The Comparison of Automated Silver in situ Hybridization and Fluorescence in situ Hybridization for Evaluating HER2 Gene Amplification in Breast Carcinoma

被引:6
|
作者
Kim, Tae-Jung [1 ]
Kim, Tae Eun [1 ]
Jung, Eun Sun [1 ]
Yim, Hyeon Woo [2 ]
Song, Byung Joo [3 ]
Jung, Sang Seol [3 ]
Lee, Ahwon [1 ]
Choi, Yeong-Jin [1 ]
Lee, Kyo-Young [1 ]
机构
[1] Catholic Univ Korea, Coll Med, Dept Pathol, Seoul, South Korea
[2] Catholic Univ Korea, Coll Med, Dept Prevent Med, Seoul, South Korea
[3] Catholic Univ Korea, Coll Med, Dept Surg, Seoul, South Korea
关键词
Breast neoplasms; Fluorescence in situ hybridization; Immunohistochemistry; Silver in situ hybridization; ANTI-HER2; MONOCLONAL-ANTIBODY; OF-CLINICAL-ONCOLOGY; ONCOGENE; THERAPY; PROTEIN; CANCER; SISH;
D O I
10.4048/jbc.2009.12.4.295
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: We want to validate the use of the silver-enhanced in situ hybridization (SISH) technique as comparised with fluorescence in situ hybridization (FISH) technique for assessing the HER2 gene amplification of breast carcinoma. Methods: Tissue microarray (TMA) blocks from 58 breast cancer specimens were prepared and the concordance between HER2 gene amplification in breast cancer was determined by the FISH (PathVysion (R), Abbot/Vysis) technique and the automated silver in situ hybridization (SISH, INFORM (TM), Ventana) technique. For comparison, all the specimens were stained by immunohistochemistry (Ventana-PATHWAY (R) 4B5). Evaluation was performed by two pathologists and with following the instructions of the manufacturers and the guidelines of the American Society of Clinical Oncology/College of American Pathologists. Results: The results of SISH and FISH were identical in all 58 cases; 17 cases showed HER2 amplification, and on the other hand, 41 cases didn't show HER2 amplification. Five weakly positive (2+) cases in immunohistochemistry staining revealed one HER2 amplification and four no HER2 amplification on both SISH and FISH. The SISH results of the HER2/CEP17 ratio were well correlated with the FISH results of the HER2/CEP17 ratio (correlation coefficient r=0.745, Linear regression r(2)=0.555, p<0.001). Conclusion: The results of the SISH technique for assessing the HER2 status of excised breast carcinoma is comparable to the result obtained by FISH. However, SISH has the advantage of having permanent end result that can be visualized by an ordinary light microscope and less laborious preparation and time is needed than is required by FISH. SISH seems to be more feasible than FISH for assessing HER2 amplification of breast cancer.
引用
收藏
页码:295 / 301
页数:7
相关论文
共 50 条
  • [31] Performance of Automated Brightfield Dual Color In Situ Hybridization (ISH) for Detection of HER2 Gene Amplification in Breast Carcinoma
    Nitta, H.
    Hauss-Wegrzyniak, B.
    Lehrkamp, M.
    Murillo, A.
    Farrell, M.
    Kurosumi, M.
    Walk, E.
    Dietel, M.
    Penault-Llorca, F.
    Loftus, M.
    Wang, L.
    Pettay, J.
    Tubbs, R.
    Grogan, T.
    MODERN PATHOLOGY, 2009, 22 : 60A - 60A
  • [32] Performance of Automated Brightfield Dual Color In Situ Hybridization (ISH) for Detection of HER2 Gene Amplification in Breast Carcinoma
    Nitta, H.
    Hauss-Wegrzyniak, B.
    Lehrkamp, M.
    Murillo, A.
    Farrell, M.
    Kurosumi, M.
    Walk, E.
    Dietel, M.
    Penault-Llorca, F.
    Loftus, M.
    Wang, L.
    Pettay, J.
    Tubbs, R.
    Grogan, T.
    LABORATORY INVESTIGATION, 2009, 89 : 60A - 60A
  • [33] Effect of fixation period on HER2/neu gene amplification detected by fluorescence in situ hybridization in invasive breast carcinoma
    Selvarajan, S
    Bay, BH
    Choo, A
    Chuah, KL
    Sivaswaren, CR
    Tien, SL
    Wong, CY
    Tan, PH
    JOURNAL OF HISTOCHEMISTRY & CYTOCHEMISTRY, 2002, 50 (12) : 1693 - 1696
  • [34] Comparative Assessment of Immunohistochemistry (IHC), Fluorescence In Situ Hybridization (FISH), and Silver-Enhanced In Situ Hybridization (SISH) for Evaluation of HER2 Gene Status in Breast Carcinoma
    Ryu, Y.
    Jeong, H.
    Kim, Y.
    Kim, B.
    Kim, H.
    Kim, A.
    MODERN PATHOLOGY, 2010, 23 : 70A - 70A
  • [35] Comparative Assessment of Immunohistochemistry (IHC), Fluorescence In Situ Hybridization (FISH), and Silver-Enhanced In Situ Hybridization (SISH) for Evaluation of HER2 Gene Status in Breast Carcinoma
    Ryu, Y.
    Jeong, H.
    Kim, Y.
    Kim, B.
    Kim, H.
    Kim, A.
    LABORATORY INVESTIGATION, 2010, 90 : 70A - 70A
  • [36] HER2 amplification: Correlation of chromogenic in situ hybridization (CISH) with inummohistochemistry (IHC) and fluorescence in situ hybridization (FISH)
    Wixom, CR
    Albers, EA
    Weidner, N
    MODERN PATHOLOGY, 2003, 16 (01) : 51A - 51A
  • [37] HER2 amplification: Correlation of chromogenic in situ hybridization (CISH) with immunohistochemistry (IHC) and fluorescence in situ hybridization (FISH)
    Wixom, CR
    Albers, EA
    Weidner, N
    LABORATORY INVESTIGATION, 2003, 83 (01) : 51A - 51A
  • [38] Automated detection of the HER2 gene amplification status in Fluorescence in situ hybridization images for the diagnostics of cancer tissues
    Falk Zakrzewski
    Walter de Back
    Martin Weigert
    Torsten Wenke
    Silke Zeugner
    Robert Mantey
    Christian Sperling
    Katrin Friedrich
    Ingo Roeder
    Daniela Aust
    Gustavo Baretton
    Pia Hönscheid
    Scientific Reports, 9
  • [39] Discordant HER2 Immunohistochemical Expression and Gene Amplification by In-Situ Hybridization in Ductal Carcinoma In Situ
    Wang, Hai
    Hui, Yiang
    Resnick, Murray B.
    Wang, Yihong
    MODERN PATHOLOGY, 2017, 30 : 77A - 77A
  • [40] Discordant HER2 Immunohistochemical Expression and Gene Amplification by In-Situ Hybridization in Ductal Carcinoma In Situ
    Wang, Hai
    Hui, Nang
    Resnick, Murray B.
    Wang, Yihong
    LABORATORY INVESTIGATION, 2017, 97 : 77A - 77A