摘要
The intrinsic permeability of bone plays an important role in the transport of nutrients and minerals within the tissue, and affects the mechanical stimuli that are related to the fate of the stem cells. The objective of this study was to establish a method to assess trabecular bone permeability using experimental and finite element (FE) modeling approaches based on micro computed tomography (mu CT) images. Human cadaveric tibia cube specimens (N=23) were scanned with gCT. The permeability was measured experimentally using a custom-developed constant-head permeameter, and computationally by a poroelastic formulation to simulate the fluid flow within the discretized bone matrix and pore phase. The average of the experimentally measured permeability was 4.84 x 10(-10) m(2) with a standard deviation of 3.70 x 10(-10) m(2). A regression model of the pCT determined that the maximum bone area to total area ratio (maxBA/TA) for all slices that are perpendicular to the direction of fluid flow explained 84% of the variability of the natural logarithm of the experimentally measured permeability. The 2D measure of maxBA/TA performed better than 3D measures in general, although some parameters were reasonably well associated with permeability such as bone volume ratio (BV/TV, r=-0.71), the bone surface/bone volume (BS/BV, r=0.73), and the trabecular thickness (TbTh, r=-0.71). The correlation between the permeability predicted with FE models and experimentally measured permeability was reasonable (r=0.69), but the FE approach did not accurately represent the wide variability of permeability measured experimentally. The results of this study suggest that the changes in the trabecular bone microarchitecture have an exponential relationship with permeability, and the use of ACT-based 2D measurement of maxBA/TA performs well at predicting permeability, thus providing a convenient approach to measure this important aspect affecting biomechanical functions in the tissue. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:3129 / 3134
页数:6
相关论文
共 50 条
  • [31] Strain-adaptive in silico modeling of bone adaptation - A computer simulation validated by in vivo micro-computed tomography data
    Schulte, Friederike A.
    Zwahlen, Alexander
    Lambers, Floor M.
    Kuhn, Gisela
    Ruffoni, Davide
    Betts, Duncan
    Webster, Duncan J.
    Mueller, Ralph
    BONE, 2013, 52 (01) : 485 - 492
  • [32] Quantitative assessment of bone tissue mineralization with polychromatic micro-computed tomography
    Burghardt, Andrew J.
    Kazakia, Galateia J.
    Laib, Andres
    Majumdar, Sharmila
    CALCIFIED TISSUE INTERNATIONAL, 2008, 83 (02) : 129 - 138
  • [33] Alternative approach to assessment of bone quality using micro-computed tomography
    Hanson, NA
    Bagi, CM
    BONE, 2004, 35 (01) : 326 - 333
  • [34] Definition of the Region of Interest for the Assessment of Alveolar Bone Repair Using Micro-computed Tomography
    Borges, Juliana Simeao
    Costa, Vitor Cardoso
    Irie, Milena Suemi
    de Rezende Barbosa, Gabriella Lopes
    Spin-Neto, Rubens
    Ferreira Soares, Priscilla Barbosa
    JOURNAL OF DIGITAL IMAGING, 2023, 36 (01) : 356 - 364
  • [35] Quantitative Assessment of Bone Tissue Mineralization with Polychromatic Micro-Computed Tomography
    Andrew J. Burghardt
    Galateia J. Kazakia
    Andres Laib
    Sharmila Majumdar
    Calcified Tissue International, 2008, 83
  • [36] Comparison of the ossification centre images between standard computed tomography and micro-computed tomography
    Wang, W.
    Wang, X.
    Ren, X.
    Chen, L.
    Li, Z.
    Li, X.
    Zhang, P.
    Gao, J.
    Su, B.
    Zhang, S.
    FOLIA MORPHOLOGICA, 2020, 79 (01) : 141 - 147
  • [37] Three dimensional modeling and quantitative analysis of long bone parameters of rabbit using micro-computed tomography
    Bakici, C.
    Akgun, R. O.
    Ekim, O.
    Batur, B.
    Bakici, M.
    Ozen, D.
    Soydal, C.
    IRANIAN JOURNAL OF VETERINARY RESEARCH, 2021, 22 (02) : 140 - 145
  • [38] Micro-architecture study of the normal odontoid with micro-computed tomography
    Wang, Wei
    Li, Zhijun
    Qi, Yingna
    Chen, Lianxiang
    Yi, Ping
    Yang, Feng
    Tang, Xiangsheng
    Tan, Mingsheng
    JOURNAL OF SPINAL CORD MEDICINE, 2020, 43 (02) : 211 - 216
  • [39] Three-dimensional analysis of nonhuman primate trabecular architecture using micro-computed tomography
    Fajardo, RJ
    Müller, R
    AMERICAN JOURNAL OF PHYSICAL ANTHROPOLOGY, 2001, 115 (04) : 327 - 336
  • [40] A method for fracture toughness measurement in trabecular bone using computed tomography, image correlation and finite element methods
    Yan, Liye
    Cinar, Ahmet
    Ma, Shaocheng
    Abel, Richard
    Hansen, Ulrich
    Marrow, Thomas James
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2020, 109