Glucose concentration can be predicted ahead in time from continuous glucose monitoring sensior time-series

被引:216
作者
Sparacino, Giovanni
Zanderigo, Francesca
Corazza, Stefano
Maran, Alberto
Facchinetti, Andrea
Cobelli, Claudio
机构
[1] Univ Padua, Dept Informat Engn, I-35131 Padua, Italy
[2] Univ Padua, Dept Clin & Expt Med, I-35131 Padua, Italy
关键词
auto-regressive model; diabetes; hypoglycemia; polynomial model;
D O I
10.1109/TBME.2006.889774
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A clinically important task in diabetes management is the prevention of hypo/hyperglycemic events. In this proof-of-concept paper, we assess the feasibility of approaching the problem with continuous glucose monitoring (CGM) devices. In particular, we study the possibility to predict ahead in time glucose levels by exploiting their recent history monitored every 3 min by a minimally invasive CGM system, the Glucoday, in 28 type 1 diabetic volunteers for 48 h. Simple prediction strategies, based on the description of past glucose data by either a first-order polynomial or a first-order autoregressive (AR) model, both with time-varying parameters determined by weighted least squares, are considered. Results demonstrate that, even by using these simple methods, glucose can be predicted ahead in time, e.g., with a prediction horizon of 30 min crossing of the hypoglycemic threshold can be predicted 20-25 min ahead in time, a sufficient margin to mitigate the event by sugar ingestion.
引用
收藏
页码:931 / 937
页数:7
相关论文
共 8 条
[1]  
Bode Bruce, 2004, Diabetes Technol Ther, V6, P105, DOI 10.1089/152091504773731285
[2]   Is blood glucose predictable from previous values? A solicitation for data [J].
Bremer, T ;
Gough, DA .
DIABETES, 1999, 48 (03) :445-451
[3]   Prevention of hypoglycemia using risk assessment with a continuous glucose monitoring system [J].
Choleau, C ;
Dokladal, P ;
Klein, JC ;
Ward, WK ;
Wilson, GS ;
Reach, G .
DIABETES, 2002, 51 (11) :3263-3273
[4]  
FELDMAN B, 2004, P 40 EASD ANN M WORK
[5]   Continuous glucose monitoring - Roadmap for 21st century diabetes therapy [J].
Klonoff, DC .
DIABETES CARE, 2005, 28 (05) :1231-1239
[6]  
Ljung L, 1999, SYSTEM IDENTIFICATIO
[7]   Continuous subcutaneous glucose monitoring in diabetic patients - A multicenter analysis [J].
Maran, A ;
Crepaldi, C ;
Tiengo, A ;
Grassi, G ;
Vitali, E ;
Pagano, G ;
Bistoni, S ;
Calabrese, G ;
Santeusanio, F ;
Leonetti, F ;
Ribaudo, M ;
Di Mario, U ;
Annuzzi, G ;
Genovese, S ;
Riccardi, G ;
Previti, M ;
Cucinotta, D ;
Giorgino, F ;
Bellomo, A ;
Giorgino, R ;
Poscia, A ;
Varalli, M .
DIABETES CARE, 2002, 25 (02) :347-352
[8]  
Niedzwiecki M., 2000, IDENTIFICATION TIME