摘要
Background. Atherosclerotic plaque burden is the major end point in ongoing progression trials. Intravascular ultrasound allows precise measurements of coronary artery dimensions. However, the variability of measurements among different catheter systems is incompletely characterized. Methods: Intravascular ultrasound imaging was performed in a cylindric phantom with 5 sections of different, known, cross-sectional area ranging from 3.24 to 27.99 mm(2). A total of 3637 measurements with different catheter systems (Atlantis SR and Ultracross, Scimed/Boston Scientific; and Invision and Avanar, joined) were performed. Measurements were divided into model building and validation datasets. For each catheter, calibration models were developed. Results: Overestimation and underestimation of the true cross-sectional area of up to 18% was observed with different catheter systems. Calibration equations for the different systems could be developed that predicted the true diameter and area with high statistical precision (adjusted R-2>0.99). Conclusions. Area measurements vary among different intravascular ultrasound catheter systems. Calibration equations can correct for these differences and allow the comparison of measurements among catheters.
引用
收藏
页码:277 / 284
页数:8
相关论文
共 14 条
  • [1] ANDERSON MH, 1992, BRIT HEART J, P276
  • [2] INVITRO AND INVIVO INTRAVASCULAR ULTRASOUND IMAGING
    BARTORELLI, AL
    NEVILLE, RF
    KEREN, G
    POTKIN, BN
    ALMAGOR, Y
    BONNER, RF
    GESSERT, JM
    LEON, MB
    [J]. EUROPEAN HEART JOURNAL, 1992, 13 (01) : 102 - 108
  • [3] GE J, 1991, Z KARDIOL, V80, P595
  • [4] Suitability of the Cordis Stabilizer™ marker guide wire for quantitative coronary angiography calibration:: An in vitro and in vivo study
    Koning, G
    Hekking, E
    Kemppainen, JS
    Richardson, GA
    Rothman, MT
    Reiber, JHC
    [J]. CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2001, 52 (03) : 334 - 341
  • [5] American College of Cardiology Clinical Expert Consensus Document on Standards for Acquisition, Measurement and Reporting of Intravascular Ultrasound Studies (IVUS) - A report of the American College of Cardiology Task Force on Clinical Expert Consensus - Documents developed in collaboration with the European Society of Cardiology endorsed by the Society of Cardiac Angiography and Interventions
    Mintz, GS
    Nissen, SE
    Anderson, WD
    Bailey, SR
    Erbel, R
    Fitzgerald, PJ
    Pinto, FJ
    Rosenfield, K
    Siegel, RJ
    Tuzcu, EM
    Yock, PG
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2001, 37 (05) : 1478 - 1492
  • [6] INTRAVASCULAR ULTRASOUND IMAGING - INVITRO VALIDATION AND PATHOLOGICAL CORRELATION
    NISHIMURA, RA
    EDWARDS, WD
    WARNES, CA
    REEDER, GS
    HOLMES, DR
    TAJIK, AJ
    YOCK, PG
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1990, 16 (01) : 145 - 154
  • [7] INTRAVASCULAR ULTRASOUND ASSESSMENT OF LUMEN SIZE AND WALL MORPHOLOGY IN NORMAL SUBJECTS AND PATIENTS WITH CORONARY-ARTERY DISEASE
    NISSEN, SE
    GURLEY, JC
    GRINES, CL
    BOOTH, DC
    MCCLURE, R
    BERK, M
    FISCHER, C
    DEMARIA, AN
    [J]. CIRCULATION, 1991, 84 (03) : 1087 - 1099
  • [8] NISSEN SE, 2000, AM J CARDIOL, V86
  • [9] CORONARY-ARTERY IMAGING WITH INTRAVASCULAR HIGH-FREQUENCY ULTRASOUND
    POTKIN, BN
    BARTORELLI, AL
    GESSERT, JM
    NEVILLE, RF
    ALMAGOR, Y
    ROBERTS, WC
    LEON, MB
    [J]. CIRCULATION, 1990, 81 (05) : 1575 - 1585
  • [10] REIBER JHC, 1985, CATHETER CARDIO DIAG, V11, P512