Correction of laser-induced incandescence signal trapping in soot measurement in a microgravity boundary layer laminar diffusion flame

被引:5
作者
Escudero, F. [1 ]
Cruz, J. J. [1 ]
Liu, F. [2 ]
Fuentes, A. [1 ]
机构
[1] Univ Tecn Federico Santa Maria, Dept Ind, Av Espana 1680,Casilla 110-5, Valparaiso, Chile
[2] CNR, Measurement Sci & Stand, Bldg M-9,1200 Montreal Rd, Ottawa, ON K1A 0R6, Canada
关键词
Planar LII; LII signal trapping; Soot volume fraction; Axisymmetric flame; 3D boundary layer flame; ABSORPTION; CALIBRATION;
D O I
10.1016/j.proci.2020.07.091
中图分类号
O414.1 [热力学];
学科分类号
摘要
This work presents a novel method to auto-correct the trapping effect of laser-induced incandescence (LII) signals inside the flame to obtain soot volume fraction distributions in laminar axisymmetric (2D) and threedimensional (3D) flames using planar LII. The development of the proposed model is described with an estimation of the propagated uncertainties. The proposed model is firstly numerically validated in a canonical 2D coflow Santoro flame using synthetic LII signals and soot properties predicted by the CoFlame code. Secondly, experimental measurements of LII were carried out in the same 2D coflow Santoro flame and the LII signals were converted to soot volume fraction using the proposed model. Simultaneous LII and line of-sight attenuation measurements were conducted to obtain the calibration factor. The proposed model automatically took into account the signal trapping effect in the conversion of the detected LII signal to soot volume fraction. Finally, the validated methodology is applied to a 3D laminar boundary layer diffusion flame established in microgravity. The significant differences in the measured soot volume fraction distributions with and without considering signal trapping, particularly in the 3D zone of the flame, demonstrate the importance of considering signal trapping to LII measurements of soot volume fraction in this flame. The model developed in this work can be readily applied in planar LII measurements of soot in any flame configuration as long as it is steady or statistically steady, to allow measurements to be performed at different positions inside a flame, such as for pool-fires or pulsating flames. (c) 2020 The Combustion Institute. Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:4825 / 4835
页数:11
相关论文
共 22 条
  • [11] 2D soot concentration and burning rate of a vertical PMMA slab using Laser-Induced Incandescence
    Hebert, Damien
    Coppalle, Alexis
    Talbaut, Martine
    [J]. PROCEEDINGS OF THE COMBUSTION INSTITUTE, 2013, 34 : 2575 - 2582
  • [12] Transport mechanisms controlling soot production inside a non-buoyant laminar diffusion flame
    Legros, G.
    Fuentes, A.
    Rouvreau, S.
    Joulain, P.
    Porterie, B.
    Torero, J. L.
    [J]. PROCEEDINGS OF THE COMBUSTION INSTITUTE, 2009, 32 : 2461 - 2470
  • [13] Legros G., 2006, COMBUST SCI TECHNOL
  • [14] Simultaneous soot temperature and volume fraction measurements in axis-symmetric flames by a two-dimensional modulated absorption/emission technique
    Legros, Guillaume
    Wang, Qianlong
    Bonnety, Jerome
    Kashif, Muhammad
    Morin, Celine
    Consalvi, Jean-Louis
    Liu, Fengshan
    [J]. COMBUSTION AND FLAME, 2015, 162 (06) : 2705 - 2719
  • [15] Numerical investigation of the effect of signal trapping on soot measurements using LII in laminar coflow diffusion flames
    Liu, F.
    Thomson, K. A.
    Smallwood, G. J.
    [J]. APPLIED PHYSICS B-LASERS AND OPTICS, 2009, 96 (04): : 671 - 682
  • [16] Effects of soot absorption and scattering on LII intensities in laminar coflow diffusion flames
    Liu, Fengshan
    Thomson, Kevin A.
    Smallwood, Gregory J.
    [J]. JOURNAL OF QUANTITATIVE SPECTROSCOPY & RADIATIVE TRANSFER, 2008, 109 (02) : 337 - 348
  • [17] Effects of primary particle diameter and aggregate size distribution on the temperature of soot particles heated by pulsed lasers
    Liu, FS
    Smallwood, GJ
    Snelling, DR
    [J]. JOURNAL OF QUANTITATIVE SPECTROSCOPY & RADIATIVE TRANSFER, 2005, 93 (1-3) : 301 - 312
  • [18] Absorption correction of two-color laser-induced incandescence signals for soot volume fraction measurements
    Migliorini, Francesca
    De Iuliis, Silvana
    Cignoli, Francesco
    Zizak, Giorgio
    [J]. APPLIED OPTICS, 2006, 45 (29) : 7706 - 7711
  • [19] SOOT PARTICLE MEASUREMENTS IN DIFFUSION FLAMES
    SANTORO, RJ
    SEMERJIAN, HG
    DOBBINS, RA
    [J]. COMBUSTION AND FLAME, 1983, 51 (02) : 203 - 218
  • [20] Laser-induced incandescence: recent trends and current questions
    Schulz, C.
    Kock, B. F.
    Hofmann, M.
    Michelsen, H.
    Will, S.
    Bougie, B.
    Suntz, R.
    Smallwood, G.
    [J]. APPLIED PHYSICS B-LASERS AND OPTICS, 2006, 83 (03): : 333 - 354