Array compression for MRI with large coil arrays

被引:199
作者
Buehrer, Martin
Pruessmann, Klaas P.
Boesiger, Peter
Kozerke, Sebastian
机构
[1] Univ Zurich, Inst Biomed Engn, CH-8092 Zurich, Switzerland
[2] Swiss Fed Inst Technol, CH-8092 Zurich, Switzerland
关键词
coil array; data compression; parallel imaging; SENSE; k-space;
D O I
10.1002/mrm.21237
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Arrays with large numbers of independent coil elements are becoming increasingly available as they provide increased signal-to-noise ratios (SNRs) and improved parallel imaging performance. Processing of data from a large set of independent receive channels is, however, associated with an increased memory and computational load in reconstruction. This work addresses this problem by introducing coil array compression. The method allows one to reduce the number of datasets from independent channels by combining all or partial sets in the time domain prior to image reconstruction. It is demonstrated that array compression can be very effective depending on the size of the region of interest (ROI). Based on 2D in vivo data obtained with a 32-element phased-array coil in the heart, it is shown that the number of channels can be compressed to as few as four with only 0.3% SNR loss in an ROI encompassing the heart. With twofold parallel imaging, only a 2% loss in SNR occurred using the same compression factor.
引用
收藏
页码:1131 / 1139
页数:9
相关论文
共 18 条
[1]   Coil setup optimization for 2D-SENSE whole-heart coronary imaging [J].
Buehrer, M ;
Huber, ME ;
Wiesinger, F ;
Boesiger, P ;
Kozerke, S .
MAGNETIC RESONANCE IN MEDICINE, 2006, 55 (02) :460-464
[2]   Generalized Autocalibrating Partially Parallel Acquisitions (GRAPPA) [J].
Griswold, MA ;
Jakob, PM ;
Heidemann, RM ;
Nittka, M ;
Jellus, V ;
Wang, JM ;
Kiefer, B ;
Haase, A .
MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (06) :1202-1210
[3]   Eigenmode analysis for understanding phased array coils and their limits [J].
King, SB ;
Varosi, SM ;
Duensing, GR .
CONCEPTS IN MAGNETIC RESONANCE PART B-MAGNETIC RESONANCE ENGINEERING, 2006, 29B (01) :42-49
[4]  
KING SB, 2003, P 11 ANN M ISMRM TOR
[5]   64-channel array coil for single echo acquisition magnetic resonance imaging [J].
McDougall, MP ;
Wright, SM .
MAGNETIC RESONANCE IN MEDICINE, 2005, 54 (02) :386-392
[6]   Ultimate intrinsic signal-to-noise ratio for parallel MRI: Electromagnetic field considerations [J].
Ohliger, MA ;
Grant, AK ;
Sodickson, DK .
MAGNETIC RESONANCE IN MEDICINE, 2003, 50 (05) :1018-1030
[7]   An introduction to coil array design for parallel MRI [J].
Ohliger, Michael A. ;
Sodickson, Daniel K. .
NMR IN BIOMEDICINE, 2006, 19 (03) :300-315
[8]   A 16-element phased-array head coil [J].
Porter, JR ;
Wright, SM ;
Reykowski, A .
MAGNETIC RESONANCE IN MEDICINE, 1998, 40 (02) :272-279
[9]  
Pruessmann KP, 1999, MAGNET RESON MED, V42, P952, DOI 10.1002/(SICI)1522-2594(199911)42:5<952::AID-MRM16>3.0.CO
[10]  
2-S