Crosstalk in Elliptical Sensor Arrays for Current Measurement

被引:8
|
作者
Zapf, Florian [1 ]
Weiss, Roland [1 ]
Weigel, Robert [2 ]
机构
[1] Siemens AG, Sensor Syst Integrat, Technol, D-91058 Erlangen, Germany
[2] Friedrich Alexander Univ Erlangen Nurnberg, Inst Elect Engn LTE, D-91058 Erlangen, Germany
关键词
Sensor arrays; Conductors; Current measurement; Crosstalk; Calibration; Magnetic fields; Magnetic cores; Ampere's circuital law; bus bar; circular sensor array; contactless current measurement; crosstalk error; elliptical sensor array; Hall effect sensors; interference current; magnetic field sensors (MFS); MAGNETIC SENSORS; CIRCULAR ARRAYS; INTERFERENCE;
D O I
10.1109/TIM.2022.3162625
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Contactless current sensors that use arrays of magnetic field sensors are a good alternative to core-based current sensors because the omission of the magnetic core offers many advantages. Particularly, circular sensor arrays have proven to feature good robustness against various error sources. As rectangular bus bars are frequently used for local high-current power distribution systems, elliptic arrays would require less space than circular arrays. Up until now, no publication on magnetic interference errors of elliptic sensor arrays has been presented. This article examines the crosstalk error for different sensor distribution methods, aspect ratios, numbers of sensors, and offset angles with calculations and measurements. Therefore, an interference conductor is positioned at different angles and distances relative to the elliptic arrays. We show that the crosstalk error can be reduced with our elliptic designs in comparison to a circular design with an equal number of sensors and an equal length of the semimajor axis. The projection distribution typically offers a five times smaller crosstalk error compared to the uniform curve segment length distribution. To support the design of elliptical arrays, instructions for the optimization against interference errors for elliptic sensor arrays are given in this article. Thus, an optimal offset angle for the reduction of the crosstalk error is presented.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] An Optimization Approach to Eliminate Crosstalk in Zero-Potential Circuits for Reading Resistive Sensor Arrays
    Dominguez-Gimeno, Sergio
    Medrano-Sanchez, Carlos
    Igual-Catalan, Raul
    Martinez-Cesteros, Javier
    Plaza-Garcia, Inmaculada
    IEEE SENSORS JOURNAL, 2023, 23 (13) : 14215 - 14225
  • [32] Influence of the Conductor Position on a Circular Array of Hall Sensors for Current Measurement
    Itzke, Alexander
    Weiss, Roland
    Weigel, Robert
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2019, 66 (01) : 580 - 585
  • [33] A Projection Transformation Method for Eliminating Crosstalk in Networked Thermopile Arrays
    Feng, Wanjin
    Fu, Jianyu
    Hou, Ying
    Liu, Chao
    Huang, Peng
    Chen, Dapeng
    IEEE SENSORS JOURNAL, 2022, 22 (04) : 3263 - 3269
  • [34] Development of a Zero-Flux Hall Current Sensor Dedicated for Large-Current Measurement of Superconducting Cable
    Liu, Peng
    Wang, Wei
    Zhou, Li
    Zhao, Mengchao
    Wu, Chenghuai
    He, Lin
    Liu, Haoyan
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2025, 35 (05)
  • [35] C-Shape Busbar With Frequency Invariant Points for Wideband Current Measurement
    George, Noby
    Ripka, Pavel
    Grim, Vaclav
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2024, 71 (06) : 6446 - 6456
  • [36] Design and Optimization of Magnetic Shielding Structures for Current Measurement in Triangularly Arranged Conductors
    Zhou, Xingyu
    Cai, Dongsheng
    Zhang, Zhengyuan
    Han, Zhiwei
    Wang, Peng
    Khawaja, Arsalan Habib
    Huang, Qi
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2024, 60 (05) : 7746 - 7756
  • [37] Tunnel Magnetoresistive Sensor Design and Applications for Current Measurement
    Li Qiuyang
    Chen Siyu
    Xiong Suqin
    Zhang Penghe
    ELEVENTH INTERNATIONAL CONFERENCE ON SIGNAL PROCESSING SYSTEMS, 2019, 11384
  • [38] Interference-rejecting current measurement method with tunnel magnetoresistive magnetic sensor array
    Chen, Yafeng
    Huang, Qi
    Khawaja, Arsalan Habib
    IET SCIENCE MEASUREMENT & TECHNOLOGY, 2018, 12 (06) : 733 - 738
  • [39] A Self-Healing Magnetic-Array-Type Current Sensor With Data-Driven Identification of Abnormal Magnetic Measurement Units
    Liu, Xiaohu
    Ma, Kang
    Liu, Jian
    Zhao, Wei
    Peng, Lisha
    Huang, Songling
    Li, Shisong
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2024, 73
  • [40] Uncertainty Analysis in the Inverse of Equivalent Conductance Method for Dealing With Crosstalk in 2-D Resistive Sensor Arrays
    Martinez-Cesteros, Javier
    Medrano-Sanchez, Carlos
    Plaza-Garcia, Inmaculada
    Igual-Catalan, Raul
    IEEE SENSORS JOURNAL, 2022, 22 (01) : 373 - 384