Implantation of a synthetic meniscal scaffold improves joint contact mechanics in a partial meniscectomy cadaver model

被引:34
作者
Brophy, Robert H. [2 ]
Cottrell, Jocelyn [1 ]
Rodeo, Scott A. [3 ]
Wright, Timothy M. [1 ]
Warren, Russell F. [3 ]
Maher, Suzanne A. [1 ]
机构
[1] Hosp Special Surg, Dept Biomech, New York, NY 10021 USA
[2] Washington Univ, Sch Med, Dept Orthopaed Surg, St Louis, MO 63110 USA
[3] Hosp Special Surg, Sports Med & Shoulder Serv, New York, NY 10021 USA
关键词
meniscus; scaffold; biomechanics; knee-contact mechanics; PARTIAL LATERAL MENISCECTOMY; COLLAGEN MENISCUS; HUMAN KNEE; POLYMER SCAFFOLD; TIBIAL PLATEAU; SHEEP MODEL; FOLLOW-UP; IN-VIVO; REGENERATION; REPLACEMENT;
D O I
10.1002/jbm.a.32384
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Meniscal substitutes should ideally distribute loads across adjacent articular cartilage much in the way of the native tissue, thereby protecting the cartilage from degeneration. The objective of this study was to quantify the loads transferred to the tibial plateau after implantation of a porous polyurethane scaffold. Our hypothesis was that scaffold implantation would improve the contact mechanics of a partial meniscectomy knee. Six sheep cadaver knees were mounted in a load-controlled knee-joint simulator. A pressure-sensor sheet, secured to the tibial plateau, dynamically recorded pressure data over 10 gait cycles for the following conditions: (i) intact, (ii) partial meniscectomy, (iii) implanted scaffold, and (iv) total meniscectomy. Implantation of the scaffold increased the contact area and decreased the contact pressures compared to the meniscal defect knee. No significant difference was found between the average and peak contact pressures of the intact knees and scaffold-implanted knees; however, contact area was significantly lower for the scaffold-implanted knees compared to intact knees. Our hypothesis was accepted; replacement with a polyurethane scaffold improved knee-contact mechanics relative to a partially meniscectomized knee. On the basis of these findings, the scaffold will be evaluated for its chondro-protective capacity in an in vivo ovine model. (C) 2009 Wiley Periodicals, Inc. J Biomed Mater Res 92A: 1154-1161, 2010
引用
收藏
页码:1154 / 1161
页数:8
相关论文
共 42 条
  • [1] Effect of high tibial flexion osteotomy on cartilage pressure and joint kinematics: a biomechanical study in human cadaveric knees - Winner of the AGA-DonJoy Award 2004
    Agneskirchner, JD
    Hurschler, C
    Stukenborg-Colsman, C
    Imhoff, AB
    Lobenhoffer, P
    [J]. ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2004, 124 (09) : 575 - 584
  • [2] Contact mechanics of the medial tibial plateau after implantation of a medial meniscal allograft - A human cadaveric study
    Alhalki, MM
    Hull, ML
    Howell, SM
    [J]. AMERICAN JOURNAL OF SPORTS MEDICINE, 2000, 28 (03) : 370 - 376
  • [3] The natural history of the knee following arthroscopic medial meniscectomy
    Chatain, F
    Robinson, AHN
    Adeleine, P
    Chambat, P
    Neyret, P
    [J]. KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2001, 9 (01) : 15 - 18
  • [4] A tissue engineering approach to meniscus regeneration in a sheep model
    Chiari, C.
    Koller, U.
    Dorotka, R.
    Eder, C.
    Plasenzotti, R.
    Lang, S.
    Ambrosio, L.
    Tognana, E.
    Kon, E.
    Salter, D.
    Nehrer, S.
    [J]. OSTEOARTHRITIS AND CARTILAGE, 2006, 14 (10) : 1056 - 1065
  • [5] Cicuttini FM, 2002, J RHEUMATOL, V29, P1954
  • [6] Long-term outcome for large meniscal defects treated with small intestinal submucosa in a dog model
    Cook, JL
    Fox, DB
    Malaviya, P
    Tomlinson, JL
    Kuroki, K
    Cook, CR
    Kladakis, S
    [J]. AMERICAN JOURNAL OF SPORTS MEDICINE, 2006, 34 (01) : 32 - 42
  • [7] A new technique to measure the dynamic contact pressures on the Tibial Plateau
    Cottrell, Jocelyn M.
    Scholten, Paul
    Wanich, Tony
    Warren, Russell F.
    Wright, Timothy M.
    Maher, Suzanne A.
    [J]. JOURNAL OF BIOMECHANICS, 2008, 41 (10) : 2324 - 2329
  • [8] de Groot Jacqueline H, 2005, Med Device Technol, V16, P18
  • [9] Meniscal tissue regeneration in porous 50/50 copoly(L-lactide/epsilon-caprolactone) implants
    deGroot, JH
    Zijlstra, FM
    Kuipers, HW
    Pennings, AJ
    Klompmaker, J
    Veth, RPH
    Jansen, HWB
    [J]. BIOMATERIALS, 1997, 18 (08) : 613 - 622
  • [10] How the stiffness of meniscal attachments and meniscal material properties affect tibio-femoral contact pressure computed using a validated finite element model of the human knee joint
    Donahue, TLH
    Hull, ML
    Rashid, MM
    Jacobs, CR
    [J]. JOURNAL OF BIOMECHANICS, 2003, 36 (01) : 19 - 34