Regularity analysis of nocturnal oximetry recordings to assist in the diagnosis of sleep apnoea syndrome

被引:5
作者
Victor Marcos, J. [1 ]
Hornero, Roberto [1 ]
Nabney, Ian T. [2 ]
Alvarez, Daniel [1 ]
Gutierrez-Tobal, Gonzalo C. [1 ]
del Campo, Felix [3 ]
机构
[1] Univ Valladolid, Grp Ingn Biomed, ETS Ingn Telecomunicac, Paseo Belen 15, E-47011 Valladolid, Spain
[2] Aston Univ, Nonlinear & Complex Res Grp, Birmingham B4 7ET, W Midlands, England
[3] Hosp Univ Pio del Rio Hortega Valladolid, Dulzaina 2, Valladolid 47013, Spain
关键词
Oxygen saturation; Entropy rate; Approximate entropy; Sample entropy; Kernel entropy; Density estimation; PHYSIOLOGICAL TIME-SERIES; OVERNIGHT PULSE OXIMETRY; APPROXIMATE ENTROPY; SELECTION;
D O I
10.1016/j.medengphy.2015.11.010
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The relationship between sleep apnoea-hypopnoea syndrome (SAHS) severity and the regularity of nocturnal oxygen saturation (SaO(2)) recordings was analysed. Three different methods were proposed to quantify regularity: approximate entropy (AEn), sample entropy (SEn) and kernel entropy (KEn). A total of 240 subjects suspected of suffering from SAHS took part in the study. They were randomly divided into a training set (96 subjects) and a test set (144 subjects) for the adjustment and assessment of the proposed methods, respectively. According to the measurements provided by AEn, SEn and KEn, higher irregularity of oximetry signals is associated with SAHS-positive patients. Receiver operating characteristic (ROC) and Pearson correlation analyses showed that KEn was the most reliable predictor of SAHS. It provided an area under the ROC curve of 0.91 in two-class classification of subjects as SAHS-negative or SAHS-positive. Moreover, KEn measurements from oximetry data exhibited a linear dependence on the apnoea-hypopnoea index, as shown by a correlation coefficient of 0.87. Therefore, these measurements could be used for the development of simplified diagnostic techniques in order to reduce the demand for polysomnographies. Furthermore, KEn represents a convincing alternative to AEn and SEn for the diagnostic analysis of noisy biomedical signals. (C) 2015 IPEM. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:216 / 224
页数:9
相关论文
共 43 条
  • [1] Feature selection from nocturnal oximetry using genetic algorithms to assist in obstructive sleep apnoea diagnosis
    Alvarez, Daniel
    Hornero, Roberto
    Victor Marcos, J.
    del Campo, Felix
    [J]. MEDICAL ENGINEERING & PHYSICS, 2012, 34 (08) : 1049 - 1057
  • [2] Multivariate Analysis of Blood Oxygen Saturation Recordings in Obstructive Sleep Apnea Diagnosis
    Alvarez, Daniel
    Hornero, Roberto
    Marcos, J. Victor
    del Campo, Felix
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2010, 57 (12) : 2816 - 2824
  • [3] [Anonymous], 2002, NETLAB: Algorithms for Pattern rRcognition
  • [4] Rules for Scoring Respiratory Events in Sleep: Update of the 2007 AASM Manual for the Scoring of Sleep and Associated Events
    Berry, Richard B.
    Budhiraja, Rohit
    Gottlieb, Daniel J.
    Gozal, David
    Iber, Conrad
    Kapur, Vishesh K.
    Marcus, Carole L.
    Mehra, Reena
    Parthasarathy, Sairam
    Quan, Stuart F.
    Redline, Susan
    Strohl, Kingman P.
    Ward, Sally L. Davidson
    Tangredi, Michelle M.
    [J]. JOURNAL OF CLINICAL SLEEP MEDICINE, 2012, 8 (05): : 597 - 619
  • [5] Bishop CM, 1995, Neural Networks for Pattern Recognition
  • [6] Getting the most out of nocturnal pulse oximetry
    Bloch, KE
    [J]. CHEST, 2003, 124 (05) : 1628 - 1630
  • [7] Long-Term Tracking of a Patient's Health Condition Based on Pulse Rate Dynamics During Sleep
    Chen, Ying
    Chen, Wenxi
    [J]. ANNALS OF BIOMEDICAL ENGINEERING, 2011, 39 (12) : 2922 - 2934
  • [8] Nocturnal oximetry for the diagnosis of the sleep apnoea hypopnoea syndrome: a method to reduce the number of polysomnographies?
    Chiner, E
    Signes-Costa, J
    Arriero, JM
    Marco, J
    Fuentes, I
    Sergado, A
    [J]. THORAX, 1999, 54 (11) : 968 - 971
  • [9] Multiscale entropy analysis of biological signals
    Costa, M
    Goldberger, AL
    Peng, CK
    [J]. PHYSICAL REVIEW E, 2005, 71 (02):
  • [10] Oxygen saturation regularity analysis in the diagnosis of obstructive sleep apnea
    del Campo, Felix
    Hornero, Roberto
    Zamarron, Carlos
    Abasolo, Daniel E.
    Alvarez, Daniel