An Improved Control Strategy Using a PI-Resonant Controller for an Unbalanced Stand-Alone Doubly-Fed Induction Generator

被引:19
作者
Phan, Van-Tung [1 ]
Lee, Hong-Hee [1 ]
Chun, Tae-Won [1 ]
机构
[1] Univ Ulsan, Sch Elect Engn, Ulsan 680749, South Korea
关键词
Doubly-fed induction generator (DFIG); Resonant controller; Unbalanced stand-alone system; Wind energy; BACK PWM CONVERTERS; WIND; OPERATION; SYSTEMS;
D O I
10.6113/JPE.2010.10.2.194
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The main cause of degradation in an unbalanced stand-alone doubly-fed induction generator (DFIG) system is negative sequence components that exist in the generated stator voltages. To eliminate these components, a hybrid current controller composed of a proportional-integral controller and a resonant regulator is developed in this paper. The proposed controller is applied to the rotor-side converter of a DFIG system for the purpose of compensating the negative stator voltage sequences. The proposed current controller is implemented in a single positive rotating reference frame and therefore the controller can directly regulate both the positive and negative sequence components without the need for sequential decomposition of the measured rotor currents. In terms of compensation capability and accuracy, simulations and experimental results demonstrated the excellent performance of the proposed control method when compared to conventional vector control schemes.
引用
收藏
页码:194 / 202
页数:9
相关论文
共 15 条
[1]   Control of a doubly fed induction wind generator under unbalanced grid voltage conditions [J].
Brekken, Ted K. A. ;
Mohan, Ned .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2007, 22 (01) :129-135
[2]   Exact voltage unbalance assessment without phase measurements [J].
Ghijselen, JAL ;
Van den Bossche, APM .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2005, 20 (01) :519-520
[3]  
Kazmierkowski M., 2002, Control in power electronics selected problems
[4]   Multiple harmonics control for three-phase grid converter systems with the use of PI-RES current controller in a rotating frame [J].
Liserre, Marco ;
Teodorescu, Remus ;
Blaabjerg, Frede .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2006, 21 (03) :836-841
[5]   Doubly fed induction generator systems for wind turbines [J].
Müller, S ;
Deicke, M ;
De Doncker, RW .
IEEE INDUSTRY APPLICATIONS MAGAZINE, 2002, 8 (03) :26-33
[6]   A doubly fed induction generator using back-to-back PWM converters supplying an isolated load from a variable speed wind turbine [J].
Pena, R ;
Clare, JC ;
Asher, GM .
IEE PROCEEDINGS-ELECTRIC POWER APPLICATIONS, 1996, 143 (05) :380-387
[7]   Doubly fed induction generator using back-to-back PWM converters and its application to variable-speed wind-energy generation [J].
Pena, R ;
Clare, JC ;
Asher, GM .
IEE PROCEEDINGS-ELECTRIC POWER APPLICATIONS, 1996, 143 (03) :231-241
[8]  
PENA R, 2008, ELECT POWER SYST JUL
[9]  
Peña R, 2007, IEEE T ENERGY CONVER, V22, P544, DOI [10.1109/TEC.2007.895393, 10.1109/TEC.2006.895393]
[10]   Modeling and control of a wind turbine driven doubly fed induction generator [J].
Tapia, A ;
Tapia, G ;
Ostolaza, JX ;
Sáenz, JR .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2003, 18 (02) :194-204