OBJECTIVE. The purpose of our study was to quantify the effect of changes made to the CT chest protocol on patient dose, image quality, and image noise when using a kilovoltage (kVp)-lowering strategy. MATERIALS AND METHODS. We retrospectively selected 120 children who underwent chest CT: 60 in 2006 and 60 in 2008. In each group there were 30 children weighing less than 15 kg and 30 between 15 and 60 kg. In 2006 the CT protocol was 120 kVp and the reference current (mAs) was 65. In 2008, the kVp was 80 for < 15 kg and 100 for 15-60 kg, with reference mAs of 55. For each examination, the volume CT dose index (CTDIvol) and dose-length product (DLP) were recorded. Effective dose (ED) was estimated using the DLP method. Image noise was measured. Overall image quality was subjectively evaluated. RESULTS. For a weight < 15.0 kg, the CTDIvol, DLP, and ED were reduced by 73%, 75%, and 73%, respectively (p < 0.05). For the weight range 15-60 kg, the CTDIvol, DLP, and ED were reduced by 45%, 44%, and 48%, respectively (p < 0.05). Measured noise increased by 55% in the younger children and 41% in the older group (p < 0.05). All studies were considered diagnostically adequate. CONCLUSION. Significant radiation dose reduction can be achieved for routine pediatric chest CT by weight-based decreases in kVp in addition to low mAs. Increased noise was considered an acceptable trade-off for decreased dose, and image quality was acceptable.
引用
收藏
页码:1188 / 1193
页数:6
相关论文
共 23 条
  • [1] Pediatric body MDCT: A 5-year follow-up survey of scanning parameters used by pediatric radiologists
    Arch, Michael E.
    Frush, Donald P.
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2008, 191 (02) : 611 - 617
  • [2] Estimated risks of radiation-induced fatal cancer from pediatric CT
    Brenner, DJ
    Elliston, CD
    Hall, EJ
    Berdon, WE
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2001, 176 (02) : 289 - 296
  • [3] Scanning beyond anatomic limits of the thorax in chest CT: Findings, radiation dose, and automatic tube current modulation
    Campbell, J
    Kalra, MK
    Rizzo, S
    Maher, MM
    Shepard, JA
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2005, 185 (06) : 1525 - 1530
  • [4] COURSEY C, 2008, AJR, V190, P244
  • [5] Low-dose ECG-gated 64-slices helical CT angiography of the chest: evaluation of image quality in 105 patients
    d'Agostino, A. G.
    Remy-Jardin, M.
    Khalil, C.
    Delannoy-Deken, V.
    Flohr, T.
    Duhamel, A.
    Remy, J.
    [J]. EUROPEAN RADIOLOGY, 2006, 16 (10) : 2137 - 2146
  • [6] Individually adapted examination protocols for reduction of radiation exposure for 16-MDCT chest examinations
    Das, M
    Mahnken, AH
    Mühlenbruch, G
    Stargardt, A
    Weiss, C
    Sennst, DA
    Flohr, TG
    Günther, RW
    Wildberger, JE
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2005, 184 (05) : 1437 - 1443
  • [7] Computer-simulated radiation dose reduction for abdominal multidetector CT of pediatric patients
    Frush, DP
    Slack, CC
    Hollingsworth, CL
    Bisset, GS
    Donnelly, LF
    Hsieh, J
    Lavin-Wensell, T
    Mayo, JR
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2002, 179 (05) : 1107 - 1113
  • [8] Tube current reduction in pediatric non-ECG-gated heart CT by combined tube current modulation
    Goo, HW
    Suh, DS
    [J]. PEDIATRIC RADIOLOGY, 2006, 36 (04) : 344 - 351
  • [9] Dose reduction in subsecond multislice spiral CT examination of children by online tube current modulation
    Greess, H
    Lutze, J
    Nömayr, A
    Wolf, H
    Hothorn, T
    Kalender, WA
    Bautz, W
    [J]. EUROPEAN RADIOLOGY, 2004, 14 (06) : 995 - 999
  • [10] Dose reduction in computed tomography by attenuation-based on-line modulation of tube current: evaluation of six anatomical regions
    Greess, H
    Wolf, H
    Baum, U
    Lell, M
    Pirkl, M
    Kalender, W
    Bautz, WA
    [J]. EUROPEAN RADIOLOGY, 2000, 10 (02) : 391 - 394