Microtube-based electrode arrays for low invasive extracellular recording with a high signal-to-noise ratio

被引:12
作者
Takei, Kuniharu [1 ]
Kawano, Takeshi [1 ]
Kawashima, Takahiro [2 ]
Sawada, Kazuaki [1 ]
Kaneko, Hidekazu [3 ]
Ishida, Makoto [1 ]
机构
[1] Toyohashi Univ Technol, Dept Elect & Elect Engn, Aichi 4418580, Japan
[2] Toyohashi Univ Technol, Dept Prod Syst Engn, Aichi 4418580, Japan
[3] Natl Inst Adv Ind Sci & Technol, Tsukuba, Ibaraki 3058566, Japan
基金
日本科学技术振兴机构;
关键词
Microtube; Microneedle; Array; Extracellular recording; Low invasiveness; High signal-to-noise ratio; METAL-OXIDE-SEMICONDUCTOR; MICROELECTRODE ARRAYS; BRAIN-TISSUE; SI(111); GROWTH; IMPROVEMENT; INTERFACES; DEVICES;
D O I
10.1007/s10544-009-9356-y
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We report on the development of a microtube electrode array as a neural interface device. To combine the desired properties for the neural interface device, such as low invasiveness with a small needle and a good signal-to-noise ratio in neural recordings, we applied the structure of a glass pipette electrode to each microtube electrode. The device was fabricated as sub-5-mu m-diameter out-of-plane silicon dioxide microtube arrays using silicon microneedle templates, which are grown by the selective vapor-liquid-solid method. The microtubes had inner diameters of 1.9-6.4 mu m and a length of 25 mu m. Impedances ranged from 220 k Omega to 1.55 M Omega, which are less than those for conventional microneedles. In addition, the microtube electrodes had less signal attenuation than conventional microneedle electrodes. We confirmed that the effects of parasitic capacitances between neighboring microtubes and channels were sufficiently small using a test signal. Finally, neural responses evoked from a rat peripheral nerve were recorded in vivo using a microtube electrode to confirm that this type of electrode can be used for both electrophysiological measurements and as a neural interface device.
引用
收藏
页码:41 / 48
页数:8
相关论文
共 23 条
  • [1] Neuronal cell loss accompanies the brain tissue response to chronically implanted silicon microelectrode arrays
    Biran, R
    Martin, DC
    Tresco, PA
    [J]. EXPERIMENTAL NEUROLOGY, 2005, 195 (01) : 115 - 126
  • [2] A SILICON-BASED, 3-DIMENSIONAL NEURAL INTERFACE - MANUFACTURING PROCESSES FOR AN INTRACORTICAL ELECTRODE ARRAY
    CAMPBELL, PK
    JONES, KE
    HUBER, RJ
    HORCH, KW
    NORMANN, RA
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1991, 38 (08) : 758 - 768
  • [3] Implantable microscale neural interfaces
    Cheung, Karen C.
    [J]. BIOMEDICAL MICRODEVICES, 2007, 9 (06) : 923 - 938
  • [4] FACTORS INFLUENCING THE BIOCOMPATIBILITY OF INSERTABLE SILICON MICROSHAFTS IN CEREBRAL-CORTEX
    EDELL, DJ
    TOI, VV
    MCNEIL, VM
    CLARK, LD
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1992, 39 (06) : 635 - 643
  • [5] Primate reaching cued by multichannel spatiotemporal cortical microstimulation
    Fitzsimmons, N. A.
    Drake, W.
    Hanson, T. L.
    Lebedev, M. A.
    Nicolelis, M. A. L.
    [J]. JOURNAL OF NEUROSCIENCE, 2007, 27 (21) : 5593 - 5602
  • [6] Criteria for the selection of materials for implanted electrodes
    Geddes, LA
    Roeder, R
    [J]. ANNALS OF BIOMEDICAL ENGINEERING, 2003, 31 (07) : 879 - 890
  • [7] Neuronal ensemble control of prosthetic devices by a human with tetraplegia
    Hochberg, Leigh R.
    Serruya, Mijail D.
    Friehs, Gerhard M.
    Mukand, Jon A.
    Saleh, Maryam
    Caplan, Abraham H.
    Branner, Almut
    Chen, David
    Penn, Richard D.
    Donoghue, John P.
    [J]. NATURE, 2006, 442 (7099) : 164 - 171
  • [8] Improvement of metal-oxide semiconductor interface characteristics in complementary metal-oxide semiconductor on Si(111) by combination of fluorine implantation and long-time hydrogen annealing
    Kato, Y
    Takao, H
    Sawada, K
    Ishida, M
    [J]. JAPANESE JOURNAL OF APPLIED PHYSICS PART 2-LETTERS & EXPRESS LETTERS, 2006, 45 (4-7): : L108 - L110
  • [9] The characteristic improvement of Si (111) metal-oxide-semiconductor field-effect transistor by long-time hydrogen annealing
    Kato, Y
    Takao, H
    Sawada, K
    Ishida, M
    [J]. JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS BRIEF COMMUNICATIONS & REVIEW PAPERS, 2004, 43 (10): : 6848 - 6853
  • [10] Selective vapor-liquid-solid epitaxial growth of micro-SI probe electrode arrays with on-chip MOSFETs on Si(111) substrates
    Kawano, T
    Kato, Y
    Tani, R
    Takao, H
    Sawada, K
    Ishida, M
    [J]. IEEE TRANSACTIONS ON ELECTRON DEVICES, 2004, 51 (03) : 415 - 420