Dynamic magnetic resonance imaging of endoscopic third ventriculostomy patency with differently acquired fast imaging with steady-state precession sequences

被引:5
|
作者
Lucic, Milos A. [1 ]
Koprivsek, Katarina [1 ]
Kozic, Dusko [1 ]
Spero, Martina [2 ]
Spirovski, Milena [1 ]
Lucic, Silvija [1 ]
机构
[1] Univ Novi Sad, Diagnost Imaging Ctr, Oncol Inst Vojvodina, Fac Med, Novi Sad 21204, Serbia
[2] Univ Zagreb, Univ Hosp Dubrava, Dept Radiol, Zagreb, Croatia
关键词
magnetic resonance imaging; dynamic magnetic resonance imaging; fast imaging with steady state precession; cerebrospinal fluid flow; endoscopic third ventriculostomy; CEREBROSPINAL-FLUID FLOW; VENTRICULOPERITONEAL SHUNT; OBSTRUCTIVE HYDROCEPHALUS; CSF FLOW; CHILDREN; SIZE; MOTION;
D O I
10.17305/bjbms.2014.3.37
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
The aim of the study was to determine the possibilities of two differently acquired two-dimensional fast imaging with steady-state precession (FISP 2D) magnetic resonance sequences in estimation of the third ventricle floor fenestration patency after endoscopic third ventriculostomy (ETV) in the subjects with aqueductal stenosis/obstruction. Fifty eight subjects (37 males, 21 females, mean age 27 years) with previously successfully performed ETV underwent brain MRI on 1.5T MR imager 3-6 months after the procedure. Two different FISP 2D sequences (one included in the standard vendor provided software package, and the other, experimentally developed by our team) were performed respectively at two fixed slice positions: midsagittal and perpendicular to the ETV fenestration, and displayed in a closed-loop cinematographic format in order to estimate the patency. The ventricular volume reduction has been observed as well. Cerebrospinal fluid (CSF) flow through the ETV fenestration was observed in midsagittal plane with both FISP 2D sequences in 93.11% subjects, while in 6.89% subjects the dynamic CSF flow MRI was inconclusive. In the perpendicular plane CSF flow through the ETV fenestration was visible only by use of experimentally developed FISP 2D (TR30/FA70) sequence. Postoperative volume reduction of lateral and third ventricle was detected in 67.24% subjects. Though both FISP 2D sequences acquired in midsagittal plane may be used to estimate the effects of performed ETV, due to achieved higher CSF pulsatile flow sensitivity, only the use of FISP 2D (TR30/FA70) sequence enables the estimation of the treatment effect in perpendicular plane in the absence of phase-contrast sequences.
引用
收藏
页码:165 / 170
页数:6
相关论文
共 50 条
  • [1] CSF flow imaging in the management of third ventriculostomy with a reversed fast imaging with steady-state precession sequence
    Hoffmann, KT
    Lehmann, TN
    Baumann, C
    Felix, R
    EUROPEAN RADIOLOGY, 2003, 13 (06) : 1432 - 1437
  • [2] CSF flow imaging in the management of third ventriculostomy with a reversed fast imaging with steady-state precession sequence
    Karl T. Hoffmann
    Thomas N. Lehmann
    Clemens Baumann
    Roland Felix
    European Radiology, 2003, 13 : 1432 - 1437
  • [3] The Predictive Role of Early Postoperative Magnetic Resonance Imaging After Endoscopic Third Ventriculostomy
    Hidalgo, E. Teresa
    Schnurman, Zane
    Harter, David H.
    WORLD NEUROSURGERY, 2024, 189 : E331 - E346
  • [4] Three-dimensional constructive interference in steady-state magnetic resonance imaging in obstructive hydrocephalus: relevance for endoscopic third ventriculostomy and clinical results
    Kunz, Mathias
    Schulte-Altedorneburg, Gernot
    Uhl, Eberhard
    Schmid-Elsaesser, Robert
    Schoeller, Karsten
    Zausinger, Stefan
    JOURNAL OF NEUROSURGERY, 2008, 109 (05) : 931 - 938
  • [5] Analysis of endoscopic third ventriculostomy patency by MRI: value of different pulse sequences, the sequence parameters, and the imaging planes for investigation of flow void
    Dincer, Alp
    Yildiz, Erdem
    Kohan, Saeed
    Ozek, M. Memet
    CHILDS NERVOUS SYSTEM, 2011, 27 (01) : 127 - 135
  • [6] Fast interactive real-time magnetic resonance imaging of cardiac masses using spiral gradient echo and radial steady-state free precession sequences
    Spuentrup, E
    Mahnken, AH
    Kühl, HP
    Krombach, GA
    Botnar, RM
    Wall, A
    Schaeffter, T
    Günther, RW
    Buecker, A
    INVESTIGATIVE RADIOLOGY, 2003, 38 (05) : 288 - 292
  • [7] Evaluation of magnetic resonance imaging features of spontaneous third ventriculostomy in triventricular hydrocephalus
    Arslan, Serdar
    Karaman, Ahmet Kursat
    Korkmazer, Bora
    Hikmat, Emil
    Ustundag, Ahmet
    Tahmazoglu, Burak
    Kafadar, Ali Metin
    Kizilkilic, Osman
    ACTA RADIOLOGICA, 2025,
  • [8] Utility of True Fast Imaging with Steady-State Precession in Detecting Arachnoid Veils of the Posterior Fossa
    Kashanian, Alon
    Binesh, Nader
    Pressman, Barry D.
    Danielpour, Moise
    PEDIATRIC NEUROSURGERY, 2021, 56 (03) : 292 - 299
  • [9] Detection of pseudoaneurysm of the left ventricle by fast imaging employing steady-state acquisition (FIESTA) magnetic resonance Imaging
    Rerkpattanapipat, P
    Mazur, W
    Link, KM
    Clark, HP
    Hundley, WG
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2003, 5 (02) : 399 - 402
  • [10] Steady-state magnetic resonance imaging in inner ear malformations
    Manfre, L
    Lagalla, R
    Quaranta, A
    Ferrara, S
    Riggio, F
    Garribba, AP
    Ettorre, GC
    INTERNATIONAL JOURNAL OF NEURORADIOLOGY, 1997, 3 (02): : 160 - 164