Reliability, Concurrent Validity, and Minimal Detectable Change for iPhone Goniometer App in Assessing Knee Range of Motion

被引:44
作者
Mehta, Saurabh P. [1 ,2 ]
Barker, Katherine [1 ]
Bowman, Brett [3 ]
Galloway, Heather [4 ]
Oliashirazi, Nicole [2 ]
Oliashirazi, Ali [2 ]
机构
[1] Marshall Univ, Sch Phys Therapy, 284 5th Ave, Huntington, WV 25702 USA
[2] Marshall Univ, Joan C Edwards Sch Med, Dept Orthoped Surg, Huntington, WV USA
[3] Southern Ohio Med Ctr, SOMC LIFE Ctr, Portsmouth, OH USA
[4] Elk Valley Phys Therapy, Dept Phys Therapy, Elkview, WV USA
关键词
goniometer; reliability; knee range of motion; PAIN INTENSITY MEASUREMENT; UNIVERSAL GONIOMETER; ARTHROPLASTY; AGREEMENT; FLEXION; SCALES; ANGLE;
D O I
10.1055/s-0036-1593877
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Much of the published works assessing the reliability of smartphone goniometer apps (SG) have poor generalizability since the reliability was assessed in healthy subjects. No research has established the values for standard error of measurement (SEM) or minimal detectable change (MDC) which have greater clinical utility to contextualize the range of motion (ROM) assessed using the SG. This research examined the test-retest reproducibility, concurrent validity, SEM, and MDC values for the iPhone goniometer app (i-Goni; June Software Inc., v.1.1, San Francisco, CA) in assessing knee ROM in patients with knee osteoarthritis or those after total knee replacement. A total of 60 participants underwent data collection which included the assessment of active knee ROM using the i-Goni and the universal goniometer (UG; EZ Read Jamar Goniometer, Patterson Medical, Warrenville, IL), knee muscle strength, and assessment of pain and lower extremity disability using quadruple numeric pain rating scale (Q-NPRS) and lower extremity functional scale (LEFS), respectively. Intraclass correlation coefficients (ICCs) were calculated to assess the reproducibility of the knee ROM assessed using the i-Goni and UG. Bland and Altman technique examined the agreement between these knee ROM. The SEM and MDC values were calculated for i-Goni assessed knee ROM to characterize the error in a single score and the index of true change, respectively. Pearson correlation coefficient examined concurrent relationships between the i-Goni and other measures. The ICC values for the knee flexion/extension ROM were superior for i-Goni (0.97/0.94) compared with the UG (0.95/0.87). The SEM values were smaller for i-Goni assessed knee flexion/extension (2.72/1.18 degrees) compared with UG assessed knee flexion/extension (3.41/1.62 degrees). Similarly, the MDC values were smaller for both these ROM for the i-Goni (6.3 and 2.72 degrees) suggesting smaller change required to infer true change in knee ROM. The i-Goni assessed knee ROM showed expected concurrent relationships with UG, knee muscle strength, Q-NPRS, and the LEFS. In conclusion, the i-Goni demonstrated superior reproducibility with smaller measurement error compared with UG in assessing knee ROM in the recruited cohort. Future research can expand the inquiry for assessing the reliability of the i-Goni to other joints.
引用
收藏
页码:577 / 584
页数:8
相关论文
共 34 条
[1]   THE RELIABILITY AND VALIDITY OF HANDHELD DYNAMOMETRY FOR THE MEASUREMENT OF LOWER-EXTREMITY MUSCLE STRENGTH IN OLDER ADULTS [J].
Arnold, Cathy M. ;
Warkentin, Kathryn D. ;
Chilibeck, Phimp D. ;
Magnus, Charlene R. A. .
JOURNAL OF STRENGTH AND CONDITIONING RESEARCH, 2010, 24 (03) :815-824
[2]  
Bennett D., 2009, Orthopedics, V32
[3]   Agreement between methods of measurement with multiple observations per individual [J].
Bland, J. Martin ;
Altman, Douglas G. .
JOURNAL OF BIOPHARMACEUTICAL STATISTICS, 2007, 17 (04) :571-582
[4]  
Bland JM, 1999, STAT METHODS MED RES, V8, P135, DOI 10.1177/096228029900800204
[5]  
Brosseau L, 1997, Physiother Res Int, V2, P150
[6]   Intra- and intertester reliability and criterion validity of the parallelogram and universal goniometers for measuring maximum active knee flexion and extension of patients with knee restrictions [J].
Brosseau, L ;
Balmer, S ;
Tousignant, M ;
O'Sullivan, JP ;
Goudreault, C ;
Goudreault, M ;
Gringras, S .
ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2001, 82 (03) :396-402
[7]   COMPARISON OF THE RELIABILITY OF THE ORTHORANGER AND THE STANDARD GONIOMETER FOR ASSESSING ACTIVE LOWER-EXTREMITY RANGE OF MOTION [J].
CLAPPER, MP ;
WOLF, SL .
PHYSICAL THERAPY, 1988, 68 (02) :214-218
[8]   INTRA AND INTER EXAMINER RELIABILITY AND MEASUREMENT ERROR OF GONIOMETER AND DIGITAL INCLINOMETER USE [J].
dos Santos, Carolline Maciel ;
Ferreira, Gilver ;
Malacco, Priscilla Lorenzatto ;
Sabino, George Schayer ;
de Souza Moraes, Geraldo Fabiano ;
Felicio, Diogo Carvalho .
REVISTA BRASILEIRA DE MEDICINA DO ESPORTE, 2012, 18 (01) :38-41
[9]  
Fitzpatrick R, 1998, Health Technol Assess, V2, P1
[10]  
Fitzpatrick R, 1998, Health Technol Assess, V2, pi