MR-Guided Vertebroplasty With Augmented Reality Image Overlay Navigation

被引:25
|
作者
Fritz, Jan [1 ]
U-Thainual, Paweena [2 ,3 ,4 ,5 ]
Ungi, Tamas [4 ]
Flammang, Aaron J. [6 ]
Kathuria, Sudhir [1 ]
Fichtinger, Gabor [4 ]
Iordachita, Iulian I. [2 ,3 ]
Carrino, John A. [1 ]
机构
[1] Johns Hopkins Univ, Sch Med, Russell H Morgan Dept Radiol & Radiol Sci, Baltimore, MD 21287 USA
[2] Johns Hopkins Univ, Dept Mech Engn, Baltimore, MD 21218 USA
[3] Johns Hopkins Univ, Lab Computat Sensing & Robot, Baltimore, MD 21218 USA
[4] Queens Univ, Sch Comp, Kingston, ON K7L 2N8, Canada
[5] Queens Univ, Dept Mech & Mat Engn, Kingston, ON K7L 3N6, Canada
[6] Siemens Healthcare USA Inc, Malvern, PA 19355 USA
关键词
Vertebroplasty; Interventional MR imaging; MR imaging guidance; MR-guided; SPINAL INJECTION PROCEDURES; PERCUTANEOUS VERTEBROPLASTY; BONE-BIOPSY; INTERVENTIONS; ABLATION; VISUALIZATION; FEASIBILITY; ACCURACY; PERFORMANCE; TECHNOLOGY;
D O I
10.1007/s00270-014-0885-2
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
To evaluate the feasibility of magnetic resonance imaging (MRI)-guided vertebroplasty at 1.5 Tesla using augmented reality image overlay navigation. Twenty-five unilateral vertebroplasties [5 of 25 (20 %) thoracic, 20 of 25 (80 %) lumbar] were prospectively planned in 5 human cadavers. A clinical 1.5-Teslan MRI system was used. An augmented reality image overlay navigation system and 3D Slicer visualization software were used for MRI display, planning, and needle navigation. Intermittent MRI was used to monitor placement of the MRI-compatible vertebroplasty needle. Cement injections (3 ml of polymethylmethacrylate) were performed outside the bore. The cement deposits were assessed on intermediate-weighted MR images. Outcome variables included type of vertebral body access, number of required intermittent MRI control steps, location of final needle tip position, cement deposit location, and vertebroplasty time. All planned procedures (25 of 25, 100 %) were performed. Sixteen of 25 (64 %) transpedicular and 9 of 25 (36 %) parapedicular access routes were used. Six (range 3-9) MRI control steps were required for needle placement. No inadvertent punctures were visualized. Final needle tip position and cement location were adequate in all cases (25 of 25, 100 %) with a target error of the final needle tip position of 6.1 +/- A 1.9 mm (range 0.3-8.7 mm) and a distance between the planned needle tip position and the center of the cement deposit of 4.3 mm (range 0.8-6.8 mm). Time requirement for one level was 16 (range 11-21) min. MRI-guided vertebroplasty using image overlay navigation is feasible allowing for accurate vertebral body access and cement deposition in cadaveric thoracic and lumbar vertebral bodies.
引用
收藏
页码:1589 / 1596
页数:8
相关论文
共 50 条
  • [31] Focusing through the Rib Cage for MR-guided Transcostal FUS
    Gao, J.
    Volovick, A.
    Pekelny, Y.
    Huang, Z. H.
    Cochran, S.
    Melzer, A.
    11TH INTERNATIONAL SYMPOSIUM ON THERAPEUTIC ULTRASOUND, 2012, 1481 : 94 - 99
  • [32] Augmented Reality Visualization With Image Overlay for MRI-Guided Intervention: Accuracy for Lumbar Spinal Procedures With a 1.5-T MRI System
    Fritz, Jan
    U-Thainual, Paweena
    Ungi, Tamas
    Flammang, Aaron J.
    Cho, Nathan B.
    Fichtinger, Gabor
    Iordachita, Iulian I.
    Carrino, John A.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 198 (03) : W266 - W273
  • [33] MR-Guided Dynamic PET Image Reconstruction with the Kernel Method and Spectral Basis Functions
    Novosad, Philip
    Reader, Andrew J.
    2015 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2015,
  • [34] Augmented Reality to Compensate for Navigation Inaccuracies
    Bopp, Miriam H. A.
    Corr, Felix
    Sass, Benjamin
    Pojskic, Mirza
    Kemmling, Andre
    Nimsky, Christopher
    SENSORS, 2022, 22 (24)
  • [35] MR-guided proton therapy: a review and a preview
    Hoffmann, Aswin
    Oborn, Bradley
    Moteabbed, Maryam
    Yan, Susu
    Bortfeld, Thomas
    Knopf, Antje
    Fuchs, Herman
    Georg, Dietmar
    Seco, Joao
    Spadea, Maria Francesca
    Jaekel, Oliver
    Kurz, Christopher
    Parodi, Katia
    RADIATION ONCOLOGY, 2020, 15 (01)
  • [36] MR-Guided Adaptive Radiotherapy for Bladder Cancer
    Hijab, Adham
    Tocco, Boris
    Hanson, Ian
    Meijer, Hanneke
    Nyborg, Christina Junker
    Bertelsen, Anders Smedegaard
    Smeenk, Robert Jan
    Smith, Gillian
    Michalski, Jeff
    Baumann, Brian C.
    Hafeez, Shaista
    FRONTIERS IN ONCOLOGY, 2021, 11
  • [37] MR-guided percutaneous sclerotherapy of low-flow vascular malformations: Clinical experience using a 1.5 tesla MR system
    O'Mara, Daniel M.
    DiCamillo, Paul A.
    Gilson, Wesley D.
    Herzka, Daniel A.
    Wacker, Frank K.
    Lewin, Jonathan S.
    Weiss, Clifford R.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2017, 45 (04) : 1154 - 1162
  • [38] Augmented Reality in Surgical Navigation: A Review of Evaluation and Validation Metrics
    Malhotra, Shivali
    Halabi, Osama
    Dakua, Sarada Prasad
    Padhan, Jhasketan
    Paul, Santu
    Palliyali, Waseem
    APPLIED SCIENCES-BASEL, 2023, 13 (03):
  • [39] MR-guided proton therapy: Impact of magnetic fields on the detector response
    Fuchs, Hermann
    Padilla-Cabal, Fatima
    Zimmermann, Lukas
    Palmans, Hugo
    Georg, Dietmar
    MEDICAL PHYSICS, 2021, 48 (05) : 2572 - 2579
  • [40] MR-guided focused ultrasound robot for performing experiments on large animals
    Mylonas, N.
    Damianou, C.
    10TH INTERNATIONAL SYMPOSIUM ON THERAPEUTIC ULTRASOUND (ISTU 2010), 2011, 1359 : 151 - 156