Comparison of Iodixanol and Ioxaglate for Coronary Optical Coherence Tomography Imaging

被引:0
作者
Christakopoulos, Georgios E.
Kotsia, Anna P.
Christopoulos, Georgios
Abdullah, Shuaib M.
Rangan, Bavana V.
Roesle, Michele
Banerjee, Subhash
Brilakis, Emmanouil S.
机构
[1] VA North Texas Hlth Care Syst, Dallas, TX USA
[2] Univ Texas SW Med Ctr Dallas, Dallas, TX 75390 USA
关键词
coronary artery disease; cardiac imaging; radiographic contrast; iodixanol; ioxaglate; MOLECULAR-WEIGHT DEXTRAN; INTRAVASCULAR ULTRASOUND; CONTRAST-MEDIA; ATHEROSCLEROSIS; OCCLUSION; PLAQUE;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. The impact of contrast type on coronary imaging using optical coherence tomography (OCT) has received limited study. We compared OCT imaging obtained using the non-ionic, iso-osmolar iodixanol with the ionic, low-osmolar ioxaglate. Methods. Twenty-two vessels in 20 patients were imaged twice using manual injection of iodixanol and ioxaglate in random order. OCT images were analyzed at 1 mm intervals to determine lumen area, artifact diameter and area, as well as stent strut coverage and malapposition in OCT pullbacks that included stents. Results. There were no complications related to OCT imaging or to contrast administration. A total of 2184 cross-sections (1092 with iodixanol and 1092 with ioxaglate) were analyzed. Compared with iodixanol, imaging using ioxaglate provided similar mean lumen area (6.21 +/- 2.83 mm(2) vs 6.27 +/- 2.83 mm(2); Spearman's rho, 0.982), mean minimum lumen diameter (2.47 +/- 0.59 mm vs 2.50 +/- 0.58 mm; Spearman's rho, 0.939), and mean maximum lumen diameter (2.99 +/- 0.71 mm vs 3.01 +/- 0.70 mm; Spearman's rho, 0.964), but lower mean artifact area per cross-section (0.099 +/- 0.325 mm(2) vs 0.068 +/- 0.329 mm(2); P<.001). Analyses of 3303 stent struts in 388 cross-sections (194 with iodixanol and 194 with ioxaglate) demonstrated similar strut malapposition rates (11.82% vs 13.90%; P=.10) and strut coverage (41.92% vs 40.33%; P=.35). Conclusions. Compared with iodixanol, OCT imaging using ioxaglate provided similar lumen and diameter measurements and stent strut characterization, but smaller area of artifact.
引用
收藏
页码:E287 / E290
页数:4
相关论文
共 50 条
  • [41] Conformational Change in Coronary Artery Structure Assessed by Optical Coherence Tomography in Patients With Vasospastic Angina
    Tanaka, Atsushi
    Shimada, Kenei
    Tearney, Guillermo J.
    Kitabata, Hironori
    Taguchi, Haruyuki
    Fukuda, Shota
    Kashiwagi, Manabu
    Kubo, Takashi
    Takarada, Shigeho
    Hirata, Kumiko
    Mizukoshi, Masato
    Yoshikawa, Junichi
    Bouma, Brett E.
    Akasaka, Takashi
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 58 (15) : 1608 - 1613
  • [42] Automated Coronary Optical Coherence Tomography Feature Extraction with Application to Three-Dimensional Reconstruction
    Carpenter, Harry J.
    Ghayesh, Mergen H.
    Zander, Anthony C.
    Li, Jiawen
    Di Giovanni, Giuseppe
    Psaltis, Peter J.
    TOMOGRAPHY, 2022, 8 (03) : 1307 - 1349
  • [43] COMPARISON OF ANGIOGRAPHIC OPACIFICATION OF IOXAGLATE AND IODIXANOL BY DIGITAL REGION-OF-INTEREST PROCESSING TECHNIQUE IN AN EXPERIMENTAL CIRCULATION MODEL
    YANG, XM
    MANNINEN, H
    SOIMAKALLIO, S
    INVESTIGATIVE RADIOLOGY, 1994, 29 (01) : 31 - 34
  • [44] Imaging assessment and accuracy in coronary artery autopsy: comparison of frequency-domain optical coherence tomography with intravascular ultrasound and histology
    Aiko Shimokado
    Takashi Kubo
    Yoshiki Matsuo
    Yasushi Ino
    Yasutsugu Shiono
    Kunihiro Shimamura
    Yosuke Katayama
    Akira Taruya
    Tsuyoshi Nishiguchi
    Manabu Kashiwagi
    Hironori Kitabata
    Atsushi Tanaka
    Takeshi Hozumi
    Takashi Akasaka
    The International Journal of Cardiovascular Imaging, 2019, 35 : 1785 - 1790
  • [45] Imaging assessment and accuracy in coronary artery autopsy: comparison of frequency-domain optical coherence tomography with intravascular ultrasound and histology
    Shimokado, Aiko
    Kubo, Takashi
    Matsu, Yoshiki
    Ino, Yasushi
    Shiono, Yasutsugu
    Shimamura, Kunihiro
    Katayama, Yosuke
    Taruya, Akira
    Nishiguchi, Tsuyoshi
    Kashiwagi, Manabu
    Kitabata, Hironori
    Tanaka, Atsushi
    Hozumi, Takeshi
    Akasaka, Takashi
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2019, 35 (10) : 1785 - 1790
  • [46] Comparison of quantitative calcium parameters between optical coherence tomography and invasive coronary angiography
    McGuire, Colin
    Shlofmitz, Evan
    Melaku, Gebremedhin D.
    Kuku, Kayode O.
    Kahsay, Yirga
    Shlofmitz, Richard
    Jeremias, Allen
    Garcia-Garcia, Hector M.
    REC-INTERVENTIONAL CARDIOLOGY, 2022, 4 (01): : 6 - 11
  • [47] Predictors for Rapid Progression of Coronary Calcification: An Optical Coherence Tomography Study
    Nakajima, Akihiro
    Araki, Makoto
    Kurihara, Osamu
    Minami, Yoshiyasu
    Soeda, Tsunenari
    Yonetsu, Taishi
    Higuma, Takumi
    Kakuta, Tsunekazu
    McNulty, Iris
    Lee, Hang
    Malhotra, Rajeev
    Nakamura, Sunao
    Jang, Ik-Kyung
    JOURNAL OF THE AMERICAN HEART ASSOCIATION, 2021, 10 (03): : 1 - 13
  • [48] Combined Imaging and Functional Assessment in Percutaneous Coronary Intervention: Is Coronary Optical Coherence Tomography Emerging as a PCI Panacea?
    Kay, Robert T.
    Kim, Daniel H.
    CANADIAN JOURNAL OF CARDIOLOGY, 2025, 41 (01) : 9 - 11
  • [49] Current status of hybrid intravascular ultrasound and optical coherence tomography catheter for coronary imaging and percutaneous coronary intervention
    Terashima, Mitsuyasu
    Kaneda, Hideaki
    Honda, Yasuhiro
    Shimura, Tetsuro
    Kodama, Atsuko
    Habara, Maoto
    Suzuki, Takahiko
    JOURNAL OF CARDIOLOGY, 2021, 77 (05) : 435 - 443
  • [50] Optical coherence tomography to guide percutaneous coronary intervention
    Almajid, Faisal
    Kang, Do-Yoon
    Ahn, Jung-Min
    Park, Seung-Jung
    Park, Duk-Woo
    EUROINTERVENTION, 2024, 20 (19) : e1202 - e1216