a Hybrid Quadrupole-Orbitrap-Linear Ion Trap Mass Spectrometer [J].
Almeida, Reinaldo ;
Pauling, Josch Konstantin ;
Sokol, Elena ;
Hannibal-Bach, Hans Kristian ;
Ejsing, Christer S. .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2015, 26 (01) :133-148
[2]   Advances in Mass Spectrometry for Lipidomics [J].
Blanksby, Stephen J. ;
Mitchell, Todd W. .
ANNUAL REVIEW OF ANALYTICAL CHEMISTRY, VOL 3, 2010, 3 :433-465
[3]  
BLIGH EG, 1959, CAN J BIOCHEM PHYS, V37, P911
[4]   MS-based lipidomics of human blood plasma: a community-initiated position paper to develop accepted guidelines [J].
Burla, Bo ;
Arita, Makoto ;
Arita, Masanori ;
Bendt, Anne K. ;
Cazenave-Gassiot, Amaury ;
Dennis, Edward A. ;
Ekroos, Kim ;
Han, Xianlin ;
Ikeda, Kazutaka ;
Liebisch, Gerhard ;
Lin, Michelle K. ;
Loh, Tze Ping ;
Meikle, Peter J. ;
Oresic, Matej ;
Quehenberger, Oswald ;
Shevchenko, Andrej ;
Torta, Federico ;
Wakelam, Michael J. O. ;
Wheelock, Craig E. ;
Wenk, Markus R. .
JOURNAL OF LIPID RESEARCH, 2018, 59 (10) :2001-2017
[5]   Growth and cell cycle abnormalities of fibroblasts from Tangier disease patients [J].
Drobnik, W ;
Liebisch, G ;
Biederer, C ;
Trümbach, B ;
Rogler, G ;
Müller, P ;
Schmitz, G .
ARTERIOSCLEROSIS THROMBOSIS AND VASCULAR BIOLOGY, 1999, 19 (01) :28-38
[6]   Automated identification and quantification of glycerophospholipid molecular species by multiple precursor ion scanning [J].
Ejsing, Christer S. ;
Duchoslav, Eva ;
Sampaio, Julio ;
Simons, Kai ;
Bonner, Ron ;
Thiele, Christoph ;
Ekroos, Kim ;
Shevchenko, Andrej .
ANALYTICAL CHEMISTRY, 2006, 78 (17) :6202-6214
[7]   Quantification of diacylglycerol and triacylglycerol species in human fecal samples by flow injection Fourier transform mass spectrometry [J].
Ertl, Verena M. ;
Hoering, Marcus ;
Schoett, Hans-Frieder ;
Bluecher, Christina ;
Kjolbaek, Louise ;
Astrup, Arne ;
Burkhardt, Ralph ;
Liebisch, Gerhard .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2020, 412 (10) :2315-2326
[8]   Spectral Accuracy of Molecular Ions in an LTQ/Orbitrap Mass Spectrometer and Implications for Elemental Composition Determination [J].
Erve, John C. L. ;
Gu, Ming ;
Wang, Yongdong ;
DeMaio, William ;
Talaat, Rasmy E. .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2009, 20 (11) :2058-2069
[9]   Observation of ion coalescence in Orbitrap Fourier transform mass spectrometry [J].
Gorshkov, Mikhail V. ;
Fornelli, Luca ;
Tsybin, Yury O. .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2012, 26 (15) :1711-1717
[10]   Phase-Constrained Spectrum Deconvolution for Fourier Transform Mass Spectrometry [J].
Grinfeld, Dmitry ;
Aizikov, Konstantin ;
Kreutzmann, Arne ;
Damoc, Eugen ;
Makarov, Alexander .
ANALYTICAL CHEMISTRY, 2017, 89 (02) :1202-1211