Reproducible coronary plaque quantification by multislice computed tomography

被引:21
作者
Bruining, Nico
Roelandt, Jos R. T. C.
Palumbo, Alessandro
La Grutta, Ludovico
Cademartiri, Filippo
de Feijter, Pirn J.
Mollet, Nico
van Domburg, Ron T.
Serruys, P. W.
Hamers, Ronald
机构
[1] Erasmus MC, Thoraxctr, Dept Cardiol, NL-3000 DR Rotterdam, Netherlands
[2] Erasmus MC, Thoraxctr, Dept Radiol, NL-3000 DR Rotterdam, Netherlands
关键词
multislice computed tomography; intravascular ultrasound; image processing; coronary artery disease;
D O I
10.1002/ccd.21067
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: The aim of this study was to investigate reproducibility and accuracy of computer-assisted coronary plaque measurements by multislice computed tomography coronary angiography (QMSCT-CA). Methods and Results: Forty-eight patients undergoing MSCT-CA and coronary arteriography for symptomatic coronary artery disease and quantitative intravascular ultrasound (IVUS, QCU) were examined. Two investigators performed the QMSCT-CA twice and a third investigator performed the QCU, all blinded for each other's results. There was no difference found for the matched region of interest (ROI) lengths (OCU 29.4 +/- 13 mm vs. QMSCT-CA 29.6 +/- 13 mm, P = 0.6; total length = 1,400 mm). The comparison of volumetric measurements showed (lumen QCU 267 +/- 139 mm 3 vs. mean QMSCT-CA 177 +/- 91 mm(3), P < 0.001; vessel 454 < 194 mm(3) vs. 398 +/- 187 mm 3, P < 0.001; and plaque 189 +/- 93 mm(3) vs. 222 +/- 121 mm(3); investigator 1, P = 0.02; and investigator 2, P = 0.07) significant differences. Automated lumen detection was also applied for QMSCT-CA (218 +/- 112 mm(3), p < 0.001 vs. QCU). The interinvestigator variability measurements for QMSCT-CA showed no significant differences. Conclusion: QMSCT-CA systematically underestimates absolute coronary lumen- and vessel dimensions when compared with OCU. However, repeated measurements of coronary plaque by QMSCT-CA showed no statistically significant differences, although, the outcome showed a scattered result. Automated lumen detection for QMSCT-CA showed improved results when compared with those of human investigators. (c) 2007Wiley-Liss, Inc.
引用
收藏
页码:857 / 865
页数:9
相关论文
共 29 条
  • [1] Detection of calcified and noncalcified coronary atherosclerotic plaque by contrast-enhanced, submillimeter multidetector spiral computed tomography - A segment-based comparison with intravascular ultrasound
    Achenbach, S
    Moselewski, F
    Ropers, D
    Ferencik, M
    Hoffmann, U
    MacNeill, B
    Pohle, K
    Baum, U
    Anders, K
    Jang, I
    Daniel, WG
    Brady, TJ
    [J]. CIRCULATION, 2004, 109 (01) : 14 - 17
  • [2] STATISTICS NOTES .1. CORRELATION, REGRESSION, AND REPEATED DATA
    BLAND, JM
    ALTMAN, DG
    [J]. BRITISH MEDICAL JOURNAL, 1994, 308 (6933) : 896 - 896
  • [3] Bruining N, 1998, CATHETER CARDIO DIAG, V43, P254, DOI 10.1002/(SICI)1097-0304(199803)43:3<254::AID-CCD3>3.0.CO
  • [4] 2-8
  • [5] Adjustment method for mechanical Boston scientific corporation 30 MHz intravascular ultrasound catheters connected to a Clearview® console -: Mechanical 30 MHz IVUS Catheter Adjustment
    Bruining, N
    Hamers, R
    Teo, TJ
    de Feijter, PJ
    Serruys, PW
    Roelandt, JRTC
    [J]. INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2004, 20 (02) : 83 - 91
  • [6] Characterization of vulnerable nonstenotic plaque with 16-slice computed tomography compared with intravascular sound
    Caussin, C
    Ohanessian, A
    Ghostine, S
    Jacq, L
    Lancelin, B
    Dambrin, G
    Sigal-Cinqualbre, A
    Angel, CY
    Paul, JF
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2004, 94 (01) : 99 - 104
  • [7] Retrospective image-based gating of intracoronary ultrasound images for improved quantitative analysis: The intelligate method
    de Winter, SA
    Hamers, R
    Degertekin, M
    Tanabe, K
    Lemos, PA
    Serruys, PW
    Roelandt, JRTC
    Bruining, N
    [J]. CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2004, 61 (01) : 84 - 94
  • [8] A novel approach to quantitative analysis of intra vascular ultrasound images
    Hamers, R
    Bruining, N
    Knook, M
    Sabate, M
    Roelandt, JRTC
    [J]. COMPUTERS IN CARDIOLOGY 2001, VOL 28, 2001, 28 : 589 - 592
  • [9] Hodgson J M, 1990, Echocardiography, V7, P403, DOI 10.1111/j.1540-8175.1990.tb00381.x
  • [10] Multislice helical CT of the heart with retrospective ECG gating: reduction of radiation exposure by ECG-controlled tube current modulation
    Jakobs, TF
    Becker, CR
    Ohnesorge, B
    Flohr, T
    Suess, C
    Schoepf, UJ
    Reiser, MF
    [J]. EUROPEAN RADIOLOGY, 2002, 12 (05) : 1081 - 1086