Is quantitative coronary angiography reliable in assessing the late lumen loss of the everolimus-eluting bioresorbable polylactide scaffold in comparison with the cobalt-chromium metallic stent?

被引:5
|
作者
Sotomi, Yohei [1 ]
Onuma, Yoshinobu [2 ,3 ]
Miyazaki, Yosuke [2 ]
Asano, Taku [1 ]
Katagiri, Yuki [1 ]
Tenekecioglu, Erhan [2 ]
Jonker, Hans [3 ]
Dijkstra, Jouke [4 ]
de Winter, Robbert J. [1 ]
Wykrzykowska, Joanna J. [1 ]
Stone, Gregg W. [5 ,6 ]
Popma, Jeffrey J. [7 ]
Kozuma, Ken [8 ]
Tanabe, Kengo [9 ]
Serruys, Patrick W. [10 ]
Kimura, Takeshi [11 ]
机构
[1] Univ Amsterdam, Acad Med Ctr, Amsterdam, Netherlands
[2] Erasmus MC, Thoraxctr, Rotterdam, Netherlands
[3] Cardialysis, Rotterdam, Netherlands
[4] Leiden Univ, Med Ctr, Dept Radiol, LKEB Div Image Proc, Leiden, Netherlands
[5] Columbia Univ, New York Presbyterian Hosp, Med Ctr, New York, NY 10027 USA
[6] Cardiovasc Res Fdn, New York, NY USA
[7] Beth Israel Deaconess Med Ctr, Boston, MA 02215 USA
[8] Teikyo Univ Hosp, Tokyo, Japan
[9] Mitsui Mem Hosp, Cardiac Intens Care Unit, Div Cardiol, Tokyo, Japan
[10] Imperial Coll London, NHLI, London, England
[11] Kyoto Univ Hosp, Dept Cardiovasc Med, Kyoto, Japan
关键词
bioresorbable scaffolds; drug-eluting stent; optical coherence tomography; quantitative coronary angiography; OPTICAL COHERENCE TOMOGRAPHY; ENDOTHELIAL SHEAR-STRESS; ARTERY-DISEASE; FOLLOW-UP; INTRAVASCULAR ULTRASOUND; VASCULAR SCAFFOLDS; ABSORB JAPAN; II TRIAL; IMPLANTATION; MICROENVIRONMENT;
D O I
10.4244/EIJ-D-17-00070
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims: Immediately after stent/scaffold implantation, quantitative coronary angiography (QCA) in comparison to optical coherence tomography (OCT) more severely underestimates the lumen diameter (LD) in Absorb than in XIENCE. This OCT-QCA discrepancy has not been evaluated at long-term follow-up. The present study aimed to assess the accuracy of QCA with reference to OCT in Absorb as compared to XIENCE. Methods and results: We assessed two-year QCA and OCT in the ABSORB Japan randomised trial (Absorb n=87, XIENCE n=44). The accuracy of QCA parameters was assessed with reference to OCT measurements. OCT-QCA luminal dimensions were compared in matched cross-sections at both edges of the scaffolds (n=127) and stents (n=78). OCT-QCA late lumen loss (LLL) was also assessed using the Bland-Altman method. The systematic error of LD on QCA in Absorb was -0.092 mm (relative difference -3.3%) with a random error of 0.473 mm, whereas in XIENCE the systematic error was -0.018 mm (-0.5%) with a random error of 0.477 mm. These OCT-QCA discrepancies did not differ between Absorb and XIENCE (p=0.275) at two-year follow-up. QCA tended to underestimate LLL more in Absorb than in XIENCE (QCA-LLL minus OCT-LLL: -0.180 +/- 0.308 mm vs. -0.058 +/- 0.322 mm, p=0.058) at two-year follow-up, although this comparison was not statistically powered. Conclusions: The two-year dimensional measurements on QCA had minor and insignificant systematic errors between both devices. A discrepancy between QCA-LLL and OCT-LLL would raise a question as to whether this parameter is appropriate for the comparative assessment of device performance.
引用
收藏
页码:585 / 594
页数:10
相关论文
共 28 条
  • [1] Is quantitative coronary angiography reliable in assessing the lumen gain after treatment with the everolimus-eluting bioresorbable polylactide scaffold?
    Sotomi, Yohei
    Onuma, Yoshinobu
    Suwannasom, Pannipa
    Tateishi, Hiroki
    Tenekecioglu, Erhan
    Zeng, Yaping
    Cavalcante, Rafael
    Jonker, Hans
    Dijkstra, Jouke
    Foin, Nicolas
    Koon, Jaryl Ng Chen
    Collet, Carlos
    de Winter, Robbert J.
    Wykrzykowska, Joanna J.
    Stone, Gregg W.
    Popma, Jeffrey J.
    Kozuma, Ken
    Tanabe, Kengo
    Serruys, Patrick W.
    Kimura, Takeshi
    EUROINTERVENTION, 2016, 12 (08) : E998 - E1008
  • [2] Fate of post-procedural malapposition of everolimus-eluting polymeric bioresorbable scaffold and everolimus-eluting cobalt chromium metallic stent in human coronary arteries: sequential assessment with optical coherence tomography in ABSORB Japan trial
    Sotomi, Yohei
    Onuma, Yoshinobu
    Dijkstra, Jouke
    Miyazaki, Yosuke
    Kozuma, Ken
    Tanabe, Kengo
    Popma, Jeffrey J.
    de Winter, Robbert J.
