Calibration and field application of passive sampling for episodic exposure to polar organic pesticides in streams

被引:42
|
作者
Fernandez, Diego [1 ]
Vermeirssen, Etienne L. M. [2 ]
Bandow, Nicole [3 ]
Munoz, Katherine [1 ]
Schaefer, Ralf B. [1 ]
机构
[1] Univ Koblenz Landau, Inst Environm Sci, D-76829 Landau, Germany
[2] EPFL, Swiss Ctr Appl Ecotoxicol Eawag, CH-8600 Dubendorf, Switzerland
[3] Fed Inst Mat Res & Testing, D-12205 Berlin, Germany
关键词
Passive sampling; Pesticide; Water monitoring; Freshwater; SURFACE WATERS; SEMIPOLAR PESTICIDES; DEGRADATION-PRODUCTS; SAMPLERS; CHEMCATCHER; POLLUTANTS; CATCHMENT; FUNGICIDES; PERFORMANCE; KINETICS;
D O I
10.1016/j.envpol.2014.08.001
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Rainfall-triggered runoff is a major driver of pesticide input in streams. Only few studies have examined the suitability of passive sampling to quantify such episodic exposures. In this study, we used Empore(TM) styrene-divinylbenzene reverse phase sulfonated disks (SDB disks) and event-driven water samples (EDS) to assess exposure to 15 fungicides and 4 insecticides in 17 streams in a German vineyard area during 4 rainfall events. We also conducted a microcosm experiment to determine the SDB-disk sampling rates and provide a free-software solution to derive sampling rates under time-variable exposure. Sampling rates ranged from 0.26 to 0.77 L d(-1) and time-weighted average (TWA) concentrations from 0.05 to 2.11 mu g/L. The 2 sampling systems were in good agreement and EDS exceeded TWA concentrations on average by a factor of 3. Our study demonstrates that passive sampling is suitable to quantify episodic exposures from polar organic pesticides. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:196 / 202
页数:7
相关论文
共 50 条
  • [1] Calibration and field application of the Atlantic HLB Disk containing Chemcatcher® passive sampler - Quantitative monitoring of herbicides, other pesticides, and transformation products in German streams
    Grodtke, Mara
    Paschke, Albrecht
    Harzdorf, Julia
    Krauss, Martin
    Schueuermann, Gerrit
    JOURNAL OF HAZARDOUS MATERIALS, 2021, 410
  • [2] Passive sampling of selected pesticides in aquatic environment using polar organic chemical integrative samplers
    Thomatou, Anna-Akrivi
    Zacharias, Ierotheos
    Hela, Dimitra
    Konstantinou, Ioannis
    ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2011, 18 (07) : 1222 - 1233
  • [3] Sampling rates for passive samplers exposed to a field-relevant peak of 42 organic pesticides
    Schreiner, Verena C.
    Bakanov, Nikita
    Kattwinkel, Mira
    Konemann, Sarah
    Kunz, Stefan
    Vermeirssen, Etienne L. M.
    Schafer, Ralf B.
    SCIENCE OF THE TOTAL ENVIRONMENT, 2020, 740
  • [4] Concentrations, fluxes and field calibration of passive water samplers for pesticides and hazard-based risk assessment
    Ahrens, Lutz
    Daneshvar, Atlasi
    Lau, Anna E.
    Kreuger, Jenny
    SCIENCE OF THE TOTAL ENVIRONMENT, 2018, 637 : 835 - 843
  • [5] Field application of passive SBSE for the monitoring of pesticides in surface waters
    Assoumani, A.
    Coquery, M.
    Liger, L.
    Mazzella, N.
    Margoum, C.
    ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2015, 22 (06) : 3997 - 4008
  • [6] Passive sampling of selected pesticides in aquatic environment using polar organic chemical integrative samplers
    Αnna-Αkrivi Thomatou
    Ierotheos Zacharias
    Dimitra Hela
    Ioannis Konstantinou
    Environmental Science and Pollution Research, 2011, 18 : 1222 - 1233
  • [7] Trends in the use of passive sampling for monitoring polar pesticides in water
    Taylor, Adam C.
    Fones, Gary R.
    Mills, Graham A.
    TRENDS IN ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2020, 27
  • [8] Modelling and field application of the Chemcatcher passive sampler calibration data for the monitoring of hydrophobic organic pollutants in water
    Vrana, Branislav
    Mills, Graham A.
    Kotterman, Michiel
    Leonards, Pim
    Booij, Kees
    Greenwood, Richard
    ENVIRONMENTAL POLLUTION, 2007, 145 (03) : 895 - 904
  • [9] In-situ calibration of a microporous polyethylene passive sampling device with polar organic micropollutants in the Chillan River, central Chile
    Cardenas-Soraca, Diana M.
    Barra-Rios, Ricardo O.
    Mueller, Jochen F.
    Hawker, Darryl W.
    Kaserzon, Sarit L.
    ENVIRONMENTAL RESEARCH, 2020, 188
  • [10] Calibration and field performance of triolein embedded acetate membranes for passive sampling persistent organic pollutants in water
    Tang, Jianfeng
    Chen, Shan
    Xu, Yiping
    Zhong, Wenjue
    Ma, Mei
    Wang, Zijian
    ENVIRONMENTAL POLLUTION, 2012, 164 : 158 - 163