First-pass myocardial perfusion cardiovascular magnetic resonance at 3 Tesla

被引:20
|
作者
Su, Mao-Yuan M.
Yang, Kai-Chien
Wu, Chau-Chung
Wu, Yen-Wen
Yu, Hsi-Yu
Tseng, Rung-Yu
Tseng, Wen-Yih I.
机构
[1] Natl Taiwan Univ, Ctr Optoelect Biomed, Coll Med, Taipei 10016, Taiwan
[2] Natl Yang Ming Univ, Inst Biomed Engn, Taipei 112, Taiwan
[3] Natl Taiwan Univ Hosp, Dept Internal Med, Taipei 100, Taiwan
[4] Natl Taiwan Univ Hosp, Dept Nucl Med, Taipei, Taiwan
[5] Natl Taiwan Univ Hosp, Dept Surg, Taipei 100, Taiwan
[6] Natl Taiwan Univ Hosp, Dept Med Imaging, Taipei, Taiwan
关键词
myocardial perfusion; 3; Tesla; ischemic heart disease;
D O I
10.1080/10976640601093661
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Purpose: To test the feasibility of first-pass contrast-enhanced myocardial perfusion imaging at 3 Tesla and to evaluate the change in perfusion index between normal, remote and ischemic myocardium, we obtained perfusion index from healthy subjects and patients with coronary artery stenosis. Materials and Methods: First-pass contrast-enhanced perfusion imaging was performed on 12 patients and 32 age-matched healthy subjects in both rest and dipyridamole-induced stress states. After bolus injection of contrast agent, Gd-DTPA with dose of 0.025 mmol/kg body weight and injection time of 1.5 s, three short-axis images from apex to base of the left ventricle (LV) were acquired for 80 cardiac cycles using saturation recovery turbo FLASH sequence. The maximal upslope (Upslope) was derived from the signal-time curves of the LV cavity and myocardium to measure myocardial perfusion. Within 72 hours after cardiovascular magnetic resonance examination, patients received coronary angiography, and the results were correlated with cardiovascular magnetic resonance results. Results: Using our protocol of contrast agent administration, sufficient perfusion contrast was obtained without susceptibility-induced signal drop-out at the interface between LV cavity and the myocardium. In healthy volunteers, Upslope showed no dependence on myocardial segments or coronary territories. Upslope increased significantly from rest to stress in normal myocardium (0.09 +/- 0.03 vs. 0.16 +/- 0.05, p < 0.001) and remote myocardium (0.09 +/- 0.03 vs. 0.13 +/- 0.03, p < 0.001), whereas in ischemic myocardium the change was insignificant (0.11 +/- 0.03 vs. 0.10 +/- 0.04, p = ns). This resulted in significant difference in the ratio of Upslope at stress to that at rest, representing myocardial perfusion reserve, between ischemic and non-ischemic myocardium (0.96 +/- 0.41 vs. 1.71 +/- 0.42, p < 0.001 for ischemic vs. normal myocardium; 0.96 +/- 0.41 vs. 1.59 +/- 0.40, p < 0.001 for ischemic vs. remote myocardium). Conclusions: First-pass gadolinium-enhanced myocardial perfusion imaging at 3 Tesla is feasible. The Upslope ratio can differentiate ischemic from non-ischemic myocardium.
引用
收藏
页码:633 / 644
页数:12
相关论文
共 50 条
  • [31] Choice of metal ion and formulation concentration for first-pass brain perfusion studies with magnetic resonance imaging at 1.5 tesla
    Runge, VM
    Wells, JW
    INVESTIGATIVE RADIOLOGY, 1996, 31 (07) : 395 - 400
  • [32] Magnetic resonance myocardial first-pass perfusion imaging: Parameter optimization for signal response and cardiac coverage
    Bertschinger, KM
    Nanz, D
    Buechi, M
    Luescher, TF
    Marincek, B
    von Schulthess, GK
    Schwitter, J
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2001, 14 (05) : 556 - 562
  • [33] Abnormally heterogeneous myocardial perfusion in syndrome X detected by first-pass magnetic resonance imaging.
    Panting, JR
    Gatehouse, PD
    Burger, P
    Grothues, F
    Firmin, DN
    Collins, PD
    Pennell, DJ
    CIRCULATION, 2000, 102 (18) : 686 - 686
  • [34] Regional myocardial perfusion abnormalities: Fractional flow reserve versus cardiac magnetic resonance first-pass perfusion imaging
    Neizel M.
    Kaestner W.
    Kelm M.
    Kühl H.P.
    Current Cardiovascular Imaging Reports, 2009, 2 (2) : 124 - 129
  • [35] Ruptured Aneurysm of the Sinus of Valsalva Insights From Magnetic Resonance First-Pass Myocardial Perfusion Imaging
    Schuster, Andreas
    Hedstroem, Erik
    Blauth, Christopher
    Marber, Michael S.
    Nagel, Eike
    Carr-White, Gerald
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 59 (05) : 538 - 538
  • [36] Steady-State First-Pass Perfusion (SSFPP): A New Approach to 3D First-Pass Myocardial Perfusion Imaging
    Giri, Shivraman
    Xue, Hui
    Maiseyeu, Andrei
    Kroeker, Randall
    Rajagopalan, Sanjay
    White, Richard D.
    Zuehlsdorff, Sven
    Raman, Subha V.
    Simonetti, Orlando P.
    MAGNETIC RESONANCE IN MEDICINE, 2014, 71 (01) : 133 - 144
  • [37] Characterization of microvascular dysfunction after acute myocardial infarction by cardiovascular magnetic resonance first-pass perfusion and late gadolinium enhancement imaging
    Yan, Andrew T.
    Gibson, C. Michael
    Larose, Eric
    Anavekar, Nagesh S.
    Tsang, Sui
    Solomon, Scott D.
    Reynolds, Glenn
    Kwong, Raymond Y.
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2006, 8 (06) : 831 - 837
  • [38] Re: Assessment of coronary microvascular dysfunction in hypertrophic cardiomyopathy: First-pass myocardial perfusion cardiovascular magnetic resonance imaging at 1.5 T
    Daniowicz-Szymanowicz, L.
    Dorniak, K.
    Szurowska, E.
    Dudziak, M.
    Raczak, G.
    CLINICAL RADIOLOGY, 2014, 69 (03) : E163 - E164
  • [39] First-pass Contrast-enhanced Myocardial Perfusion MR Imaging in Mice on a 3 Tesla Clinical MR Scanner
    Marcus, Makowski
    Jansen, Christian
    Webb, Ian
    Botnar, Rene
    Kozerke, Sebastian
    Nagel, Eike
    Plein, Sven
    CIRCULATION, 2010, 122 (21)
  • [40] Quantitative magnetic resonance first-pass perfusion analysis:: Interand intraobserver agreement
    Mühling, OM
    Dickson, ME
    Zenovich, A
    Huang, YM
    Wilson, BV
    Wilson, RF
    Anand, IS
    Seethamraju, RT
    Jerosch-Herold, M
    Wilke, NM
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2001, 3 (03) : 247 - 256