Comparison of Iodixanol and Ioxaglate for Coronary Optical Coherence Tomography Imaging

被引:0
作者
Christakopoulos, Georgios E.
Kotsia, Anna P.
Christopoulos, Georgios
Abdullah, Shuaib M.
Rangan, Bavana V.
Roesle, Michele
Banerjee, Subhash
Brilakis, Emmanouil S.
机构
[1] VA North Texas Hlth Care Syst, Dallas, TX USA
[2] Univ Texas SW Med Ctr Dallas, Dallas, TX 75390 USA
关键词
coronary artery disease; cardiac imaging; radiographic contrast; iodixanol; ioxaglate; MOLECULAR-WEIGHT DEXTRAN; INTRAVASCULAR ULTRASOUND; CONTRAST-MEDIA; ATHEROSCLEROSIS; OCCLUSION; PLAQUE;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. The impact of contrast type on coronary imaging using optical coherence tomography (OCT) has received limited study. We compared OCT imaging obtained using the non-ionic, iso-osmolar iodixanol with the ionic, low-osmolar ioxaglate. Methods. Twenty-two vessels in 20 patients were imaged twice using manual injection of iodixanol and ioxaglate in random order. OCT images were analyzed at 1 mm intervals to determine lumen area, artifact diameter and area, as well as stent strut coverage and malapposition in OCT pullbacks that included stents. Results. There were no complications related to OCT imaging or to contrast administration. A total of 2184 cross-sections (1092 with iodixanol and 1092 with ioxaglate) were analyzed. Compared with iodixanol, imaging using ioxaglate provided similar mean lumen area (6.21 +/- 2.83 mm(2) vs 6.27 +/- 2.83 mm(2); Spearman's rho, 0.982), mean minimum lumen diameter (2.47 +/- 0.59 mm vs 2.50 +/- 0.58 mm; Spearman's rho, 0.939), and mean maximum lumen diameter (2.99 +/- 0.71 mm vs 3.01 +/- 0.70 mm; Spearman's rho, 0.964), but lower mean artifact area per cross-section (0.099 +/- 0.325 mm(2) vs 0.068 +/- 0.329 mm(2); P<.001). Analyses of 3303 stent struts in 388 cross-sections (194 with iodixanol and 194 with ioxaglate) demonstrated similar strut malapposition rates (11.82% vs 13.90%; P=.10) and strut coverage (41.92% vs 40.33%; P=.35). Conclusions. Compared with iodixanol, OCT imaging using ioxaglate provided similar lumen and diameter measurements and stent strut characterization, but smaller area of artifact.
引用
收藏
页码:E287 / E290
页数:4
相关论文
共 50 条
  • [31] Imaging human coronary cholesterol/urate crystals with cross-polarized micro-optical coherence tomography
    Nishimiya, Kensuke
    Sharma, Gargi
    Singh, Kanwarpal
    Ahsen, Osman O.
    Gardecki, Joseph A.
    Tearney, Guillermo J.
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2024, 11
  • [32] Imaging vascular implants with optical coherence tomography
    Barton, JK
    Dal Fonte, DB
    Williams, SK
    Ford, B
    Descour, MR
    COHERENCE DOMAIN OPTICAL METHODS IN BIOMEDICAL SCIENCE AND CLINICAL APPLICATIONS IV, 2000, 3915 : 229 - 236
  • [33] Optical Coherence Tomography
    McCabe, James M.
    Croce, Kevin J.
    CIRCULATION, 2012, 126 (17) : 2140 - 2143
  • [34] Optical coherence tomography imaging of cardiac substrates
    Hendon, Christine P.
    Lye, Theresa H.
    Yao, Xinwen
    Gan, Yu
    Marboe, Charles C.
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2019, 9 (05) : 882 - 904
  • [35] Accuracy of coronary computed tomography angiography for bioresorbable scaffold luminal investigation: a comparison with optical coherence tomography
    Collet, Carlos
    Sotomi, Yohei
    Cavalcante, Rafael
    Asano, Taku
    Miyazaki, Yosuke
    Tenekecioglu, Erhan
    Kistlaar, Pieter
    Zeng, Yaping
    Suwanasson, Pannipa
    de Winter, Robbert J.
    Nieman, Koen
    Serruys, Patrick W.
    Onuma, Yoshinobu
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2017, 33 (03) : 431 - 439
  • [36] Comparison Between Cardiac Allograft Vasculopathy and Native Coronary Atherosclerosis by Optical Coherence Tomography
    Shan, Peiren
    Dong, Liang
    Maehara, Akiko
    Nazif, Tamim M.
    Ali, Ziad A.
    Rabbani, LeRoy E.
    Apfelbaum, Mark A.
    Dalton, Kate
    Marboe, Charles C.
    Mancini, Donna M.
    Mintz, Gary S.
    Weisz, Giora
    AMERICAN JOURNAL OF CARDIOLOGY, 2016, 117 (08) : 1361 - 1368
  • [37] Optical Coherence Tomography Characterization of Coronary Lithoplasty for Treatment of Calcified Lesions
    Ali, Ziad A.
    Brinton, Todd J.
    Hill, Jonathan M.
    Maehara, Akiko
    Matsumura, Mitsuaki
    Galougahi, Keyvan Karimi
    Illindala, Uday
    Gotberg, Matthias
    Whitbourn, Robert
    Van Mieghem, Nicolas
    Meredith, Ian T.
    Di Mario, Carlo
    Fajadet, Jean
    JACC-CARDIOVASCULAR IMAGING, 2017, 10 (08) : 897 - 906
  • [38] Optical coherence tomography and coronary revascularization: from indication to procedural optimization
    Volleberg, Rick
    Mol, Jan-Quinten
    van der Heijden, Dirk
    Meuwissen, Martijn
    van Leeuwen, Maarten
    Escaned, Javier
    Holm, Niels
    Adriaenssens, Tom
    van Geuns, Robert Jan
    Tu, Shengxian
    Crea, Filippo
    Stone, Gregg
    van Royen, Niels
    TRENDS IN CARDIOVASCULAR MEDICINE, 2023, 33 (02) : 92 - 106
  • [39] Coronary optical coherence tomography: A practical overview of current clinical applications
    Ferreira, Rui Cruz
    Pereira-da-Silva, Tiago
    Patricio, Lino
    Bezerra, Hiram
    Costa, Marco
    REVISTA PORTUGUESA DE CARDIOLOGIA, 2016, 35 (02) : 105 - 112
  • [40] Optical coherence tomography revisited: imaging and imagination
    Rai, Himanshu
    Cassese, Salvatore
    Joner, Michael
    EUROINTERVENTION, 2018, 14 (10) : 1080 - 1083