Validation of a mammographic image quality modification algorithm using 3D-printed breast phantoms

被引:6
作者
Boita, Joana [1 ,2 ]
Mackenzie, Alistair [3 ]
van Engen, Ruben E. [2 ]
Broeders, Mireille [2 ,4 ]
Sechopoulos, Ioannis [1 ,2 ]
机构
[1] Radboud Univ Nijmegen, Dept Med Imaging, Med Ctr, Nijmegen, Netherlands
[2] Dutch Expert Ctr Screening LRCB, Nijmegen, Netherlands
[3] Royal Surrey NHS Fdn Trust, Natl Coordinating Ctr Phys Mammog, Guildford, Surrey, England
[4] Radboud Univ Nijmegen, Dept Hlth Evidence, Med Ctr, Nijmegen, Netherlands
关键词
digital mammography; virtual clinical trials; image quality; image simulation; DIGITAL MAMMOGRAPHY; CANCER-DETECTION; DOSE REDUCTION; DETECTOR; DETECTABILITY; LOCALIZATION; LESIONS; IMPACT; NOISE; MASS;
D O I
10.1117/1.JMI.8.3.033502
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To validate a previously proposed algorithm that modifies a mammogram to appear as if it was acquired with different technique factors using realistic phantom-based mammograms. Approach: Two digital mammography systems (an indirect- and a direct-detector-based system) were used to acquire realistic mammographic images of five 3D-printed breast phantoms with the technique factors selected by the automatic exposure control and at various other conditions (denoted by the original images). Additional images under other simulated conditions were also acquired: higher or lower tube voltages, different anode/filter combinations, or lower tube current-time products (target images). The signal and noise in the original images were modified to simulate the target images (simulated images). The accuracy of the image modification algorithm was validated by comparing the target and simulated images using the local mean, local standard deviation (SD), local variance, and power spectra (PS) of the image signals. The absolute relative percent error between the target and simulated images for each parameter was calculated at each sub-region of interest (local parameters) and frequency (PS), and then averaged. Results: The local mean signal, local SD, local variance, and PS of the target and simulated images were very similar, with a relative percent error of 5.5%, 3.8%, 7.8%, and 4.4% (indirect system), respectively, and of 3.7%, 3.8%, 7.7%, and 7.5% (direct system), respectively. Conclusions: The algorithm is appropriate for simulating different technique factors. Therefore, it can be used in various studies, for instance to evaluate the impact of technique factors in cancer detection using clinical images. (C) 2021 Society of Photo-Optical Instrumentation Engineers (SPIE)
引用
收藏
页数:29
相关论文
共 39 条
  • [1] [Anonymous], 2005, 89 IPEM
  • [2] Reproducing two-dimensional mammograms with three-dimensional printed phantoms
    Badal, Andreu
    Clark, Matthew
    Ghammraoui, Bahaa
    [J]. JOURNAL OF MEDICAL IMAGING, 2018, 5 (03)
  • [3] Virtual Tools for the Evaluation of Breast Imaging: State-of-the Science and Future Directions
    Bakic, Predrag R.
    Myers, Kyle J.
    Glick, Stephen J.
    Maidment, Andrew D. A.
    [J]. BREAST IMAGING, IWDM 2016, 2016, 9699 : 518 - 524
  • [4] Method of simulating dose reduction for digital radiographic systems
    Båth, M
    Håkansson, M
    Tingberg, A
    Månsson, LG
    [J]. RADIATION PROTECTION DOSIMETRY, 2005, 114 (1-3) : 253 - 259
  • [5] Validation of a method to simulate the acquisition of mammographic images with different techniques
    Boita, Joana
    Mackenzie, Alistair
    Sechopoulos, Ioannis
    [J]. MEDICAL IMAGING 2019: PHYSICS OF MEDICAL IMAGING, 2019, 10948
  • [6] Breast phantom validation of a mammographic image modification method
    Boita, Joana
    Mackenzie, Alistair
    Sechopoulos, Ioannis
    [J]. 14TH INTERNATIONAL WORKSHOP ON BREAST IMAGING (IWBI 2018), 2018, 10718
  • [7] Effect of detector element size on signal detectability in digital mammography
    Burgess, AE
    [J]. MEDICAL IMAGING 2005: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2005, 5745 : 232 - 242
  • [8] DEVELOPMENT OF AN ANTHROPOMORPHIC BREAST PHANTOM
    CALDWELL, CB
    YAFFE, MJ
    [J]. MEDICAL PHYSICS, 1990, 17 (02) : 273 - 280
  • [9] The effect of scatter and glare on image quality in contrast-enhanced breast imaging using an a-Si/CsI(Tl) full-field flat panel detector
    Carton, Ann-Katherine
    Acciavatti, Raymond
    Kuo, Johnny
    Maidment, Andrew D. A.
    [J]. MEDICAL PHYSICS, 2009, 36 (03) : 920 - 928
  • [10] Observer studies involving detection and localization: Modeling, analysis, and validation
    Chakraborty, DP
    Berbaum, KS
    [J]. MEDICAL PHYSICS, 2004, 31 (08) : 2313 - 2330