Optical feedback signal for ultrashort laser-pulse ablation of tissue

被引:49
作者
Kim, BM [1 ]
Feit, MD [1 ]
Rubenchik, AM [1 ]
Mammini, BM [1 ]
Da Silva, LB [1 ]
机构
[1] Univ Calif Lawrence Livermore Natl Lab, Livermore, CA 94550 USA
关键词
ultrashort pulse laser; tissue ablation; plasma luminescence; tissue fluorescence; optical feedback system;
D O I
10.1016/S0169-4332(97)00756-3
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
An optical feedback system for controlled precise tissue ablation is discussed. Our setup includes an ultrashort pulse laser (USPL), and a diagnostic system utilizing analysis of either tissue fluorescence or plasma emission luminescence. Current research is focused on discriminating hard and soft tissues such as bone and spinal cord during spinal surgery using either technique. Our experimental observations exhibit considerable spectroscopic contrast between hard and soft tissue, and both techniques offer promise for a practical diagnostic system. (C) 1998 Elsevier Science B.V.
引用
收藏
页码:857 / 862
页数:6
相关论文
共 20 条
[1]   FEMTOSECOND LASER TISSUE INTERACTIONS - RETINAL INJURY STUDIES [J].
BIRNGRUBER, R ;
PULIAFITO, CA ;
GAWANDE, A ;
LIN, WZ ;
SCHOENLEIN, RW ;
FUJIMOTO, JG .
IEEE JOURNAL OF QUANTUM ELECTRONICS, 1987, 23 (10) :1836-1844
[2]   Comparison of soft and hard tissue ablation with sub-ps and ns pulse lasers [J].
DaSilva, LB ;
Stuart, BC ;
Celliers, PM ;
Chang, TD ;
Feit, MD ;
Glinsky, ME ;
Heredia, NJ ;
Herman, S ;
Lane, SM ;
London, RA ;
Matthews, DL ;
Neev, J ;
Perry, MD ;
Rubenchik, AM .
LASER-TISSUE INTERACTION VII, PROCEEDINGS OF, 1996, 2681 :196-200
[3]   DETECTION OF CALCIFIED ATHEROSCLEROTIC PLAQUE BY LASER-INDUCED PLASMA EMISSION [J].
DECKELBAUM, LI ;
SCOTT, JJ ;
STETZ, ML ;
OBRIEN, KM ;
BAKER, G .
LASERS IN SURGERY AND MEDICINE, 1992, 12 (01) :18-24
[4]   Physical characterization of ultrashort laser pulse drilling of biological tissue [J].
Feit, MD ;
Rubenchik, AM ;
Kim, BM ;
da Silva, LB ;
Perry, MD .
APPLIED SURFACE SCIENCE, 1998, 127 :869-874
[5]   DESIGN AND EVALUATION OF A FIBEROPTIC FLUORESCENCE GUIDED LASER RECANALIZATION SYSTEM [J].
GARRAND, TJ ;
STETZ, ML ;
OBRIEN, KM ;
GINDI, GR ;
SUMPIO, BE ;
DECKELBAUM, LI .
LASERS IN SURGERY AND MEDICINE, 1991, 11 (02) :106-116
[6]   Shock wave and cavitation bubble dynamics during photodisruption in ocular media and their dependence on the pulse duration [J].
Juhasz, T ;
Kastis, G ;
Suarez, C ;
Turi, L ;
Bor, Z ;
Bron, WE .
LASER-TISSUE INTERACTION VII, PROCEEDINGS OF, 1996, 2681 :428-436
[7]   DYNAMICS OF SHOCK-WAVES AND CAVITATION BUBBLES GENERATED BY PICOSECOND LASER-PULSES IN CORNEAL TISSUE AND WATER [J].
JUHASZ, T ;
HU, XH ;
TURI, L ;
BOR, Z .
LASERS IN SURGERY AND MEDICINE, 1994, 15 (01) :91-98
[8]  
Juhasz T, 1996, LASER SURG MED, V19, P23, DOI 10.1002/(SICI)1096-9101(1996)19:1<23::AID-LSM4>3.0.CO
[9]  
2-S
[10]  