The impact of wood stove technology upgrades on indoor residential air quality

被引:40
作者
Allen, Ryan W. [1 ]
Leckie, Sara [2 ]
Millar, Gail [3 ]
Brauer, Michael [2 ]
机构
[1] Simon Fraser Univ, Fac Hlth Sci, Burnaby, BC V5A 1S6, Canada
[2] Univ British Columbia, Sch Environm Hlth, Vancouver, BC V5Z 1M9, Canada
[3] Univ No British Columbia, Dept Environm Sci & Engn, Prince George, BC V2L 5P2, Canada
关键词
Wood stove; Intervention; Particulate matter; Levoglucosan; Infiltration; FINE PARTICULATE MATTER; EMERGENCY ROOM VISITS; LIGHT-SCATTERING DATA; LUNG-FUNCTION; COMBUSTION; POLLUTION; ASTHMA; CHILDREN; SEATTLE; EXPOSURE;
D O I
10.1016/j.atmosenv.2009.08.016
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Fine particulate matter (PM(2.5)) air pollution has been linked to adverse health impacts, and combustion sources including residential wood-burning may play an-important role in some regions. Recent evidence suggests that indoor air quality may improve in homes where older, non-certified wood stoves are exchanged for lower emissions EPA-certified alternatives. As part of a wood stove exchange program in northern British Columbia, Canada, we sampled outdoor and indoor air at 15 homes during 6-day sampling sessions both before and after non-certified wood stoves were exchanged. During each sampling session two consecutive 3-day PM(2.5) Samples were collected onto Teflon filters, which were weighed and analyzed for the wood smoke tracer levoglucosan. Residential PM(2.5) infiltration efficiencies (F(inf)) were estimated from continuous light scattering measurements made with nephelometers, and estimates of F(inf) were used to calculate the outdoor- and indoor-generated contributions to indoor air. There was not a consistent relationship between stove technology and outdoor or indoor concentrations of PM(2.5) or levoglucosan. Mean F(inf) estimates were low and similar during pre- and post-exchange periods (0.32 +/- 0.17 and 0.33 +/- 0.17, respectively). Indoor sources contributed the majority (similar to 65%) of the indoor PM(2.5) concentrations, independent of stove technology, although low indoor-outdoor levoglucosan ratios (median <= 0.19) and low indoor PM(2.5)-levoglucosan correlations (r <= 0.19) suggested that wood smoke was not a major indoor PM(2.5) source in most of these homes. In summary, despite the potential for extensive wood stove exchange programs to reduce outdoor PM(2.5) concentrations in wood smoke-impacted communities, we did not find a consistent relationship between stove technology upgrades and indoor air quality improvements in homes where stoves were exchanged. (C) 2009 Elsevier Ltd. All rights reserved.
引用
收藏
页码:5908 / 5915
页数:8
相关论文
共 50 条
  • [31] Evaluation of indoor air quality in high-rise residential buildings in Bangkok and factor analysis
    Phongphetkul, Phetcharin
    Mangkang, Sirapach
    Praditsmanont, Apichat
    Intrachooto, Singh
    Choruengwiwat, Jittapat
    Treesubsuntorn, Chairat
    Thiravetyan, Paitip
    ENVIRONMENTAL MONITORING AND ASSESSMENT, 2021, 193 (01)
  • [32] Enhancing indoor air quality and cardiopulmonary health in patients with asthma by photocatalytic oxidation and filters air cleaner
    Zhang, Jia Lin
    Liao, Guan-Yu
    Lin, Hong-Yi
    Xie, Jie-An
    Li, Wan-Chen
    Chen, Huang-Chi
    Wu, Da Wei
    Juan, Huai-Lei
    Kuo, Jia-Yu
    Chen, Pei-Shih
    JOURNAL OF HAZARDOUS MATERIALS, 2025, 482
  • [33] Investigation on Indoor Air Quality in Tianjin Residential Buildings
    Sun, Yuexia
    Cheng, Rongsai
    Hou, Jing
    Song, Yangrui
    Luo, Shugang
    10TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING, ISHVAC2017, 2017, 205 : 3811 - 3815
  • [34] Indoor pollution and burning practices in wood stove management
    Piccardo, M. T.
    Cipolla, M.
    Stella, A.
    Ceppi, M.
    Bruzzone, M.
    Izzotti, A.
    Valerio, F.
    JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 2014, 64 (11) : 1309 - 1316
  • [35] Biomarkers and indoor air quality: A translational research review
    Senerat, Araliya M.
    Manemann, Sheila M.
    Clements, Nicholas S.
    Brook, Robert D.
    Hassett, Leslie C.
    Roger, Veronique L.
    JOURNAL OF CLINICAL AND TRANSLATIONAL SCIENCE, 2021, 5 (01)
  • [36] Impact of kerosene space heaters on indoor air quality
    Hanoune, B.
    Carteret, M.
    CHEMOSPHERE, 2015, 134 : 581 - 587
  • [37] Wildfire Impact on Indoor and Outdoor PAH Air Quality
    Ghetu, Christine C.
    Rohlman, Diana
    Smith, Brian W.
    Scott, Richard P.
    Adams, Kaley A.
    Hoffman, Peter D.
    Anderson, Kim A.
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2022, 56 (14) : 10042 - 10052
  • [38] Measurements and assessment of indoor thermal environment with a wood stove
    Yonezawa S.
    Mae M.
    Miura H.
    Akamine Y.
    Takase K.
    Fukanoki T.
    2016, Architectural Institute of Japan (22) : 171 - 176
  • [39] Indoor air quality in Latino homes in Boulder, Colorado
    Escobedo, Luis E.
    Champion, Wyatt M.
    Li, Ning
    Montoya, Lupita D.
    ATMOSPHERIC ENVIRONMENT, 2014, 92 : 69 - 75
  • [40] Field study on indoor air quality of wood remodeled welfare facilities for physical and psychological benefits
    Cho, Hyun Mi
    Lee, Jongki
    Wi, Seunghwan
    Kim, Sumin
    JOURNAL OF CLEANER PRODUCTION, 2019, 233 : 197 - 208