Mapping 3D Strains with Ultrasound Speckle Tracking: Method Validation and Initial Results in Porcine Scleral Inflation

被引:22
作者
Perez, Benjamin Cruz [1 ]
Pavlatos, Elias [1 ]
Morris, Hugh J. [1 ]
Chen, Hong [1 ]
Pan, Xueliang [2 ]
Hart, Richard T. [1 ]
Liu, Jun [1 ,3 ]
机构
[1] Ohio State Univ, Dept Biomed Engn, 270 Bevis Hall,1080 Carmack Rd, Columbus, OH 43210 USA
[2] Ohio State Univ, Ctr Biostat, Columbus, OH 43210 USA
[3] Ohio State Univ, Dept Ophthalmol, Columbus, OH 43210 USA
关键词
Scleral biomechanics; 3D strains; Ultrasound speckle tracking; Inflation testing; Peripapillary sclera; OPTIC-NERVE HEAD; POSTERIOR SCLERA; VISCOELASTIC BEHAVIOR; ELASTICITY MICROSCOPE; GLAUCOMA; DISPLACEMENT; BIOMECHANICS; RESOLUTION; RESPONSES;
D O I
10.1007/s10439-015-1506-1
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This study aimed to develop and validate a high frequency ultrasound method for measuring distributive, 3D strains in the sclera during elevations of intraocular pressure. A 3D cross-correlation based speckle-tracking algorithm was implemented to compute the 3D displacement vector and strain tensor at each tracking point. Simulated ultrasound radiofrequency data from a sclera-like structure at undeformed and deformed states with known strains were used to evaluate the accuracy and signal-to-noise ratio (SNR) of strain estimation. An experimental high frequency ultrasound (55 MHz) system was built to acquire 3D scans of porcine eyes inflated from 15 to 17 and then 19 mmHg. Simulations confirmed good strain estimation accuracy and SNR (e.g., the axial strains had less than 4.5% error with SNRs greater than 16.5 for strains from 0.005 to 0.05). Experimental data in porcine eyes showed increasing tensile, compressive, and shear strains in the posterior sclera during inflation, with a volume ratio close to one suggesting near-incompressibility. This study established the feasibility of using high frequency ultrasound speckle tracking for measuring 3D tissue strains and its potential to characterize physiological deformations in the posterior eye.
引用
收藏
页码:2302 / 2312
页数:11
相关论文
共 33 条
[21]   Dynamic testing of regional viscoelastic behavior of canine sclera [J].
Palko, Joel R. ;
Pan, Xueliang ;
Liu, Jun .
EXPERIMENTAL EYE RESEARCH, 2011, 93 (06) :825-832
[22]   Torsion of the Optic Nerve Head Is a Prominent Feature of Normal-Tension Glaucoma [J].
Park, Hae-Young L. ;
Lee, Kee-Il ;
Lee, Kook ;
Shin, Hye Young ;
Park, Chan Kee .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (01) :156-163
[23]   Biaxial mechanical testing of posterior sclera using high-resolution ultrasound speckle tracking for strain measurements [J].
Perez, Benjamin Cruz ;
Tang, Junhua ;
Morris, Hugh J. ;
Palko, Joel R. ;
Pan, Xueliang ;
Hart, Richard T. ;
Liu, Jun .
JOURNAL OF BIOMECHANICS, 2014, 47 (05) :1151-1156
[24]   Quantitative Mapping of Collagen Fiber Orientation in Non-glaucoma and Glaucoma Posterior Human Sclerae [J].
Pijanka, Jacek K. ;
Coudrillier, Baptiste ;
Ziegler, Kimberly ;
Sorensen, Thomas ;
Meek, Keith M. ;
Nguyen, Thao D. ;
Quigley, Harry A. ;
Boote, Craig .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2012, 53 (09) :5258-5270
[25]   MEDICAL PROGRESS - OPEN-ANGLE GLAUCOMA [J].
QUIGLEY, HA .
NEW ENGLAND JOURNAL OF MEDICINE, 1993, 328 (15) :1097-1106
[26]   Structural Factors That Mediate Scleral Stiffness [J].
Schultz, David S. ;
Lotz, Jeffrey C. ;
Lee, Shira M. ;
Trinidad, Monique L. ;
Stewart, Jay M. .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2008, 49 (10) :4232-4236
[27]   Factors influencing optic nerve head biomechanics [J].
Sigal, IA ;
Flanagan, JG ;
Ethier, CR .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46 (11) :4189-4199
[28]   THEORETICAL-ANALYSIS AND VERIFICATION OF ULTRASOUND DISPLACEMENT AND STRAIN IMAGING [J].
SKOVORODA, AR ;
EMELIANOV, SY ;
LUBINSKI, MA ;
SARVAZYAN, AP ;
ODONNELL, M .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1994, 41 (03) :302-313
[29]   Trade-offs between the axial resolution and the signal-to-noise ratio in elastography [J].
Srinivasan, S ;
Righetti, R ;
Ophir, J .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2003, 29 (06) :847-866
[30]   Ultrasonic Measurement of Scleral Cross-Sectional Strains During Elevations of Intraocular Pressure: Method Validation and Initial Results in Posterior Porcine Sclera [J].
Tang, Junhua ;
Liu, Jun .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2012, 134 (09)