Improvement of axial resolution for optical coherence tomography using a synthesized light source

被引:0
|
作者
Sato, M [1 ]
Wakaki, I [1 ]
Watanabe, Y [1 ]
Tanno, N [1 ]
机构
[1] Yamagata Univ, Yonezawa, Yamagata 9928510, Japan
来源
ROMOPTO 2003: SEVENTH CONFERENCE ON OPTICS | 2004年 / 5581卷
关键词
optical coherence tomography; synthesized light source; coherence length;
D O I
10.1117/12.583033
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We demonstrated that a synthesized light source (SLS) consisting of two low coherence light sources is capable of enhancing spatial resolution in optical coherence tomography (OCT). The axial resolution of OCT is given by the half of coherence length of the light source. We fabricated an SLS with a coherence length of 2.3 mum and the side lobe intensity of 29 % under the intensity ratio of LED 1: LED 2 = 1: 0.4 by combining two light sources, LED 1 with a central wavelength of 700 nm and spectral bandwidth of 100 rim, and LED 2 of 898 nm and 85 nm. The coherence length of 2.3 Eun is 56% of the shorter coherence length in two LED's, therefore the axial resolution is 1.2 mum.
引用
收藏
页码:662 / 669
页数:8
相关论文
共 50 条
  • [1] Axial resolution improvement by modulated deconvolution in Fourier domain optical coherence tomography
    Bousi, Evgenia
    Pitris, Costas
    JOURNAL OF BIOMEDICAL OPTICS, 2012, 17 (07)
  • [2] Fourier Domain Optical Coherence Tomography axial resolution improvement with modulated deconvolution
    Bousi, Evgenia
    Charalambous, Ismini
    Pitris, Costas
    OPTICAL COHERENCE TOMOGRAPHY AND COHERENCE TECHNIQUES V, 2011, 8091
  • [3] High resolution spectral-domain optical coherence tomography using a thermal light source
    Yu-Wei Qin
    Hong Zhao
    Zhong-Qin Zhuang
    Lu Zhang
    Optical and Quantum Electronics, 2012, 43 : 83 - 90
  • [4] Synthesized light source for optical coherence tomograph
    Jedrzejewska-Szczerska, M
    Hypszer, R
    Kosmowski, BB
    PHOTONICS APPLICATIONS IN ASTRONOMY, COMMUNICATIONS, INDUSTRY, AND HIGH-ENERGY PHYSICS EXPERIMENTS IV, 2006, 6159
  • [5] High resolution spectral-domain optical coherence tomography using a thermal light source
    Qin, Yu-Wei
    Zhao, Hong
    Zhuang, Zhong-Qin
    Zhang, Lu
    OPTICAL AND QUANTUM ELECTRONICS, 2012, 43 (6-10) : 83 - 90
  • [6] Ultra-high resolution spectral domain optical coherence tomography using supercontinuum light source
    Lim, Yiheng
    Yatagai, Toyohiko
    Otani, Yukitoshi
    OPTICAL REVIEW, 2016, 23 (02) : 180 - 186
  • [7] Ultrahigh resolution optical coherence tomography at two infrared wavelength regions using a single light source
    Spoeler, Felix
    Kray, Stefan
    Grychtol, Patrik
    Hermes, Barbara
    Bornemann, Joerg
    Foerst, Michael
    Kurz, Heinrich
    OPTICAL COHERENCE TOMOGRAPHY AND COHERENCE TECHNIQUES III, 2007, 6627
  • [8] Ultra-high resolution spectral domain optical coherence tomography using supercontinuum light source
    Yiheng Lim
    Toyohiko Yatagai
    Yukitoshi Otani
    Optical Review, 2016, 23 : 180 - 186
  • [9] Ultra-High Resolution Optical Coherence Tomography (OCT) Using a Halogen Lamp as the Light Source
    Masato Ohmi
    Masamitsu Haruna
    Optical Review, 2003, 10 : 478 - 481
  • [10] Axial resolution improvement by spectral data fusion in simultaneous dual-band optical coherence tomography
    Cimalla, Peter
    Gaertner, Maria
    Walther, Julia
    Koch, Edmund
    OPTICAL COHERENCE TOMOGRAPHY AND COHERENCE TECHNIQUES V, 2011, 8091