摘要
This paper introduces an automatic non-contact monitoring method based on the synchronous evaluation of a 3D time-of-flight (ToF) camera and a microwave interferometric radar sensor for measuring the respiratory rate of neonates. The current monitoring on the Neonatal Intensive Care Unit (NICU) has several issues which can cause pressure marks, skin irritations and eczema. To minimize these risks, a non-contact system made up of a 3D time-of-flight camera and a microwave interferometric radar sensor is presented. The 3D time-of-flight camera delivers 3D point clouds which can be used to calculate the change in distance of the moving chest and from it the respiratory rate. The disadvantage of the ToF camera is that the heartbeat cannot be determined. The microwave interferometric radar sensor determines the change in displacement caused by the respiration and is even capable of measuring the small superimposed movements due to the heartbeat. The radar sensor is very sensitive towards movement artifacts due to, e.g., the baby moving its arms. To allow a robust vital parameter detection the data of both sensors was evaluated synchronously. In this publication, we focus on the first step: determining the respiratory rate. After all processing steps, the respiratory rate determined by the radar sensor was compared to the value received from the 3D time-of-flight camera. The method was validated against our gold standard: a self-developed neonatal simulation system which can simulate different breathing patterns. In this paper, we show that we are the first to determine the respiratory rate by evaluating the data of an interferometric microwave radar sensor and a ToF camera synchronously. Our system delivers very precise breaths per minute (BPM) values within the norm range of 20-60 BPM with a maximum difference of 3 BPM (for the ToF camera itself at 30 BPM in normal mode). Especially in lower respiratory rate regions, i.e., 5 and 10 BPM, the synchronous evaluation is required to compensate the drawbacks of the ToF camera. In the norm range, the ToF camera performs slightly better than the radar sensor.
引用
收藏
页数:26
相关论文
共 31 条
  • [21] A Dynamically Consistent Hierarchical Control Architecture for Robotic-Assisted Tele-Echography with Motion and Contact Dynamics driven by a 3D Time-of-Flight Camera and a Force Sensor
    Santos, Luis
    Cortesao, Rui
    2015 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND AUTOMATION (ICRA), 2015, : 2931 - 2937
  • [22] MPEG-4-Based 3D Video Contents Creation Method using Time-of-Flight Sensor for 3DTV
    Cho, Ji-Ho
    Kim, Sung-Yeol
    Lee, Kwan H.
    PROCEEDINGS ELMAR-2010, 2010, : 459 - 462
  • [23] Low-power, 20 meter 3D ranging SPAD camera based on continuous-wave indirect Time-of-Flight
    Bellisai, S.
    Ferretti, L.
    Villa, F.
    Ruggeri, A.
    Tisa, S.
    Tosi, A.
    Zappa, F.
    ADVANCED PHOTON COUNTING TECHNIQUES VI, 2012, 8375
  • [24] MSCAN: AN AUTOMATED IN-SITU FAULT DETECTION SYSTEM FOR DESKTOP FUSED FILAMENT FABRICATION 3D PRINTERS UTILIZING A NON-CONTACT SENSOR
    Lyu, Hanyao
    Wu, Pinyi
    Okwudire, Chinedum
    PROCEEDINGS OF ASME 2024 19TH INTERNATIONAL MANUFACTURING SCIENCE AND ENGINEERING CONFERENCE, MSEC2024, VOL 1, 2024,
  • [25] Evaluation of a 3D imaging vision system based on a single-pixel InGaAs detector and the Time-of-Flight principle for drones
    Osorio Quero, C.
    Durini, D.
    Ramos-Garcia, R.
    Rangel-Magdaleno, J.
    Martinez-Carranza, J.
    THREE-DIMENSIONAL IMAGING, VISUALIZATION, AND DISPLAY 2020, 2020, 11402
  • [26] A Non-contact approach for cable tension evaluation based on 3D laser scanning data and nonlinear finite element analysis
    Srimontriphakdi, Thaniyaphat
    Mahasuwanchai, Peerasit
    Athisakul, Chainarong
    Leelataviwat, Sutat
    Klaycham, Karun
    Poovarodom, Nakhorn
    Magteppong, Nuttaphon
    Chucheepsakul, Somchai
    MEASUREMENT, 2023, 212
  • [27] Pavement Skid Resistance Evaluation Based on Hyperopt-NGBoost Fusion Model Using Non-contact Measurement of 3D Macrotexture Data
    Hu, Yuanjiao
    Sun, Zhaoyun
    Han, Yuxi
    Hao, Xueli
    Pei, Lili
    ARABIAN JOURNAL FOR SCIENCE AND ENGINEERING, 2023, 48 (04) : 5507 - 5524
  • [28] Pavement Skid Resistance Evaluation Based on Hyperopt-NGBoost Fusion Model Using Non-contact Measurement of 3D Macrotexture Data
    Yuanjiao Hu
    Zhaoyun Sun
    Yuxi Han
    Xueli Hao
    Lili Pei
    Arabian Journal for Science and Engineering, 2023, 48 : 5507 - 5524
  • [29] Clinical evaluation of subtracted pointwise encoding time reduction with radial acquisition-based magnetic resonance angiography compared to 3D time-of-flight magnetic resonance angiography for improved flow dephasing at 3 Tesla
    Fu, Qing
    Zhang, Xiao-yong
    Deng, Xian-bo
    Liu, Ding-xi
    MAGNETIC RESONANCE IMAGING, 2020, 73 : 104 - 110
  • [30] Long-term predictive factors of the morphology based outcome in bare platinum coiled intracranial aneurysms: Evaluation by pre- and post-contrast 3D time-of-flight MR angiography
    Ueda, Fumiaki
    Uchiyama, Naoyuki
    Mohri, Masanao
    Misaki, Kouichi
    Matsui, Osamu
    Kida, Shinya
    Sanada, Junichiro
    Yoshikawa, Jun
    Aburano, Hiroyuki
    Yoshie, Yuichi
    Gabata, Toshifumi
    NEUROLOGIA I NEUROCHIRURGIA POLSKA, 2017, 51 (02) : 116 - 126