MoS2 Sphere/2D S-Ti3C2 MXene Nanocatalysts on Laser-Induced Graphene Electrodes for Hazardous Aristolochic Acid and Roxarsone Electrochemical Detection

被引:70
作者
Rajaji, Umamaheswari [1 ]
Ganesh, Pattan-Siddappa [2 ]
Kim, Sang-Youn [2 ]
Govindasamy, Mani [1 ]
Alshgari, Razan Abdullah [3 ]
Liu, Ting-Yu [1 ]
机构
[1] Ming Chi Univ Technol, Dept Mat Engn, New Taipei 243303, Taiwan
[2] Korea Univ Technol & Educ, Future Convergence Engn, Adv Technol Res Ctr, Interact Lab, Cheonan Si 31253, Chungcheongnam, South Korea
[3] King Saud Univ, Coll Sci, Chem Dept, Riyadh 11451, Saudi Arabia
关键词
MXenes; simultaneous electrochemical sensors; binary electrocatalyst; aristolochic acid; roxarsone antibiotics; ULTRASENSITIVE DETECTION; TI3C2TX MXENE; CARBIDE MXENE; NANOSHEETS; PLATFORM;
D O I
10.1021/acsanm.1c03680
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
As nanomaterials have a high surface-to-volume ratio, they have very specific features and therefore can be employed in a variety of applications. The development of electrochemical sensors based on novel nanocatalysts for detecting hazardous compounds is a primary concern. In the present work, we have proposed a novel synthesis protocol for a MoS2 sphere-combined sulfur-doped Ti3C2 MXene nanocatalyst (MoS2/S-Ti3C2) and evaluated its electrochemical sensing performance. The structural characterization of this novel nanocatalyst revealed that it was successfully synthesized using a hydrothermal process. In addition, the electrochemical activity of different quantities of the MoS2/S-Ti3C2 nanocatalyst loaded onto a laser-induced graphene electrode (LGE) was investigated, and it was discovered that 8 mu L of MoS2/S-Ti3C2 has the highest electrochemical activity. The as-fabricated MoS2/S-Ti3C2/LGE was used as a novel electrochemical sensing medium for the hazardous aristolochic acid (AA) and roxarsone (ROX) detection. Interestingly, the proposed MoS2/S-Ti3C2/LGE sensor exhibited a high sensitivity of 69.955 and 32.488 mu A mu M-1 cm(-2) for AA and 56.972 and 19.688 mu A mu M-1 cm(-2) for ROX with a detection limit of 1.65 and 2.31 nM, respectively, in the concentration range of 0.01-875.01 mu M. In addition, the influence of few selected potential interferences does not show a significant effect on the sensing of AA and ROX, making it the best sensing device for practicability analysis. Moreover, the practical application of the fabricated sensor was successfully evaluated in asarum sieboldii, human urine, and human blood serum samples with a recovery rate of 97.00-99.00%.
引用
收藏
页码:3252 / 3264
页数:13
相关论文
共 58 条
  • [1] 2D metal carbides and nitrides (MXenes) for energy storage
    Anasori, Babak
    Lukatskaya, Maria R.
    Gogotsi, Yury
    [J]. NATURE REVIEWS MATERIALS, 2017, 2 (02):
  • [2] Rapid Identification and Simultaneous Quantification of Aristolochic Acids by HPLC-DAD and Confirmations by MS in Aristolochia chilensis Using a Limited Biomass
    Araya, Michael
    Garcia, Samantha
    Gonzalez-Teuber, Marcia
    [J]. JOURNAL OF ANALYTICAL METHODS IN CHEMISTRY, 2018, 2018
  • [3] XPS investigation of preferential sputtering of S from MoS2 and determination of MoSx stoichiometry from Mo and S peak positions
    Baker, MA
    Gilmore, R
    Lenardi, C
    Gissler, W
    [J]. APPLIED SURFACE SCIENCE, 1999, 150 (1-4) : 255 - 262
  • [4] Nanohybrids of a MXene and transition metal dichalcogenide for selective detection of volatile organic compounds
    Chen, Winston Yenyu
    Jiang, Xiaofan
    Lai, Sz-Nian
    Peroulis, Dimitrios
    Stanciu, Lia
    [J]. NATURE COMMUNICATIONS, 2020, 11 (01)
  • [5] Speciation of Organoarsenic Species in Food of Animal Origin Using Accelerated Solvent Extraction (ASE) with Determination by HPLC-Hydride Generation-Atomic Fluorescence Spectrometry (HG-AFS)
    Cui, Jian
    Xiao, Ya-bing
    Dai, Li
    Zhao, Xue-hong
    Wang, Yan
    [J]. FOOD ANALYTICAL METHODS, 2013, 6 (02) : 370 - 379
  • [6] Double-amplified photoelectrochemical response of hematin on carbon nanohorns superstructure support for ultrasensitive detection of roxarsone
    Dai, Hong
    Gong, Lingshan
    Xu, Guifang
    Li, Yiling
    Li, Xiuhua
    Zhang, Qingrong
    Lin, Yanyu
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2015, 215 : 45 - 51
  • [7] Layered ternary Mn+1AXn phases and their 2D derivative MXene: an overview from a thin-film perspective
    Eklund, Per
    Rosen, Johanna
    Persson, Per O. A.
    [J]. JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2017, 50 (11)
  • [8] A composite film prepared from titanium carbide Ti3C2Tx (MXene) and gold nanoparticles for voltammetric determination of uric acid and folic acid
    Elumalai, Satheeshkumar
    Mani, Veerappan
    Jeromiyas, Nithiya
    Ponnusamy, Vinoth Kumar
    Yoshimura, Masahiro
    [J]. MICROCHIMICA ACTA, 2020, 187 (01)
  • [9] Determination of dissociation constants of aristolochic acid I and II by capillary electrophoresis with carboxymethyl chitosan-coated capillary
    Fu, Xiaofang
    Liu, Yi
    Li, Wei
    Bai, Yu
    Liao, Yiping
    Liu, Huwei
    [J]. TALANTA, 2011, 85 (01) : 813 - 815
  • [10] A screen-printed electrode modified with tungsten disulfide nanosheets for nanomolar detection of the arsenic drug roxarsone
    Govindasamy, Mani
    Wang, Sea-Fue
    Jothiramalingam, R.
    Ibrahim, S. Noora
    Al-lohedan, Hamad A.
    [J]. MICROCHIMICA ACTA, 2019, 186 (07)