EFFECT OF BUILDING PLAN FORM ON HUMAN THERMAL COMFORT IN NATURALLY VENTILATED OPEN-PLAN ENCLOSURES LOCATED IN HOT CLIMATES

被引:2
|
作者
Asfour, Omar S. [1 ]
机构
[1] Islamic Univ Gaza, Dept Architecture, Fac Engn, POB 108, Gaza City, Palestine
来源
JOURNAL OF GREEN BUILDING | 2017年 / 12卷 / 02期
关键词
natural ventilation; buildings; open-plan; thermal comfort; hot climate; DRIVEN CROSS VENTILATION; WIND-TUNNEL; SHAPES; FLOW;
D O I
10.3992/1943-4618.12.2.112
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This study aims to examine the effect of building plan form on internal thermal comfort conditions in naturally ventilated open-plan buildings located in hot climates. The study examined the square and the rectangular plan forms in relation to several values of wind direction, building plan depth, and climatic conditions. The study utilised CFD for ventilation prediction, DesignBuilder for thermal modelling, and the Tropical Summer Index (TSI) for thermal comfort assessment. These three tools were integrated in a quantitative approach to fulfil the study aim. The study concluded that the use of area-weighted average velocity magnitude is more accurate in the assessment of natural ventilation performance, as it accounts for both internal velocity magnitude and distribution. The study confirmed the common observation that the use of shallow building plans is more effective to increase internal air velocity and improve internal thermal comfort. At some point of increased plan depth, the internal air velocity magnitude dramatically decreases. In the three examined wind directions, this occurred when the plan depth exceeded 3H in the square cases and 2.5H in the rectangular ones, where H is the building height. This value is much less than the commonly recommended maximum value of 5H. The study also concluded that reducing building depth in the square cases has generally more potential to improve thermal comfort conditions when compared with the rectangular cases. The gross increase in Percentage of People Comfortable, PPC, in all the examined cases was 23% in the square cases, compared to 11% in the rectangular cases.
引用
收藏
页码:112 / 129
页数:18
相关论文
共 20 条
  • [1] Energy efficient thermal comfort in open-plan office buildings
    Nagarathinam, Srinarayana
    Doddi, Harish
    Vasan, Arunchandar
    Sarangan, Venkatesh
    Ramakrishna, Venkata P.
    Sivasubramaniam, Anand
    ENERGY AND BUILDINGS, 2017, 139 : 476 - 486
  • [2] The effect of building plan form on thermal comfort in the traditional residential patterns of the hot and dry climate of Qom
    Mohammad Sadegh Taher Tolou Del
    Susan Bayat
    Niloofar Zojaji
    Heritage Science, 10
  • [3] The effect of building plan form on thermal comfort in the traditional residential patterns of the hot and dry climate of Qom
    Del, Mohammad Sadegh Taher Tolou
    Bayat, Susan
    Zojaji, Niloofar
    HERITAGE SCIENCE, 2022, 10 (01)
  • [4] Effect of building interface form on thermal comfort in gymnasiums in hot and humid climates
    Huang, Xiaodan
    Ma, Xiaoli
    Zhang, Qingyuan
    FRONTIERS OF ARCHITECTURAL RESEARCH, 2019, 8 (01) : 32 - 43
  • [5] Modelling spatial variations in thermal comfort in indoor open-plan spaces using a whole-building simulation tool
    Vidhyashankar, Rakshitha
    Vinze, Ravish
    Nagarathinam, Srinarayana
    Natrajan, Vinay K.
    JOURNAL OF BUILDING ENGINEERING, 2022, 46
  • [6] Indoor air quality and occupant satisfaction in five mechanically and four naturally ventilated open-plan office buildings
    Hummelgaard, J.
    Juhl, P.
    Saebjornsson, K. O.
    Clausen, G.
    Toftum, J.
    Langkilde, G.
    BUILDING AND ENVIRONMENT, 2007, 42 (12) : 4051 - 4058
  • [7] Indoor air quality and occupant satisfaction in five mechanically and four naturally ventilated open-plan office buildings
    Hummelgaard, J
    Juhl, P
    Sæbjörnsson, KO
    Clausen, G
    Toftum, J
    Langkilde, G
    INDOOR AIR 2005: PROCEEDINGS OF THE 10TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY AND CLIMATE, VOLS 1-5, 2005, : 675 - 680
  • [8] The effect of slightly warm temperature on work performance and comfort in open-plan offices - a laboratory study
    Maula, H.
    Hongisto, V.
    Ostman, L.
    Haapakangas, A.
    Koskela, H.
    Hyona, J.
    INDOOR AIR, 2016, 26 (02) : 286 - 297
  • [9] Comparing thermal comfort and air quality performance of two active chilled beam systems in an open-plan office
    Cehlin, Mathias
    Karimipanah, Taghi
    Larsson, Ulf
    Ameen, Arman
    JOURNAL OF BUILDING ENGINEERING, 2019, 22 : 56 - 65
  • [10] Optimization of Architectural Form for Thermal Comfort in Naturally Ventilated Gymnasium at Hot and Humid Climate by Orthogonal Experiment
    Huang, Xiaodan
    Zhang, Qingyuan
    Tanaka, Ineko
    ENERGIES, 2021, 14 (11)