A practical solid sampling method for the determination of lead in chewing gum by electrothermal atomic absorption spectrometry

被引:25
作者
Baysal, Asli [1 ]
Ozbek, Nil [1 ]
Akman, Suleyman [1 ]
机构
[1] Istanbul Tech Univ, Fac Sci & Letters, Dept Chem, TR-34469 Maslak, Turkey
关键词
Solid sampling; Lead; Atomic absorption spectrometry; Chewing gum; MANGANESE; COPPER;
D O I
10.1016/j.foodchem.2010.05.004
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
In this study, the lead concentrations of chewing gum samples having different compositions were determined by solid sampling electrothermal atomic absorption spectrometry. In order to optimise the experimental conditions, the effects of pyrolysis temperature, atomization temperature, sample amount and sample thermal pre-treatment, on the analyte sensitivity were investigated. The samples were ashed at 400 degrees C for 2 h prior to directly determined by SS-ETAAS applying 600 degrees C of pyrolysis and 1600 degrees C of atomization temperatures without to add a modifier, acid and/or surfactant. The relationship between sample mass and integrated absorbance was linear up to 1.2 mg of sample; for higher sample mass the relationship was no longer linear, irrespective of the lead content. In addition, the thermally treated chewing gum samples were digested using concentrated HNO3. The lead concentrations found by the two methods in 27 different kinds of samples were not significantly different at 95% confidence level. The proposed solid sampling technique was fast, simple, the risks of contamination and analyte loss were low. Detection limit (3 sigma) for lead was 0.017 ng/g. (C) 2010 Elsevier Ltd. All rights reserved.
引用
收藏
页码:901 / 904
页数:4
相关论文
共 11 条
[1]   Comparison of direct solid sampling and slurry sampling for the determination of cadmium in wheat flour by electrothermal atomic absorption spectrometry [J].
Araujo, Rennan G. O. ;
Oleszczuk, Nedio ;
Rampazzo, Roger T. ;
Costa, Pedro A. ;
Silva, Mdrcia M. ;
Vale, Maria Goreti R. ;
Welz, Bernhard ;
Ferreira, Sergio L. C. .
TALANTA, 2008, 77 (01) :400-406
[2]   Discrimination of the causes of imprecision in the direct determination of metals in organic solid samples by electrothermal atomization atomic absorption spectrometry [J].
Belarra, MA ;
Resano, M ;
Castillo, JR .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1998, 13 (05) :489-494
[3]   Direct determination of phosphorus in different food samples by means of solid sampling electrothermal atomic absorption spectrometry using Pd plus Ca chemical modifier [J].
Coskun, N ;
Akman, S .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2005, 60 (03) :415-419
[4]   Direct determination of manganese in vitamin-mineral tablets using solid sampling electrothermal atomic absorption spectrometry [J].
Coskun, N ;
Akman, S .
TALANTA, 2004, 64 (02) :496-500
[5]   Trace metal contents in chewing gums and candies marketed in Turkey [J].
Duran, Ali ;
Tuzen, Mustafa ;
Soylak, Mustafa .
ENVIRONMENTAL MONITORING AND ASSESSMENT, 2009, 149 (1-4) :283-289
[6]   SAMPLE PREPARATION AND THE DETERMINATION OF LEAD IN CHEWING GUM BY NONFLAME ATOMIC-ABSORPTION SPECTROMETRY [J].
FETTEROLF, DD ;
SYTY, A .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 1979, 27 (02) :377-380
[7]   Determination of lead and copper in chewing gum samples by electrothermal-flame atomic absorption spectrometry using various chemical modifiers and arsenic by hydride generation [J].
Kiliç, Z ;
Kendüzler, E ;
Acar, O .
FOOD CHEMISTRY, 2002, 77 (01) :85-92
[8]   DETERMINATION OF NICKEL, MANGANESE, COPPER, AND ALUMINUM IN CHEWING GUM BY NONFLAME ATOMIC-ABSORPTION SPECTROMETRY [J].
KUPCHELLA, L ;
SYTY, A .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 1980, 28 (05) :1035-1036
[9]  
Kurfurst U., 1998, SOLID SAMPLE ANAL DI, DOI 10.1007/978-3-662-03716-4
[10]  
*RAP AL SYST FOOD, 2003, INF AL NOT WEEK 2003