The Analysis of Anionic Surfactants in Effluents Using a DDA-TPB Potentiometric Sensor

被引:0
|
作者
Samardzic, Mirela [1 ]
Galovic, Olivera [1 ]
Petrusic, Sanja [1 ]
Sak-Bosnar, Milan [1 ]
机构
[1] Josip Juraj Strossmayer Univ Osijek, Dept Chem, HR-31000 Osijek, Croatia
来源
INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE | 2014年 / 9卷 / 11期
关键词
surfactant sensor; dimethyldioctadecylammonium-tetraphenylborate ion pair; anionic surfactant; potentiometric titration; industrial effluents; FLOW-INJECTION ANALYSIS; INDUSTRIAL EFFLUENTS; SENSITIVE ELECTRODE; SELECTIVE ELECTRODE; RIVER WATER; TITRATION; PRODUCTS; DETERGENTS; MIXTURE; MATRIX;
D O I
暂无
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
A new, simple, sensitive, accurate and inexpensive potentiometric sensor for the determination of anionic surfactants (AS) based on the dimethyldioctadecylammonium-tetraphenylborate (DDA-TPB) ion pair as a sensing material was used for end-point detection during the potentiometric titrations of low levels of AS in industrial effluents. Solutions of cetylpyridinium chloride (CPC) at concentrations as low as 5.10(-5) M were successfully used as a titrant. The accuracy and precision of the measurements were determined using the standard addition method, and satisfactory results were obtained, with recoveries between 98.3 to 102.0 % in pure AS solutions and 99.0 to 114.5 % in effluents. The AS concentration in effluents ranged between 2.64 and 176.7 mg/L. The results were compared with a standard spectrophotometric Methylene Blue Active Substances (MBAS) method, and they indicated a satisfactory correlation. The influence of the different pH values (2-10) and ionic strengths (0.003-0.301) on the shape of the potentiometric titration curves and the response characteristics of the sensor were examined.
引用
收藏
页码:6166 / 6181
页数:16
相关论文
共 12 条
  • [1] Potentiometric Titration of Micromolar Levels of Anionic Surfactants in Model Effluents Using a Sensitive Potentiometric Sensor
    Galovic, Olivera
    Samardzic, Mirela
    Derezic, Dragan
    Madunic-Cacic, Dubravka
    Sak-Bosnar, Milan
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2012, 7 (02): : 1522 - 1531
  • [2] New potentiometric sensor for determination of low levels of anionic surfactants in industrial effluents
    Sak-Bosnar, M
    Matesic-Puac, R
    Madunic-Cacic, D
    Grabaric, Z
    TENSIDE SURFACTANTS DETERGENTS, 2006, 43 (02) : 82 - 87
  • [3] Determination of Anionic Surfactants in Industrial Effluents Using a New Highly Sensitive Surfactant-Selective Sensor
    Madunic-Cacic, Dubravka
    Sak-Bosnar, Milan
    Samardzic, Mirela
    Grabaric, Zorana
    SENSOR LETTERS, 2009, 7 (01) : 50 - 56
  • [4] Application of a New Potentiometric Sensor for Determination of Anionic Surfactants in Wastewater
    Galovic, O.
    Samardzic, M.
    Petrusic, S.
    Sak-Bosnar, M.
    CHEMICAL AND BIOCHEMICAL ENGINEERING QUARTERLY, 2015, 29 (03) : 307 - 313
  • [5] Determination of anionic surfactants in environmental waters by flow injection potentiometric analysis
    Wang, YJ
    Guan, S
    Hao, D
    Dan, DZ
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2002, 30 (12) : 1455 - 1458
  • [6] Determination of cationic surfactants in pharmaceutical disinfectants using a new sensitive potentiometric sensor
    Madunic-Cacic, Dubravka
    Sak-Bosnar, Milan
    Galovic, Olivera
    Sakac, Nikola
    Matesic-Puac, Ruzica
    TALANTA, 2008, 76 (02) : 259 - 264
  • [7] Potentiometric determination of anionic surfactants using a new ion-pair-based all-solid-state surfactant sensitive electrode
    Matesic-Puac, R
    Sak-Bosnar, M
    Bilic, M
    Grabaric, BS
    SENSORS AND ACTUATORS B-CHEMICAL, 2005, 106 (01): : 221 - 228
  • [8] Analysis of mercury ions in effluents using potentiometric sensor based on nanocomposite cation exchanger Polyaniline-zirconium titanium phosphate
    Khan, Asif Ali
    Paquiza, Leena
    DESALINATION, 2011, 272 (1-3) : 278 - 285
  • [9] Potentiometric Surfactant Sensor Based on 1,3-Dihexadecyl-1H-benzo[d]imidazol-3-ium for Anionic Surfactants in Detergents and Household Care Products
    Sakac, Nikola
    Madunic-Cacic, Dubravka
    Markovic, Dean
    Hok, Lucija
    Vianello, Robert
    Sarkanj, Bojan
    Durin, Bojan
    Hajdek, Krunoslav
    Smoljan, Bozo
    Milardovic, Stjepan
    Matasovic, Brunislav
    Jozanovic, Marija
    MOLECULES, 2021, 26 (12):
  • [10] In vitro Analysis of the Effect of Alkyl-Chain Length of Anionic Surfactants on the Skin by Using a Reconstructed Human Epidermal Model
    Yamaguchi, Fumiko
    Watanabe, Shin-ichi
    Harada, Fusae
    Miyake, Miyuki
    Yoshida, Masaki
    Okano, Tomomichi
    JOURNAL OF OLEO SCIENCE, 2014, 63 (10) : 995 - 1004