Bilateral implantation of the Acri.LISA bifocal intraocular lens in myopic eyes

被引:14
|
作者
Fernandez-Vega, Luis [1 ,2 ]
Madrid-Costa, David [1 ,3 ]
Alfonso, Jose F. [1 ,2 ]
Poo-Lopez, Arancha [1 ]
Montes-Mico, Robert [4 ]
机构
[1] Inst Oftalmol Fernandez Vega, Oviedo 33012, Spain
[2] Univ Oviedo, Sch Med, Dept Surg, Oviedo, Spain
[3] Univ Europea Madrid, Opt & Optometry Dept, Madrid, Spain
[4] Univ Valencia, Fac Phys, Dept Opt, E-46003 Valencia, Spain
关键词
Acri.LISA; Multifocal IOL; Myopia; Visual acuity; RETINAL-DETACHMENT; CONTRAST SENSITIVITY; VISUAL PERFORMANCE; DISTANCE; QUALITY; EXTRACTION; RISK;
D O I
10.1177/112067211002000111
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. To asses visual quality after bilateral implantation of the Acri.LISA 366D intraocular lens (IOL) (Carl Zeiss Meditec) in patients with high and low-moderate myopia. METHODS. A total of 304 eyes of 152 patients had bilateral implantation of the Acri.LISA 366D IOL. The patients were divided into 2 groups: low-moderate myopia (IOL power from 15 to 20.5 D) and high myopia (IOL power from 0 to 14.5 D). Monocular and binocular best-corrected distance visual acuity (BCVA) and best distance-corrected near visual acuity (BCNVA), binocular best distance-corrected intermediate visual acuity (BCIVA), and distance contrast sensitivity (CS) under photopic (85 cd/m(2)) and mesopic (5 cd/m2) conditions were determined. RESULTS. At the 6-month postoperative visit, there were no statistically significant differences in monocular and binocular BCVA (p=0.13 and p=0.22, respectively). Monocular and binocular BCNVA was comparable between the groups (p=0.26 and p=0.09, respectively). The mean binocular BCIVA changed significantly as a function of the distance of the test (p<0.01) in both groups, and there were no statistically significant differences between groups at any distance. Monocular and binocular CS under photopic and mesopic conditions was similar between both groups (p>0.01). CONCLUSIONS. Bilateral implantation of the Acri.LISA 366D in high myopic eyes provides a satisfactory full range of vision comparable to that obtained in low-moderate myopic eyes. (Eur J Ophthalmol 2010; 20: 83-9)
引用
收藏
页码:83 / 89
页数:7
相关论文
共 50 条
  • [1] Refractive lens exchange with Acri.LISA bifocal intraocular lens implantation
    Alfonso, Jose F.
    Fernandez-Vega, Luis
    Baamonde, Begona
    Orti, Susana
    Montes-Mico, Robert
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2011, 21 (02) : 125 - 131
  • [2] Refractive lens exchange with the Acri.Twin asymmetric diffractive bifocal intraocular lens system
    Alfonso, Jose F.
    Fernandez-Vega, Luis
    Orti, Susana
    Montes-Mico, Robert
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2010, 20 (03) : 509 - 516
  • [3] Contrast Sensitivity Comparison Between AcrySof ReSTOR and Acri.LISA Aspheric Intraocular Lenses
    Alfonso, Jose F.
    Puchades, Cristina
    Fernandez-Vega, Luis
    Merayo, Carmen
    Montes-Mico, Robert
    JOURNAL OF REFRACTIVE SURGERY, 2010, 26 (07) : 471 - 477
  • [4] Visual and Refractive Outcomes in Hyperopic Pseudophakic Patients Implanted with the Acri.LISA 366D Multifocal Intraocular Lens
    Fernandez-Vega, Luis
    Alfonso, Jose F.
    Baamonde, Begona
    Madrid-Costa, David
    Montes-Mico, Robert
    Lozano, Javier
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2009, 148 (02) : 214 - 220
  • [5] Refractive lens exchange with distance-dominant diffractive bifocal intraocular lens implantation
    Alfonso, Jose F.
    Fernandez-Vega, Luis
    Orti, Susana
    Montes-Mico, Robert
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2010, 248 (10) : 1507 - 1514
  • [6] Retinal detachment after phakic intraocular lens implantation in severe myopic eyes
    Jiang, Tingting
    Chang, Qing
    Wang, Xiaoying
    Huang, Xin
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2012, 250 (12) : 1725 - 1730
  • [7] Retinal detachment after phakic intraocular lens implantation in severe myopic eyes
    Tingting Jiang
    Qing Chang
    Xiaoying Wang
    Xin Huang
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2012, 250 : 1725 - 1730
  • [8] Visual function after implantation of an aspheric bifocal intraocular lens
    Alfonso, Jose F.
    Fernandez-Vega, Luis
    Amhaz, Hussein
    Montes-Mico, Robert
    Valcarcel, Beatriz
    Ferrer-Blasco, Teresa
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (05) : 885 - 892
  • [9] Bilateral Implantation of a Single-Piece Bifocal Diffractive Intraocular Lens in Presbyopic Patients: A Prospective Case Series
    Chang, John S. M.
    ASIA-PACIFIC JOURNAL OF OPHTHALMOLOGY, 2019, 8 (01): : 12 - 21
  • [10] Long-term objective and subjective outcomes following bilateral implantation of diffractive bifocal or trifocal intraocular lenses
    Vargas, Veronica
    Alio, Jorge L.
    Oliveira, Renan F.
    Renna, Antonio
    Yebana, Pilar
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2021, 31 (03) : 1014 - 1020