A comparison of laser ablation-inductively coupled plasma-mass spectrometry and high-resolution continuum source graphite furnace molecular absorption spectrometry for the direct determination of bromine in polymers

被引:14
|
作者
de Gois, Jefferson S. [1 ,2 ,3 ]
Van Malderen, Stijn J. M. [2 ]
Cadorim, Heloisa R. [1 ]
Welz, Bernhard [1 ,4 ]
Vanhaecke, Frank [2 ]
机构
[1] Univ Fed Santa Catarina, Dept Chem, Florianopolis, SC, Brazil
[2] Univ Ghent, Dept Analyt Chem, Ghent, Belgium
[3] Univ Estado Rio De Janeiro, Dept Analyt Chem, Rio De Janeiro, Brazil
[4] Univ Fed Bahia, Inst Nacl Ciencia & Tecnol, INCT Energia & Ambiente, CNPq, Salvador, BA, Brazil
关键词
Bromine; Polymer; Halogen; LA-ICP-MS; HR-CS GF MAS; LA-ICP-MS; SOLID SAMPLE ANALYSIS; FLAME RETARDANTS; DIGESTION; HALOGENS; CHLORINE; SULFUR; CARBON; SIZE;
D O I
10.1016/j.sab.2017.04.003
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
This work describes the development and comparison.of two methods for the direct determination of Br in polymer samples via solid sampling, one using laser ablation-inductively coupled plasma-mass spectrometry (LA-ICP-MS) and the other using high-resolution continuum source graphite furnace molecular absorption spectrometry with direct solid sample analysis (HR-CS SS-GF MAS). The methods were optimized and their accuracy was evaluated by comparing the results obtained for 6 polymeric certified reference materials (CRMs) with the corresponding certified values. For Br determination with LA-ICP-MS, the 79Br signal could be monitored interference-free. For Br determination via HR-CS SS-GF MAS, the CaBr molecule was monitored at 625315 nm with integration of the central pixel +/- 1. Bromine quantification by LA-ICP-MS was performed via external calibration against a single CRM while using the C-12(+) signal as an internal standard. With HR-CS SS-GF MAS, Br quantification could be accomplished using external calibration against aqueous standard solutions. Except for one LA-IC-PMS result, the concentrations obtained with both techniques were in agreement with the certified values within the experimental uncertainty as evidenced using a t-test (95% confidence level). The limit of quantification was determined to be 100 jig g(-1) Br for LA-ICP-MS and 100 mu g(-1) Br for HR-CS SS-GF MAS. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:50 / 55
页数:6
相关论文
共 50 条
  • [1] Determination of bromine using high-resolution continuum source molecular absorption spectrometry in a graphite furnace
    Limburg, Tobias
    Einax, Jurgen W.
    MICROCHEMICAL JOURNAL, 2013, 107 : 31 - 36
  • [2] Direct determination of bromine in plastic materials by means of solid sampling high-resolution continuum source graphite furnace molecular absorption spectrometry
    Florez, M. R.
    Resano, M.
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2013, 88 : 32 - 39
  • [3] Characterization of Paintings by Laser Ablation-Inductively Coupled Plasma-Mass Spectrometry
    Marin, E.
    Padro, A.
    Miquel, A.
    Garcia, Jose F.
    ANALYTICAL LETTERS, 2015, 48 (01) : 167 - 179
  • [4] Laser Ablation-Inductively Coupled Plasma-Mass Spectrometry Imaging in Biology
    Doble, Philip A.
    de Vega, Raquel Gonzalez
    Bishop, David P.
    Hare, Dominic J.
    Clases, David
    CHEMICAL REVIEWS, 2021, 121 (19) : 11769 - 11822
  • [5] Determination of chlorine via the CaCl molecule by high-resolution continuum source graphite furnace molecular absorption spectrometry and direct solid sample analysis
    Guarda, Ananda
    Araniendia, Maite
    Andres, Irene
    Garcia-Ruiz, Esperanza
    do Nascimento, Paulo Cicero
    Resano, Martin
    TALANTA, 2017, 162 : 354 - 361
  • [6] High spatial resolution quantitative elemental imaging of foraminifer by laser ablation-inductively coupled plasma-mass spectrometry
    Ke, Yuqiu
    Zhou, Jianzong
    Qiao, Lei
    Zhang, Muhui
    Guo, Wei
    Jin, Lanlan
    Hu, Shenghong
    ANALYTICAL METHODS, 2019, 11 (16) : 2129 - 2137
  • [7] Method development for the determination of bromine in coal using high-resolution continuum source graphite furnace molecular absorption spectrometry and direct solid sample analysis
    Pereira, Ederson R.
    Castilho, Ivan N. B.
    Welz, Bernhard
    Gois, Jefferson S.
    Borges, Daniel L. G.
    Carasek, Eduardo
    de Andrade, Jailson B.
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2014, 96 : 33 - 39
  • [8] Analysis of Some Chinese Potash Glass by Laser Ablation-Inductively Coupled Plasma-Atomic Emission Spectrometry and Laser Ablation-Inductively Coupled Plasma-Mass Spectrometry
    Siqin, Bilige
    Li Qing-Hui
    Gan Fu-Xi
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2013, 41 (09) : 1328 - 1333
  • [9] High-resolution laser ablation-inductively coupled plasma-mass spectrometry imaging of cisplatin-induced nephrotoxic side effects
    Van Acker, Thibaut
    Van Malderen, Stijn J. M.
    Van Heerden, Marjolein
    McDuffie, James Eric
    Cuyckens, Filip
    Vanhaecke, Frank
    ANALYTICA CHIMICA ACTA, 2016, 945 : 23 - 30
  • [10] Determination of Chlorine in Milk via Molecular Absorption of SrCI Using High-Resolution Continuum Source Graphite Furnace Atomic Absorption Spectrometry
    Ozbek, Nil
    Akman, Suleyman
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2016, 64 (28) : 5767 - 5772