A comparison of laser ablation-inductively coupled plasma-mass spectrometry and high-resolution continuum source graphite furnace molecular absorption spectrometry for the direct determination of bromine in polymers

被引:14
|
作者
de Gois, Jefferson S. [1 ,2 ,3 ]
Van Malderen, Stijn J. M. [2 ]
Cadorim, Heloisa R. [1 ]
Welz, Bernhard [1 ,4 ]
Vanhaecke, Frank [2 ]
机构
[1] Univ Fed Santa Catarina, Dept Chem, Florianopolis, SC, Brazil
[2] Univ Ghent, Dept Analyt Chem, Ghent, Belgium
[3] Univ Estado Rio De Janeiro, Dept Analyt Chem, Rio De Janeiro, Brazil
[4] Univ Fed Bahia, Inst Nacl Ciencia & Tecnol, INCT Energia & Ambiente, CNPq, Salvador, BA, Brazil
关键词
Bromine; Polymer; Halogen; LA-ICP-MS; HR-CS GF MAS; LA-ICP-MS; SOLID SAMPLE ANALYSIS; FLAME RETARDANTS; DIGESTION; HALOGENS; CHLORINE; SULFUR; CARBON; SIZE;
D O I
10.1016/j.sab.2017.04.003
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
This work describes the development and comparison.of two methods for the direct determination of Br in polymer samples via solid sampling, one using laser ablation-inductively coupled plasma-mass spectrometry (LA-ICP-MS) and the other using high-resolution continuum source graphite furnace molecular absorption spectrometry with direct solid sample analysis (HR-CS SS-GF MAS). The methods were optimized and their accuracy was evaluated by comparing the results obtained for 6 polymeric certified reference materials (CRMs) with the corresponding certified values. For Br determination with LA-ICP-MS, the 79Br signal could be monitored interference-free. For Br determination via HR-CS SS-GF MAS, the CaBr molecule was monitored at 625315 nm with integration of the central pixel +/- 1. Bromine quantification by LA-ICP-MS was performed via external calibration against a single CRM while using the C-12(+) signal as an internal standard. With HR-CS SS-GF MAS, Br quantification could be accomplished using external calibration against aqueous standard solutions. Except for one LA-IC-PMS result, the concentrations obtained with both techniques were in agreement with the certified values within the experimental uncertainty as evidenced using a t-test (95% confidence level). The limit of quantification was determined to be 100 jig g(-1) Br for LA-ICP-MS and 100 mu g(-1) Br for HR-CS SS-GF MAS. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:50 / 55
页数:6
相关论文
共 50 条
  • [41] METTALOTHIONEIN SENSING USING MOLECULARLY IMPRINTED POLYMERS COUPLED LASER ABLATION INDUCTIVELY COUPLED PLASMA-MASS SPECTROMETRY
    Zemankova, Kristyna
    Pavelicova, Kristyna
    Bezdekova, Jaroslava
    Nejdl, Lukas
    Vejvodova, Marketa
    Vaculovic, Tomas
    Vaculovicova, Marketa
    12TH INTERNATIONAL CONFERENCE ON NANOMATERIALS - RESEARCH & APPLICATION (NANOCON 2020), 2021, : 385 - 389
  • [42] Determination of sulfur in crude oil using high-resolution continuum source molecular absorption spectrometry of the SnS molecule in a graphite furnace
    Cadorim, Heloisa R.
    Pereira, Ederson R.
    Carasek, Eduardo
    Welz, Bernhard
    de Andrade, Jails On B.
    TALANTA, 2016, 146 : 203 - 208
  • [43] Chlorine isotope determination via the monitoring of the AlCl molecule by high-resolution continuum source graphite furnace molecular absorption spectrometry - a case study
    Nakadi, F. V.
    da Veiga, M. A. M. S.
    Aramendia, M.
    Garcia-Ruiz, E.
    Resano, M.
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2015, 30 (07) : 1531 - 1540
  • [44] Determination of phospholipids in soybean lecithin samples via the phosphorus monoxide molecule by high-resolution continuum source graphite furnace molecular absorption spectrometry
    Pires, Lais N.
    Brandao, Geovani C.
    Teixeira, Leonardo S. G.
    FOOD CHEMISTRY, 2017, 225 : 162 - 166
  • [45] Understanding polyatomic interference in the determination of phosphorusviaPO molecules using high-resolution continuum source graphite furnace molecular absorption spectrometry with direct solid analysis
    Pomarolli, Luiza Carolina
    Mesquita Silva da Veiga, Marcia Andreia
    Resano, Martin
    Venancio Nakadi, Flavio
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2020, 35 (10) : 2305 - 2314
  • [46] Method development for the determination of bromine via molecular absorption of barium monobromide by high-resolution continuum source molecular absorption spectrometry
    Turhan, Neslihan
    Ozbek, Nil
    Akman, Suleyman
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2019, 34 (03) : 577 - 582
  • [47] Determination of major and trace elements in silicate rock fused with lithium metaborate using laser ablation-inductively coupled plasma-mass spectrometry
    Qiu, Xiaoyun
    Hu, Zhaochu
    He, Tao
    Luo, Tao
    Zhang, Wen
    Li, Ming
    Zong, Keqing
    Wang, Zaicong
    Liu, Yongsheng
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2024, 39 (02) : 545 - 557
  • [48] Application of Laser Ablation-Inductively Coupled Plasma-Mass Spectrometry to studies of chemical diffusion, sorption, and transport in natural rock
    Hu, Qinhong
    Mao, Xianglei
    GEOCHEMICAL JOURNAL, 2012, 46 (05) : 459 - 475
  • [49] Elemental bio-imaging of trace elements in teeth using laser ablation-inductively coupled plasma-mass spectrometry
    Hare, Dominic
    Austin, Christine
    Doble, Philip
    Arora, Manish
    JOURNAL OF DENTISTRY, 2011, 39 (05) : 397 - 403
  • [50] Visualising mouse neuroanatomy and function by metal distribution using laser ablation-inductively coupled plasma-mass spectrometry imaging
    Paul, Bence
    Hare, Dominic J.
    Bishop, David P.
    Paton, Chad
    Van Tran Nguyen
    Cole, Nerida
    Niedwiecki, Megan M.
    Andreozzi, Erica
    Vais, Angela
    Billings, Jessica L.
    Bray, Lisa
    Bush, Ashley I.
    McColl, Gawain
    Roberts, Blaine R.
    Adlard, Paul A.
    Finkelstein, David I.
    Hellstrom, John
    Hergt, Janet M.
    Woodhead, Jon D.
    Doble, Philip A.
    CHEMICAL SCIENCE, 2015, 6 (10) : 5383 - 5393