A liquid crystal pixel array for signal discrimination in array biosensors

被引:10
作者
Lundgren, JS [1 ]
Watkins, AN [1 ]
Racz, D [1 ]
Ligler, FS [1 ]
机构
[1] USN, Res Lab, Ctr Biomol Sci & Engn, Washington, DC 20375 USA
关键词
biosensor; liquid crystal array; multi-analyte sensing;
D O I
10.1016/S0956-5663(00)00098-1
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A new optical design uses a liquid crystal pixel array (LCPA) to discriminate multiple fluorescence signals on a two-dimensional biosensor array. The LCPA can selectively control the transmission of fluorescence generated from multiple biosensing elements on a planar waveguide. This device sequentially acquires the fluorescence data from the substrate by making multiple individual measurements of the sensing elements on the waveguide. The biosensing elements are patterned according to the pixel layout of the LCPA and optically aligned so that each electronically driven pixel can either transmit or filter out the fluorescence signal as specified by the user. The primary advantage of this system is that a single detection channel (i.e. photomultiplier tube (PMT)) can be used to measure multiple fluorescence signals from a two-dimensional substrate while the LCPA provides for spatial resolution. We evaluate the performance of the LCPA by testing the optical homogeneity of the liquid crystal pixels and linear dynamic range for transmitting light. The LCPA is also used with well-developed biosensing chemistry modified for this optical format. Published by Elsevier Science S.A.
引用
收藏
页码:417 / 421
页数:5
相关论文
共 14 条
  • [1] Multi-analyte explosive detection using a fiber optic biosensor
    Bakaltcheva, IB
    Ligler, FS
    Patterson, CH
    Shriver-Lake, LC
    [J]. ANALYTICA CHIMICA ACTA, 1999, 399 (1-2) : 13 - 20
  • [2] USE OF THIOL-TERMINAL SILANES AND HETEROBIFUNCTIONAL CROSSLINKERS FOR IMMOBILIZATION OF ANTIBODIES ON SILICA SURFACES
    BHATIA, SK
    SHRIVERLAKE, LC
    PRIOR, KJ
    GEORGER, JH
    CALVERT, JM
    BREDEHORST, R
    LIGLER, FS
    [J]. ANALYTICAL BIOCHEMISTRY, 1989, 178 (02) : 408 - 413
  • [3] EIGLER FS, 1991, Patent No. 5077210
  • [4] FELDSTEIN MJ, 1998, MICRO TOTAL ANAL SYS, P1998
  • [5] HARRISON DJ, 1998, MICRO TOTAL ANAL SYS
  • [6] Surface enhanced Raman gene probe for HIV detection
    Isola, NR
    Stokes, DL
    Vo-Dinh, T
    [J]. ANALYTICAL CHEMISTRY, 1998, 70 (07) : 1352 - 1356
  • [7] Identification of multiple analytes using an optical sensor array and pattern recognition neural networks
    Johnson, SR
    Sutter, JM
    Engelhardt, HL
    Jurs, PC
    White, J
    Kauer, JS
    Dickinson, TA
    Walt, DR
    [J]. ANALYTICAL CHEMISTRY, 1997, 69 (22) : 4641 - 4648
  • [8] Randomly ordered addressable high-density optical sensor arrays
    Michael, KL
    Taylor, LC
    Schultz, SL
    Walt, DR
    [J]. ANALYTICAL CHEMISTRY, 1998, 70 (07) : 1242 - 1248
  • [9] REDFORD GR, 1995, Patent No. 5444235
  • [10] A biosensor array based on polyaniline
    Sangodkar, H
    Sukeerthi, S
    Srinivasa, RS
    Lal, R
    Contractor, AQ
    [J]. ANALYTICAL CHEMISTRY, 1996, 68 (05) : 779 - 783