Predicting the permeability of trabecular bone by micro-computed tomography and finite element modeling

被引:34
|
作者
Sandino, Clara [1 ,2 ,3 ]
Kroliczek, Paul [1 ,2 ,3 ]
McErlain, David D. [1 ,2 ,3 ]
Boyd, Steven K. [1 ,2 ,3 ,4 ]
机构
[1] Univ Calgary, McCaig Inst Bone & Joint Hlth, Calgary, AB T2N 4Z6, Canada
[2] Univ Calgary, Schulich Sch Engn, Calgary, AB T2N 4Z6, Canada
[3] Univ Calgary, Roger Jackson Ctr Hlth & Wellness Res, Calgary, AB T2N 4Z6, Canada
[4] Univ Calgary, Fac Med, Dept Radiol, Calgary, AB T2N 4Z6, Canada
关键词
Permeability; Trabecular bone; Micro computed tomography; Finite element models; CANCELLOUS BONE; CEMENT INFILTRATION;
D O I
10.1016/j.jbiomech.2014.06.024
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The intrinsic permeability of bone plays an important role in the transport of nutrients and minerals within the tissue, and affects the mechanical stimuli that are related to the fate of the stem cells. The objective of this study was to establish a method to assess trabecular bone permeability using experimental and finite element (FE) modeling approaches based on micro computed tomography (mu CT) images. Human cadaveric tibia cube specimens (N=23) were scanned with gCT. The permeability was measured experimentally using a custom-developed constant-head permeameter, and computationally by a poroelastic formulation to simulate the fluid flow within the discretized bone matrix and pore phase. The average of the experimentally measured permeability was 4.84 x 10(-10) m(2) with a standard deviation of 3.70 x 10(-10) m(2). A regression model of the pCT determined that the maximum bone area to total area ratio (maxBA/TA) for all slices that are perpendicular to the direction of fluid flow explained 84% of the variability of the natural logarithm of the experimentally measured permeability. The 2D measure of maxBA/TA performed better than 3D measures in general, although some parameters were reasonably well associated with permeability such as bone volume ratio (BV/TV, r=-0.71), the bone surface/bone volume (BS/BV, r=0.73), and the trabecular thickness (TbTh, r=-0.71). The correlation between the permeability predicted with FE models and experimentally measured permeability was reasonable (r=0.69), but the FE approach did not accurately represent the wide variability of permeability measured experimentally. The results of this study suggest that the changes in the trabecular bone microarchitecture have an exponential relationship with permeability, and the use of ACT-based 2D measurement of maxBA/TA performs well at predicting permeability, thus providing a convenient approach to measure this important aspect affecting biomechanical functions in the tissue. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:3129 / 3134
页数:6
相关论文
共 50 条
  • [41] Dual-energy computed tomography and micro-computed tomography for assessing bone regeneration in a rabbit tibia model
    Su, Danyang
    Wu, Yan
    Yang, Shenyu
    Ma, Duoshan
    Zhang, Haoran
    Ma, Yuanbo
    Liu, Jinlong
    Wang, Chunyu
    Liu, Huilong
    Yang, Xiaopeng
    SCIENTIFIC REPORTS, 2024, 14 (01)
  • [42] Diffraction enhanced imaging of articular cartilage and comparison with micro-computed tomography of the underlying bone structure
    Majumdar, S
    Issever, AS
    Burghardt, A
    Lotz, J
    Arfelli, F
    Rigon, L
    Heitner, G
    Menk, RH
    EUROPEAN RADIOLOGY, 2004, 14 (08) : 1440 - 1448
  • [43] Diffraction enhanced imaging of articular cartilage and comparison with micro-computed tomography of the underlying bone structure
    Sharmila Majumdar
    Ahi Sema Issever
    Andrew Burghardt
    Jeffrey Lotz
    Fulvia Arfelli
    Luigi Rigon
    Gabriele Heitner
    Ralf-Hendrik Menk
    European Radiology, 2004, 14 : 1440 - 1448
  • [44] Microarchitecture of rabbit mandibular defects grafted with intramembranous or endochondral bone shown by micro-computed tomography
    Lu, M
    Rabie, ABM
    BRITISH JOURNAL OF ORAL & MAXILLOFACIAL SURGERY, 2003, 41 (06) : 385 - 391
  • [45] Micro-Computed Tomography Analysis Methods to Assess Sheep Cancellous Bone Preservation
    Calton, E. F.
    Lukashova, L.
    Boskey, A. L.
    2010 IEEE 36TH ANNUAL NORTHEAST BIOENGINEERING CONFERENCE, 2010,
  • [46] Micro-computed tomography prediction of biomechanical strength in murine structural bone grafts
    Reynolds, David G.
    Hock, Colleen
    Shaikh, Saad
    Jacobson, Justin
    Zhang, Xinping
    Rubery, Paul T.
    Beck, Christopher A.
    O'Keefe, Regis J.
    Lerner, Amy L.
    Schwarz, Edward M.
    Awad, Hani A.
    JOURNAL OF BIOMECHANICS, 2007, 40 (14) : 3178 - 3186
  • [47] Effect of micro-computed tomography reconstruction protocols on bone fractal dimension analysis
    Gaeta-Araujo, Hugo
    Oliveira-Santos, Nicolly
    Brasil, Danieli Moura
    Leandro do Nascimento, Eduarda Helena
    Madlum, Daniela Verardi
    Haiter-Neto, Francisco
    de Oliveira-Santos, Christiano
    DENTOMAXILLOFACIAL RADIOLOGY, 2019, 48 (08)
  • [48] Subchondral bone micro-architectural alterations in osteoarthritis: a synchrotron micro-computed tomography study
    Chappard, C
    Peyrin, F
    Bonnassie, A
    Lemineur, G
    Brunet-Imbault, B
    Lespessailles, E
    Benhamou, CL
    OSTEOARTHRITIS AND CARTILAGE, 2006, 14 (03) : 215 - 223
  • [49] Three-dimensional bone modeling of forelimb joints in New Zealand Rabbit: A Micro-Computed Tomography study
    Akgun, Remzi Orkun
    Orhan, Ismail Onder
    Ekim, Okan
    ANKARA UNIVERSITESI VETERINER FAKULTESI DERGISI, 2021, 68 (04): : 355 - 363
  • [50] Mechanical stimuli of trabecular bone in osteoporosis: A numerical simulation by finite element analysis of microarchitecture
    Sandino, Clara
    McErlain, David D.
    Schipilow, John
    Boyd, Steven K.
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2017, 66 : 19 - 27