Determining the porous structure for optimal soft-tissue ingrowth: An in vivo histological study

被引:24
作者
Chimutengwende-Gordon, Mukai [1 ]
Dowling, Robert [1 ]
Pendegrass, Catherine [1 ]
Blunn, Gordon [1 ]
机构
[1] Univ Coll London, Royal Natl Orthopaed Hosp Trust, Inst Orthopaed & Musculoskeletal Sci, John Scales Ctr Biomed Engn, Brockley Hill, Stanmore, Middx, England
关键词
TITANIUM IMPLANTS; FIBROUS TISSUE; PORE-SIZE; PROSTHESES; ATTACHMENT; AMPUTEES; BARRIER;
D O I
10.1371/journal.pone.0206228
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
The success of osseointegrated transcutaneous prostheses depends on a soft-tissue seal forming at the skin-implant interface in order to prevent infection. Current designs include a flange with drilled holes or a subdermal barrier with a porous coating in an attempt to promote soft-tissue attachment. However, the soft-tissue seal is not reliably achieved despite these designs and infection remains a significant problem. This study investigated soft-tissue integration into fully porous titanium alloy structures with interconnected pores. The study aimed to determine the effect of altering pore and strut size combinations on soft-tissue ingrowth into porous titanium alloy structures in vivo. It was hypothesized that implants with a more open porous structure with larger pore sizes would increase soft-tissue ingrowth more than less open porous structures. Porous titanium alloy cylinders were inserted into sheep paparaspinal muscles (n = 6) and left in situ for four weeks. A histological assessment of soft-tissue ingrowth was performed. Percentage soft-tissue pore fill, cell nuclei density and blood vessel density were quantified. The results showed that larger pore sizes were supportive of soft-tissue ingrowth. A structure with a pore size of 700 mu m and a strut size of 300 mu m supported revascularisation to the greatest degree. A flange with this structure may be used in future studies of osseointegrated transcutaneous prostheses in order to enhance the soft-tissue seal.
引用
收藏
页数:17
相关论文
共 26 条
[1]  
Alberts B., 2002, Molecular Biology of the Cell. (4th edition), V4th ed
[2]   OSSEOINTEGRATED TITANIUM IMPLANTS - REQUIREMENTS FOR ENSURING A LONG-LASTING, DIRECT BONE-TO-IMPLANT ANCHORAGE IN MAN [J].
ALBREKTSSON, T ;
BRANEMARK, PI ;
HANSSON, HA ;
LINDSTROM, J .
ACTA ORTHOPAEDICA SCANDINAVICA, 1981, 52 (02) :155-170
[3]  
BOBYN JD, 1980, CLIN ORTHOP RELAT R, P263
[4]   EFFECT OF PORE-SIZE ON THE PEEL STRENGTH OF ATTACHMENT OF FIBROUS TISSUE TO POROUS-SURFACED IMPLANTS [J].
BOBYN, JD ;
WILSON, GJ ;
MACGREGOR, DC ;
PILLIAR, RM ;
WEATHERLY, GC .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1982, 16 (05) :571-584
[5]   TITANIUM IMPLANTS PERMANENTLY PENETRATING HUMAN-SKIN [J].
BRANEMARK, PI ;
ALBREKTSSON, T .
SCANDINAVIAN JOURNAL OF PLASTIC AND RECONSTRUCTIVE SURGERY AND HAND SURGERY, 1982, 16 (01) :17-21
[6]  
Brånemark R, 2001, J REHABIL RES DEV, V38, P175
[7]   Fibroblastic interactions with high-porosity Ti-6Al-4V metal foam [J].
Cheung, Serene ;
Gauthier, Maxime ;
Lefebvre, Louis-Philippe ;
Dunbar, Michael ;
Filiaggi, Mark .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2007, 82B (02) :440-449
[8]   A knee-sparing distal femoral endoprosthesis using hydroxyrapatite-coated extracortical plates - Preliminary results [J].
Gupta, A. ;
Pollock, R. ;
Cannon, S. R. ;
Briggs, T. W. R. ;
Skinner, J. ;
Blunn, G. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2006, 88B (10) :1367-1372
[9]  
Hacking SA, 2000, J BIOMED MATER RES, V52, P631
[10]   Cellular Ti-6Al-4V structures with interconnected macro porosity for bone implants fabricated by selective electron beam melting [J].
Heinl, Peter ;
Mueller, Lenka ;
Koerner, Carolin ;
Singer, Robert F. ;
Mueller, Frank A. .
ACTA BIOMATERIALIA, 2008, 4 (05) :1536-1544