CLT Shear Walls Anchored with Shear-Tension Angle Brackets: Experimental Tests and Finite-Element Modeling

被引:21
作者
D'Arenzo, Giuseppe [1 ]
Casagrande, Daniele [2 ]
Polastri, Andrea [2 ]
Fossetti, Marinella [3 ]
Fragiacomo, Massimo [4 ]
Seim, Werner [1 ]
机构
[1] Univ Kassel, Bldg Rehabil & Timber Engn, Kurt Wolters St 3, D-34125 Kassel, Germany
[2] Natl Res Council Italy, Inst Bioecon, Via Biasi 75, I-38010 San Michele All Adige, Italy
[3] Kore Univ Enna, Fac Engn & Architecture, I-94100 Enna, Italy
[4] Univ LAquila, Dept Civil Construct Architectural & Environm Eng, I-67100 Laquila, Italy
关键词
Cross-laminated timber; Wall-to-floor connection; Experimental tests; Finite element (FE) modeling; Coupled shear-tension behavior; Strength domain; Plastic load redistribution; BEHAVIOR; CONNECTIONS;
D O I
10.1061/(ASCE)ST.1943-541X.0003008
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Due to the high in-plane stiffness and strength capacity of cross-laminated timber (CLT) panels, the mechanical behavior of CLT shear walls is mainly influenced by the mechanical performances of the connections. Several calculation models have been proposed considering the mechanical anchors effectiveness only along their primary direction. However, recent studies showed a relatively high stiffness and capacity of new typologies of angle brackets when subjected to uplift vertical loads, such as for the wall-to-floor Titan V (TTV) angle bracket, developed to obtain high mechanical performances along both the vertical-tensile and horizontal-shear direction. In this paper a study on CLT shear walls anchored with TTV angle bracket is presented. The aim of the work is to investigate the effects of the coupled shear-tension behavior of the connections at the wall level and the effectiveness of TTVas an alternative to traditional mechanical anchors. The paper presents results from full-scale experimental tests and finite-element (FE) numerical analyses in SAP2000, where an innovative macroelement has been developed to model the TTV coupled shear-tension behavior. The effects of the plastic load redistributions of the TTV angle bracket on the global mechanical behavior of the CLT shear wall are discussed. (C) 2021 American Society of Civil Engineers.
引用
收藏
页数:15
相关论文
共 39 条
[1]  
[Anonymous], 2014, P INT NETW TIMB ENG
[2]  
Bla H. J., 2004, P WORLD C TIMB ENG
[3]  
Blass H.J., 2004, P 8 WORLD C TIMB ENG, V2, P435
[4]  
Bogensperger T, 2010, 11 WORLD C TIMB ENG, P231
[5]   Cross laminated timber (CLT) diaphragms under shear: Test configuration, properties and design [J].
Brandner, Reinhard ;
Dietsch, Philipp ;
Droescher, Julia ;
Schulte-Wrede, Michael ;
Kreuzinger, Heinrich ;
Sieder, Mike .
CONSTRUCTION AND BUILDING MATERIALS, 2017, 147 :312-327
[6]  
Casagrande D. A., 2016, P WORLD C TIMB ENG V
[7]   A methodology to determine the seismic low-cycle fatigue strength of timber connections [J].
Casagrande, Daniele ;
Bezzi, Stefano ;
D'Arenzo, Giuseppe ;
Schwendner, Sascha ;
Polastri, Andrea ;
Seim, Werner ;
Piazza, Maurizio .
CONSTRUCTION AND BUILDING MATERIALS, 2020, 231
[8]   Proposal of an analytical procedure and a simplified numerical model for elastic response of single-storey timber shear-walls [J].
Casagrande, Daniele ;
Rossi, Simone ;
Sartori, Tiziano ;
Tomasi, Roberto .
CONSTRUCTION AND BUILDING MATERIALS, 2016, 102 :1101-1112
[9]   SOFIE project-3D shaking table test on a seven-storey full-scale cross-laminated timber building [J].
Ceccotti, Ario ;
Sandhaas, Carmen ;
Okabe, Minoru ;
Yasumura, Motoi ;
Minowa, Chikahiro ;
Kawai, Naohito .
EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2013, 42 (13) :2003-2021
[10]  
CEN (European Committee for Standardization), 2005, 125122001A1 CEN