A comparison of laser ablation-inductively coupled plasma-mass spectrometry and high-resolution continuum source graphite furnace molecular absorption spectrometry for the direct determination of bromine in polymers

被引:14
|
作者
de Gois, Jefferson S. [1 ,2 ,3 ]
Van Malderen, Stijn J. M. [2 ]
Cadorim, Heloisa R. [1 ]
Welz, Bernhard [1 ,4 ]
Vanhaecke, Frank [2 ]
机构
[1] Univ Fed Santa Catarina, Dept Chem, Florianopolis, SC, Brazil
[2] Univ Ghent, Dept Analyt Chem, Ghent, Belgium
[3] Univ Estado Rio De Janeiro, Dept Analyt Chem, Rio De Janeiro, Brazil
[4] Univ Fed Bahia, Inst Nacl Ciencia & Tecnol, INCT Energia & Ambiente, CNPq, Salvador, BA, Brazil
关键词
Bromine; Polymer; Halogen; LA-ICP-MS; HR-CS GF MAS; LA-ICP-MS; SOLID SAMPLE ANALYSIS; FLAME RETARDANTS; DIGESTION; HALOGENS; CHLORINE; SULFUR; CARBON; SIZE;
D O I
10.1016/j.sab.2017.04.003
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
This work describes the development and comparison.of two methods for the direct determination of Br in polymer samples via solid sampling, one using laser ablation-inductively coupled plasma-mass spectrometry (LA-ICP-MS) and the other using high-resolution continuum source graphite furnace molecular absorption spectrometry with direct solid sample analysis (HR-CS SS-GF MAS). The methods were optimized and their accuracy was evaluated by comparing the results obtained for 6 polymeric certified reference materials (CRMs) with the corresponding certified values. For Br determination with LA-ICP-MS, the 79Br signal could be monitored interference-free. For Br determination via HR-CS SS-GF MAS, the CaBr molecule was monitored at 625315 nm with integration of the central pixel +/- 1. Bromine quantification by LA-ICP-MS was performed via external calibration against a single CRM while using the C-12(+) signal as an internal standard. With HR-CS SS-GF MAS, Br quantification could be accomplished using external calibration against aqueous standard solutions. Except for one LA-IC-PMS result, the concentrations obtained with both techniques were in agreement with the certified values within the experimental uncertainty as evidenced using a t-test (95% confidence level). The limit of quantification was determined to be 100 jig g(-1) Br for LA-ICP-MS and 100 mu g(-1) Br for HR-CS SS-GF MAS. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:50 / 55
页数:6
相关论文
共 50 条
  • [31] Determination of chlorine in food samples via the AlCl molecule using high-resolution continuum source molecular absorption spectrometry in a graphite furnace
    Fechetia, Miriam
    Tognon, Andre Luiz
    da Veiga, Marcia A. M. S.
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2012, 71-72 : 98 - 101
  • [32] Considerations on data acquisition in laser ablation-inductively coupled plasma-mass spectrometry with low-dispersion interfaces
    Van Malderen, Stijn J. M.
    van Elteren, Johannes T.
    Selih, Vid S.
    Vanhaecke, Frank
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2018, 140 : 29 - 34
  • [33] Trace element characteristics in the diopsides of peridotite xenoliths: a laser ablation-inductively coupled plasma-mass spectrometry study
    CHEN Shaohai 1
    2. GEMOC
    ChineseScienceBulletin, 1998, (07) : 579 - 583
  • [34] Development of a comprehensive method for hair and nail analysis using laser ablation-inductively coupled plasma-mass spectrometry
    Chan, Yun-Nam
    Lum, Judy Tsz-Shan
    Leung, Kelvin Sze-Yin
    MICROCHEMICAL JOURNAL, 2023, 188
  • [35] Natural Obsidian Glass as an External Accuracy Reference Material in Laser Ablation-Inductively Coupled Plasma-Mass Spectrometry
    Ulrich, Thomas
    Kamber, Balz S.
    GEOSTANDARDS AND GEOANALYTICAL RESEARCH, 2013, 37 (02) : 169 - 188
  • [36] Differentiation of clay-based pigments in paintings by means of laser ablation-inductively coupled plasma-mass spectrometry
    Pospisilova, Eva
    Hradil, David
    Hola, Marketa
    Hradilova, Janka
    Novotny, Karel
    Kanicky, Viktor
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2019, 158
  • [37] Quantification strategies for elemental imaging of biological samples using laser ablation-inductively coupled plasma-mass spectrometry
    Hare, Dominic
    Austin, Christine
    Doble, Philip
    ANALYST, 2012, 137 (07) : 1527 - 1537
  • [38] High-speed mapping of Hg and Se in biological tissue via laser ablation-inductively coupled plasma-mass spectrometry
    Van Helden, Tom
    Braeuer, Simone
    Van Acker, Thibaut
    Leroux, Olivier
    Van Der Straeten, Dominique
    Vanhaecke, Frank
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2022, 37 (07) : 1455 - 1461
  • [39] Direct analysis of bromine and iodine in dried serum spots by laser ablation inductively coupled plasma mass spectrometry
    He, Jing
    Li, A-Fang
    Han, Hua-yun
    Su, Shuang
    Zhang, Pei
    Zhang, Er-peng
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2020, 34 (04)
  • [40] Determination of Total Sulfur in Food Samples by Solid Sampling High-Resolution Continuum Source Graphite Furnace Molecular Absorption Spectrometry
    Ozbek, Nil
    Akman, Suleyman
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2013, 61 (20) : 4816 - 4821