Analysis and correction of field fluctuations in fMRI data using field monitoring

被引:29
作者
Bollmann, Saskia [1 ,2 ,7 ]
Kasper, Lars [1 ,2 ,3 ,4 ]
Vannesjo, S. Johanna [1 ,2 ,8 ]
Diaconescu, Andreea O. [3 ,4 ]
Dietrich, Benjamin E. [1 ,2 ]
Gross, Simon [1 ,2 ]
Stephan, Klaas E. [3 ,4 ,5 ,6 ]
Pruessmann, Klaas P. [1 ,2 ]
机构
[1] Swiss Fed Inst Technol, Inst Biomed Engn, CH-8092 Zurich, Switzerland
[2] Univ Zurich, CH-8092 Zurich, Switzerland
[3] Univ Zurich, Inst Biomed Engn, TNU, CH-8032 Zurich, Switzerland
[4] Swiss Fed Inst Technol, CH-8032 Zurich, Switzerland
[5] UCL, Wellcome Trust Ctr Neuroimaging, London WC1N 3BG, England
[6] Max Planck Inst Metab Res, D-50931 Cologne, Germany
[7] Univ Queensland, Ctr Adv Imaging, Brisbane, Qld 4072, Australia
[8] Univ Oxford, Nuffield Dept Clin Neurosci, FMRIB Ctr, Oxford, England
关键词
fMRI; Echo-planar imaging; Field fluctuations; Physiological noise; SFNR; Magnetic field monitoring; INDEPENDENT COMPONENT ANALYSIS; INDUCED B-0 FLUCTUATIONS; STATIC MAGNETIC-FIELD; ECHO-PLANAR; HUMAN BRAIN; PHYSIOLOGICAL NOISE; RETROSPECTIVE CORRECTION; IMAGE-RECONSTRUCTION; SUBJECT MOTION; FUNCTIONAL MRI;
D O I
10.1016/j.neuroimage.2017.01.014
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
This work investigates the role of magnetic field fluctuations as a confound in fMRI. In standard fMRI experiments with single-shot EPI acquisition at 3 Tesla the uniform and gradient components of the magnetic field were recorded with NMR field sensors. By principal component analysis it is found that differences of field evolution between the EPI readouts are explainable by few components relating to slow and within-shot field dynamics of hardware and physiological origin. The impact of fluctuating field components is studied by selective data correction and assessment of its influence on image fluctuation and SFNR. Physiological field fluctuations, attributed to breathing, were found to be small relative to those of hardware origin. The dominant confounds were hardware-related and attributable to magnet drift and thermal changes. In raw image time series, field fluctuation caused significant SFNR loss, reflected by a 67% gain upon correction. Large part of this correction can be accomplished by traditional image realignment, which addresses slow and spatially uniform field changes. With realignment, explicit field correction increased the SFNR on the order of 6%. In conclusion, field fluctuations are a relevant confound in fMRI and can be addressed effectively by retrospective data correction. Based on the physics involved it is anticipated that the advantage of full field correction increases with field strength, with non-Cartesian readouts, and upon phase-sensitive BOLD analysis.
引用
收藏
页码:92 / 105
页数:14
相关论文
共 80 条
  • [1] Real-time measurement and correction of both B0 changes and subject motion in diffusion tensor imaging using a double volumetric navigated (DvNav) sequence
    Alhamud, A.
    Taylor, Paul A.
    van der Kouwe, Andre J. W.
    Meintjes, Ernesta M.
    [J]. NEUROIMAGE, 2016, 126 : 60 - 71
  • [2] Modeling geometric deformations in EPI time series
    Andersson, JLR
    Hutton, C
    Ashburner, J
    Turner, R
    Friston, K
    [J]. NEUROIMAGE, 2001, 13 (05) : 903 - 919
  • [3] How to correct susceptibility distortions in spin-echo echo-planar images: application to diffusion tensor imaging
    Andersson, JLR
    Skare, S
    Ashburner, J
    [J]. NEUROIMAGE, 2003, 20 (02) : 870 - 888
  • [4] Ashburner J, 2007, STATISTICAL PARAMETRIC MAPPING: THE ANALYSIS OF FUNCTIONAL BRAIN IMAGES, P49, DOI 10.1016/B978-012372560-8/50004-8
  • [5] Unified segmentation
    Ashburner, J
    Friston, KJ
    [J]. NEUROIMAGE, 2005, 26 (03) : 839 - 851
  • [6] TIME COURSE EPI OF HUMAN BRAIN-FUNCTION DURING TASK ACTIVATION
    BANDETTINI, PA
    WONG, EC
    HINKS, RS
    TIKOFSKY, RS
    HYDE, JS
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1992, 25 (02) : 390 - 397
  • [7] Barmet C., 2010, P INT SOC MAG RESON, V18, P216
  • [8] Spatiotemporal magnetic field monitoring for MR
    Barmet, Christoph
    De Zanche, Nicola
    Pruessmann, Klaas P.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2008, 60 (01) : 187 - 197
  • [9] A Transmit/Receive System for Magnetic Field Monitoring of In Vivo MRI
    Barmet, Christoph
    De Zanche, Nicola
    Wilm, Bertram J.
    Pruessmann, Klaas P.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2009, 62 (01) : 269 - 276
  • [10] SMOOTHING PERIODOGRAMS FROM TIME-SERIES WITH CONTINUOUS SPECTRA
    BARTLETT, MS
    [J]. NATURE, 1948, 161 (4096) : 686 - 687