    Serruys, Patrick W.
    Kimura, Takeshi
    EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2018, 19 (01) : 59 - 66
  • [3] Everolimus-eluting bioresorbable scaffold versus everolimus-eluting metallic stent in primary percutaneous coronary intervention of ST-segment elevation myocardial infarction: a randomized controlled trial
    Eriksen, Erlend
    Neghabat, Omeed
    Saeed, Sahrai
    Herstad, Jon
    Nordrehaug, Jan Erik
    Tuseth, Vegard
    Holm, Niels Ramsing
    Holck, Emil Nielsen
    Sejr-Hansen, Martin
    Maule, Camilla Fox
    Barkholt, Trine Orhoj
    Andreasen, Lene Nyhus
    Christiansen, Evald Hoj
    Bleie, Oyvind
    CORONARY ARTERY DISEASE, 2023, 34 (01) : 1 - 10
  • [4] Comparison of the everolimus-eluting bioresorbable vascular scaffold versus the everolimus-eluting metallic stent in real-world patients with ST-segment elevation myocardial infarction
    Desperak, Piotr
    Hawranek, Michal
    Chodor, Piotr A.
    Swiatkowski, Andrzej
    Kowalczyk, Jacek
    Lekston, Andrzej
    Gasior, Mariusz
    POSTEPY W KARDIOLOGII INTERWENCYJNEJ, 2020, 16 (01): : 49 - 57
  • [5] Long-Term Safety of an Everolimus-Eluting Bioresorbable Vascular Scaffold and the Cobalt-Chromium XIENCE V Stent in a Porcine Coronary Artery Model
    Otsuka, Fumiyuki
    Pacheco, Erica
    Perkins, Laura E. L.
    Lane, Jennifer P.
    Wang, Qing
    Kamberi, Marika
    Frie, Michael
    Wang, Jin
    Sakakura, Kenichi
    Yahagi, Kazuyuki
    Ladich, Elena
    Rapoza, Richard J.
    Kolodgie, Frank D.
    Virmani, Renu
    CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2014, 7 (03) : 330 - 342
  • [6] Randomized Comparison Between Everolimus-Eluting Bioresorbable Scaffold and Metallic Stent Multimodality Imaging Through 3 Years
    Onuma, Yoshinobu
    Honda, Yasuhiro
    Asano, Taku
    Shiomi, Hiroki
    Kozuma, Ken
    Ozaki, Yukio
    Namiki, Atsuo
    Yasuda, Satoshi
    Ueno, Takafumi
    Ando, Kenji
    Furuya, Jungo
    Hanaoka, Keiichi Igarashi
    Tanabe, Kengo
    Okada, Kozo
    Kitahara, Hideki
    Ono, Masafumi
    Kusano, Hajime
    Rapoza, Richard
    Simonton, Charles
    Popma, Jeffrey J.
    Stone, Gregg W.
    Fitzgerald, Peter J.
    Serruys, Patrick W.
    Kimura, Takeshi
    JACC-CARDIOVASCULAR INTERVENTIONS, 2020, 13 (01) : 116 - 127
  • [7] Randomized comparison of acute stent malapposition between platinum-chromium versus cobalt-chromium everolimus-eluting stents
    Kim, Byeong-Keuk
    Shin, Dong-Ho
    Kim, Jung-Sun
    Ko, Young-Guk
    Choi, Donghoon
    Jang, Yangsoo
    Hong, Myeong-Ki
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2015, 31 (02): : 269 - 277
  • [8] Comparison of In Vivo Acute Stent Recoil Between the Bioresorbable Everolimus-Eluting Coronary Scaffolds (Revision 1.0 and 1.1) and the Metallic Everolimus-Eluting Stent
    Onuma, Yoshinobu
    Serruys, Patrick W.
    Gomez, Josep
    de Bruyne, Bernard
    Dudek, Dariusz
    Thuesen, Leif
    Smits, Peter
    Chevalier, Bernard
    McClean, Dougal
    Koolen, Jacques
    Windecker, Stephan
    Whitbourn, Robert
    Meredith, Ian
    Garcia-Garcia, Hector
    Ormiston, John A.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2011, 78 (01) : 3 - 12
  • [9] Sirolimus-eluting iron bioresorbable scaffold versus cobalt-chromium everolimus-eluting stents in patients with coronary artery disease: Rationale and design of the IRONMAN-II trial
    Song, Lei
    Guan, Changdong
    Yu, Mengyue
    Sun, Zhongwei
    Fu, Guosheng
    He, Yong
    Jia, Shaobin
    Chen, Jiyan
    Qi, Feng
    Bai, Jie
    Li, Wei
    Ge, Junbo
    Han, Yaling
    Gao, Runlin
    AMERICAN HEART JOURNAL, 2024, 275 : 53 - 61
  • [10] Performance of bioresorbable vascular scaffolds versus cobalt-chromium everolimus-eluting stent in patients with ST-elevation myocardial infarction undergoing primary percutaneous coronary intervention: a review of currently available clinical data
    Buccheri, Dario
    Piraino, Davide
    Chirco, Paola R.
    Cortese, Bernardo
    MINERVA CARDIOANGIOLOGICA, 2016, 64 (01): : 74 - 83