Suspended solids and nutrient retention in two constructed wetlands as determined from continuous data recorded with sensor

被引:9
作者
Koskiaho, Jari [1 ]
Puustinen, Markku [1 ]
机构
[1] Finnish Environm Inst, POB 140, FIN-00251 Helsinki, Finland
关键词
Constructed wetlands; Sensors; Turbidity; Nutrients; Event-driven retention; Non-point source; PHOSPHORUS CONCENTRATIONS; WATER; RUNOFF; EXPERIENCES; TRANSPORT; NITROGEN; REMOVAL; QUALITY; REDUCE;
D O I
10.1016/j.ecoleng.2019.04.006
中图分类号
Q14 [生态学(生物生态学)];
学科分类号
071012 ; 0713 ;
摘要
Constructed wetlands (CWs) are recognized as a useful method to reduce sediment and nutrient loading from arable land to surface waters. Automatic monitoring systems with continuously measuring sensors were utilized for several years to obtain accurate, up-to-date information of the retention performance of two differently dimensioned and located CWs in agricultural catchments in southern Finland. Here, results derived from the data recorded by the sensors measuring height, turbidity and nitrate-nitrogen (NO3-N) concentration of the water entering and exiting the Hovi (established in 1998) and Rantamo-Seitteli (est. in 2009) CWs are presented. Study periods ended in autumn 2014 and they lasted 7 years at Hovi and 4.5 years at Rantamo-Seitteli. Annual total suspended solids (TSS), total phosphorus (TP) and total nitrogen (TN) per cent retentions were much higher in the older, more generously dimensioned (CW-to-catchment area ratio 5%) Hovi CW (TSS 74%, TP 58% and TN 54% on average during 7 years) than in the newer, more scantly dimensioned (CW-to-catchment area ratio 1.3%) Rantamo-Seitteli CW (TSS 7%, TP 12% and TN 9% on average during 4.5 years). Moreover, the annual retentions of the Rantamo-Seitteli CW appeared to decrease with increasing runoff, while the retentions at Hovi were not affected by runoff fluctuations. In terms of TSS and TP retentions in the Hovi CW, they were in this study at similar levels to those observed shortly after the establishment of the CW. Meanwhile, the retention of dissolved nutrient fractions, i.e. NO3-N and dissolved reactive P (DRP, based on water sampling) at Hovi were clearly higher in this than in the previous study. The results confirm the importance of CW dimensioning and locating near the sources of loading, and refer to improved performance as CWs get older with increasing vegetation and biological activity. Our experiences of CW measurements with sensors have been positive. The information obtained with new technology has provided retention estimates that are more accurate than they would have been if they were derived from sparse grab sampling.
引用
收藏
页码:65 / 75
页数:11
相关论文
共 41 条
  • [1] Changing climate shifts timing of European floods
    Bloeschl, Guenter
    Hall, Julia
    Parajka, Juraj
    Perdigao, Rui A. P.
    Merz, Bruno
    Arheimer, Berit
    Aronica, Giuseppe T.
    Bilibashi, Ardian
    Bonacci, Ognjen
    Borga, Marco
    Canjevac, Ivan
    Castellarin, Attilio
    Chirico, Giovanni B.
    Claps, Pierluigi
    Fiala, Kaÿroly
    Frolova, Natalia
    Gorbachova, Liudmyla
    Gul, Ali
    Hannaford, Jamie
    Harrigan, Shaun
    Kireeva, Maria
    Kiss, Andrea
    Kjeldsen, Thomas R.
    Kohnova, Silvia
    Koskela, Jarkko J.
    Ledvinka, Ondrej
    Macdonald, Neil
    Mavrova-Guirguinova, Maria
    Mediero, Luis
    Merz, Ralf
    Molnar, Peter
    Montanari, Alberto
    Murphy, Conor
    Osuch, Marzena
    Ovcharuk, Valeryia
    Radevski, Ivan
    Rogger, Magdalena
    Salinas, Jose L.
    Sauquet, Eric
    Sraj, Mojca
    Szolgay, Jan
    Viglione, Alberto
    Volpi, Elena
    Wilson, Donna
    Zaimi, Klodian
    Zivkovic, Nenad
    [J]. SCIENCE, 2017, 357 (6351) : 588 - 590
  • [2] Braskerud B. C., 2001, THESIS
  • [3] Can constructed wetlands reduce the diffuse phosphorus loads to eutrophic water in cold temperate regions?
    Braskerud, BC
    Tonderski, KS
    Wedding, B
    Bakke, R
    Blankenberg, AGB
    Ulén, B
    Koskiaho, J
    [J]. JOURNAL OF ENVIRONMENTAL QUALITY, 2005, 34 (06) : 2145 - 2155
  • [4] Chadwick A. J., 1993, HYDRAULICS CIVIL ENV, P317
  • [5] Chave P., 2001, EU WATER FRAMEWORK D, P208
  • [6] Twenty-five years with OBS sensors: The good, the bad, and the ugly
    Downing, John
    [J]. CONTINENTAL SHELF RESEARCH, 2006, 26 (17-18) : 2299 - 2318
  • [7] Assessment of water protection targets for agricultural nutrient loading in Finland
    Granlund, K
    Räike, A
    Ekholm, P
    Rankinen, K
    Rekolainen, S
    [J]. JOURNAL OF HYDROLOGY, 2005, 304 (1-4) : 251 - 260
  • [8] Haarla L, 2011, POWER SYST, P61, DOI 10.1007/978-0-85729-145-5_5
  • [9] A practical tool for selecting cost-effective combinations of phosphorus loading mitigation measures in Finnish catchments
    Hjerppe, Turo
    Vaisanen, Sari
    [J]. INTERNATIONAL JOURNAL OF RIVER BASIN MANAGEMENT, 2015, 13 (03) : 363 - 376
  • [10] A National-Scale Nutrient Loading Model for Finnish Watersheds-VEMALA
    Huttunen, Inese
    Huttunen, Markus
    Piirainen, Vanamo
    Korppoo, Marie
    Lepisto, Ahti
    Raike, Antti
    Tattari, Sirkka
    Vehvilainen, Bertel
    [J]. ENVIRONMENTAL MODELING & ASSESSMENT, 2016, 21 (01) : 83 - 109