64-section multidetector CT angiography for evaluation of intracranial aneurysms: comparison with 3D rotational angiography

被引:18
作者
Li, Qi [1 ,2 ]
Lv, Fajin
Yao, Guoen [3 ]
Li, Yongmei [2 ]
Xie, Peng [1 ]
机构
[1] Chongqing Med Univ, Affiliated Hosp 1, Dept Neurol, Chongqing 400016, Peoples R China
[2] Chongqing Med Univ, Affiliated Hosp 1, Dept Radiol, Chongqing 400016, Peoples R China
[3] Third Mil Med Univ, Daping Hosp, Dept Neurol, Chongqing, Peoples R China
基金
中国国家自然科学基金;
关键词
CT angiography; intracranial aneurysm; rotational angiography; DIGITAL-SUBTRACTION-ANGIOGRAPHY; COMPUTERIZED-TOMOGRAPHY ANGIOGRAPHY; SUBARACHNOID HEMORRHAGE; CEREBRAL ANEURYSMS; MICROANEURYSMS; SURGERY; 2D;
D O I
10.1177/0284185113506138
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: To assess the diagnostic performance of 64-section computed tomography angiography (CTA) for detection of cerebral aneurysms by comparison with the new gold standard three-dimensional (3D) digital subtraction angiography (DSA). Material and Methods: A total of 128 patients who underwent both 64-section CTA and 3D DSA for suspected intracranial aneurysms were included. The location, size, and shape of the aneurysm were assessed and compared with 3D DSA results. The sensitivity, specificity, positive and negative predictive values of 64-section CTA were calculated by using 3D DSA as reference standard. Results: According to the reference standard, a total of 145 aneurysms were detected at 3D DSA in 118 patients. Of these 145 aneurysms, 64-section CTA detected 139 aneurysms in 118 patients. The sensitivity of CTA for detection of aneurysm was 95.8% on a per-aneurysm basis. All missed aneurysms were non-causative very small aneurysms in patients harboring multiple aneurysms. On a per-patient basis, the sensitivity, specificity, positive and negative predictive values were 100%. Conclusion: Compared with the new gold standard 3D DSA, 64-section CTA offers high sensitivity and specificity for detection of intracranial aneurysms. It could be readily used as a screening imaging method for detection of intracranial aneurysms.
引用
收藏
页码:840 / 846
页数:7
相关论文
共 50 条
  • [21] Dynamic evaluation of unruptured intracranial aneurysms by 4D-CT angiography: comparison with digital subtraction angiography (DSA) and surgical findings
    Yang, Liping
    Gao, Xing
    Gao, Chao
    Xu, Shichuan
    Cao, Shaodong
    BMC MEDICAL IMAGING, 2023, 23 (01)
  • [22] Detection of intracranial aneurysms with multislice CT: comparison with conventional angiography
    S. Dammert
    T. Krings
    W. Moller-Hartmann
    E. Ueffing
    F. J. Hans
    K. Willmes
    M. Mull
    A. Thron
    Neuroradiology, 2004, 46 : 427 - 434
  • [23] Detection of intracranial aneurysms with multislice CT: comparison with conventional angiography
    Dammert, S
    Krings, T
    Moller-Hartmann, W
    Ueffing, E
    Hans, FJ
    Willmes, K
    Mull, M
    Thron, A
    NEURORADIOLOGY, 2004, 46 (06) : 427 - 434
  • [24] Detection of intracranial aneurysms using three-dimensional multidetector-row CT angiography: Is bone subtraction necessary?
    Hwang, Seung Bae
    Kwak, Hyo Sung
    Han, Young Min
    Chung, Gyung Ho
    EUROPEAN JOURNAL OF RADIOLOGY, 2011, 79 (02) : E18 - E23
  • [25] Detection and evaluation of intracranial aneurysms with 16-row multislice CT angiography: Comparison with conventional angiography
    Uysal E.
    Oztora F.
    Ozel A.
    Erturk S.M.
    Yıldırım H.
    Basak M.
    Emergency Radiology, 2008, 15 (5) : 311 - 316
  • [26] Three-dimensional rotational angiography for craniotomy planning and postintervention evaluation of intracranial aneurysms
    Pedicelli, A.
    Desiderio, F.
    Esposito, G.
    Rollo, M.
    Albanese, A.
    Verdolotti, T.
    D'Argento, F.
    Bonomo, L.
    Maira, G.
    Colosimo, C.
    RADIOLOGIA MEDICA, 2013, 118 (03): : 415 - 430
  • [27] 64 Multidetector CT angiography in preoperative evaluation of hepatic artery
    El-Badrawy, Adel
    Denewer, Adel
    Kandiel, Tharwat
    Roshdy, Sameh
    El-Etreby, Shahira
    El-Badrawy, El-Said
    Shawky, Jihan
    EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE, 2011, 42 (02) : 133 - 137
  • [28] Three-dimensional rotational angiography for craniotomy planning and postintervention evaluation of intracranial aneurysms
    Pedicelli, A.
    Desiderio, F.
    Esposito, G.
    Rollo, M.
    Albanese, A.
    Verdolotti, T.
    D'Argento, F.
    Bonomo, L.
    Maira, G.
    Colosimo, C.
    RADIOLOGIA MEDICA, 2013, 118 (03): : 415 - 430
  • [29] Intra- and inter-observer variability in intracranial aneurysm segmentation: comparison between CT angiography (semi-automated segmentation software stroke VCAR) and digital subtraction angiography (3D rotational angiography)
    D'Argento, F.
    Pedicelli, A.
    Ciardi, C.
    Leone, E.
    Scarabello, M.
    Infante, A.
    Alexandre, A.
    Lozupone, E.
    Valente, I.
    Colosimo, C.
    RADIOLOGIA MEDICA, 2021, 126 (03): : 484 - 493
  • [30] Use of the stereoscopic virtual reality display system for the detection and characterization of intracranial aneurysms: A Icomparison with conventional computed tomography workstation and 3D rotational angiography
    Liu, Xiujuan
    Tao, Haiquan
    Xiao, Xigang
    Guo, Binbin
    Xu, Shangcai
    Sun, Na
    Li, Maotong
    Xie, Li
    Wu, Changjun
    CLINICAL NEUROLOGY AND NEUROSURGERY, 2018, 170 : 93 - 98