Development of an optimized sorbent for direct HPTLC-FTIR on-line coupling

被引:0
|
作者
Bauer, GK
Pfeifer, AM
Hauck, HE
Kovar, KA
机构
[1] Univ Tubingen, Inst Pharmaceut, D-72076 Tubingen, Germany
[2] Merck KFaA, D-64271 Darmstadt, Germany
关键词
HPTLC-FTIR on-line coupling; sorbent; magnesium tungstate; separation number; DRIFT;
D O I
暂无
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
By use of a combination of silica gel 60 and a weak infrared-active, reflection-enhancing material, the quality of DRIFT (diffuse reflectance infrared Fourier transform spectroscopy) spectra was improved and the signal-to-noise ratio of adsorbed substances increased. Of the reflection-enhancers tested, magnesium tungstate proved the most suitable; the optimum proportion was 50%. For this type of layer the signal-to-noise ratios for caffeine, paracetamol, and phenazone were increased by factors of 3.4, 3.1, and 2.3, respectively, compared with those obtained on pure silica gel 60. Use of material of small mean particle-diameter and narrow particle-size distribution provided an almost optimum diffuse reflecting surface. addition of strongly reflecting metallic powders to the silica gel had the effect of increasing diffuse Fresnel reflection in particular; this did not, however, contain desired spectral information. The same effect was also achieved with reflecting sorbent supports. In contrast with aluminum-coated glass plates, normal glass plates absorb most of the LR radiation, a small proportion only being reflected. When aluminum-coated glass plates mere used as supports small fluctuations in layer thickness resulted in artefact peaks in the chromatograms, Layer thickness sensitivity was less for normal glass plates. A layer thickness of 100 mu m for a 50:50 (m/m) mixture of silica gel 60 and magnesium tungstate on a normal glass plate proved to be the most suitable combination. The chromatographic, analytical, and spectroscopic performance of the optimized sorbent layer were investigated using separation numbers, detection limits, and the quality of the DRIFT spectra of selected substances. addition of 50% magnesium tungstate resulted in sorbent layers with separation performance practically identical with that of silica gel 60 F-254s, even though the retention properties were different, By use of this optimized sorbent layer, detection limits were reduced by a factor of 3.7 for caffeine and 2.3 for both paracetamol and phenazone. In addition, the evaluable IR range was extended by approximately 100 wavenumbers to approximately 1270 cm(-1) in the 'fingerprint' range. This enabled the detection of mo additional caffeine bands which, if a conventional silica gel layer had been used, would hare been superimposed by the wide interference bands occurring at approximately 1340 cm(-1).
引用
收藏
页码:84 / 89
页数:6
相关论文
共 47 条
  • [21] Fully On-line TLC/HPTLC with Diode-Array Detection and Continuous Development. Part 1: Description of the Method and Basic Possibilities
    Szabolcs Nyiredy
    JPC – Journal of Planar Chromatography – Modern TLC, 2002, 15 : 454 - 457
  • [22] Fully on-line TLC/HPTLC with diode-array detection and continuous development. part 1: Description of the method and basic possibilities
    Nyiredy, S
    JPC-JOURNAL OF PLANAR CHROMATOGRAPHY-MODERN TLC, 2002, 15 (06) : 454 - 457
  • [23] Mixed-mode column allows simple direct coupling with immobilized enzymatic reactor for on-line protein digestion
    Vosahlova-Kadlecova, Zuzana
    Gilar, Martin
    Molnarova, Katarina
    Kozlik, Petr
    Kalikova, Kveta
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2023, 1228
  • [24] ATR-FTIR sensor development for continuous on-line monitoring of chlorinated aliphatic hydrocarbons in a fixed-bed bioreactor
    Acha, Victor
    Meurens, Marc
    Naveau, Henry
    Agathos, Spiros N.
    Biotechnology and Bioengineering, 2000, 68 (05) : 473 - 487
  • [25] In-situ surface reflective FTIR and on-line transmission spectroscopy of direct methanol fuel cell anode surfaces and exhaust at 50°C
    Bo, A
    Sanicharane, S
    Liu, RX
    Sompalli, B
    Hou, GY
    Fan, QB
    Gurau, B
    Smotkin, ES
    SPECTROSCOPIC TOOLS FOR THE ANALYSIS OF ELECTROCHEMICAL SYSTEMS, 2002, 99 (15): : 94 - 110
  • [26] Cigarette filter as sorbent for on-line coupling of solid-phase extraction to high-performance liquid chromatography for determination of polycyclic aromatic hydrocarbons in water
    Liang, HD
    Han, DM
    Yan, XP
    JOURNAL OF CHROMATOGRAPHY A, 2006, 1103 (01) : 9 - 14
  • [27] On-line microdialysis of proteins with high-salt buffers for direct coupling of electrospray ionization mass spectrometry and liquid chromatography
    Canarelli, S
    Fisch, I
    Freitag, R
    JOURNAL OF CHROMATOGRAPHY A, 2002, 948 (1-2) : 139 - 149
  • [28] HPLC-NMR on-line coupling including the ROESY technique:: Direct characterization of naphthylisoquinoline alkaloids in crude plant extracts
    Bringmann, G
    Günther, C
    Schlauer, J
    Rückert, M
    ANALYTICAL CHEMISTRY, 1998, 70 (14) : 2805 - 2811
  • [29] On-line coupling of immobilized cytochrome P450 microreactor and capillary electrophoresis: A promising tool for drug development
    Schejbal, Jan
    Reminek, Roman
    Zeman, Lukas
    Madr, Ales
    Glatz, Zdenek
    JOURNAL OF CHROMATOGRAPHY A, 2016, 1437 : 234 - 240
  • [30] Multiwalled carbon nanotubes as sorbent for on-line coupling of solid-phase extraction to high-performance liquid chromatography for simultaneous determination of 10 sulfonamides in eggs and pork
    Fang, Guo-Zhen
    He, Jin-Xing
    Wang, Shuo
    JOURNAL OF CHROMATOGRAPHY A, 2006, 1127 (1-2) : 12 - 17