Analysis of axillary coverage during tangential radiation therapy to the breast

被引:121
作者
Reznik, J [1 ]
Cicchetti, MG [1 ]
DeGaspe, B [1 ]
Fitzgerald, TJ [1 ]
机构
[1] Univ Massachusetts, Mem Med Ctr, Dept Radiat Oncol, Worcester, MA 01655 USA
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2005年 / 61卷 / 01期
关键词
breast cancer; axillary lymph nodes; tangential fields; LYMPH-NODES; LEVEL-I; FIELDS; DISSECTION; CARCINOMA; SENTINEL; CANCER;
D O I
10.1016/j.ijrobp.2004.04.065
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To evaluate the percent of the prescribed radiation dose to the breast delivered to the axillary tissue and to evaluate the volume of the axilla receiving 95% of the prescribed dose with normal and with high tangential fields. Methods and Materials: Computed tomographic scan images with 5-mm sections were retrospectively analyzed for 35 patients who had undergone three-dimensional (3D) planning for whole-breast radiation. The axillary nodal region was identified and divided into Levels I to III and Rotter's nodes (RN). Digitally reconstructed radiographs were created, and two plans were developed: (a) the standard clinical opposed tangential irradiation fields and (b) the high-tangential irradiation fields. Axillary coverage was examined by use of dose-volume histograms (DVH), and the average coverage for the four nodal groups was obtained. Results: The data show that with the standard tangential irradiation fields, the average dose delivered to Levels I, II, III, and RN is 66% (standard deviation, or SD = 13%), 44% (SD = 18%), 31% (SD = 20%), and 70% (SD = 19%) of the prescribed dose, respectively. The coverage increases to 86 % (SD = 9 %), 71 % (SD = 19 %), 73 % (SD = 17%), and 94% (SD = 8%) of the prescribed dose, respectively, for Levels I, II, III, and RN when the high tangential irradiation fields are used. 51% of Level I, 26 % of Level II, and 15 % of Level III receive 95 % of the prescribed dose with normal tangents. The volume increases to 79%, 51%, and 49% of Levels I, II, and III, respectively, with high tangents. Conclusion: The tangential fields designed to treat only the breast do not adequately cover the axillary region and, therefore, cannot be relied upon for prophylactic therapy of the axilla. The high tangential irradiation fields increase the dosages received by the axillary region, but the average dosages received by the lower axillary regions are still less than 90% of the prescribed dose. (C) 2005 Elsevier Inc.
引用
收藏
页码:163 / 168
页数:6
相关论文
共 10 条
  • [1] Evaluation of level I and II axillary nodes included in the standard breast tangential fields and calculation of the administered dose: Results of a prospective study
    Aristei, C
    Chionne, F
    Marsella, AR
    Alessandro, M
    Rulli, A
    Lemmi, A
    Perrucci, E
    Latini, P
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2001, 51 (01): : 69 - 73
  • [2] Do all patients with sentinel node metastasis from breast carcinoma need complete axillary node dissection?
    Chu, KU
    Turner, RR
    Hansen, NM
    Brennan, MB
    Bilchik, A
    Giuliano, AE
    [J]. ANNALS OF SURGERY, 1999, 229 (04) : 536 - 541
  • [3] Meeting highlights: International Consensus Panel on the Treatment of Primary Breast Cancer
    Goldhirsch, A
    Glick, JH
    Gelber, RD
    Senn, HJ
    [J]. JOURNAL OF THE NATIONAL CANCER INSTITUTE, 1998, 90 (21) : 1601 - 1608
  • [4] The relationship between radiation fields and regional lymph nodes in carcinoma of the breast
    Goodman, RL
    Grann, A
    Saracco, P
    Needham, MF
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2001, 50 (01): : 99 - 105
  • [5] HARRIS JR, 2000, DIS BREAST, P5
  • [6] Is it possible to treat the axillary nodes in the same radiation fields covering the breast? A study to locate the limits of the axillary dissection relative to anatomic landmarks in the tangential fields
    Kiel, KD
    Chang, S
    Small, W
    Bethke, K
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1997, 39 (02): : 264 - 264
  • [7] Evaluation of a standard breast tangent technique: A dose-volume analysis of tangential irradiation using three dimensional tools
    Krasin, M
    McCall, A
    King, S
    Olson, M
    Emami, B
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2000, 47 (02): : 327 - 333
  • [8] Relationship of sentinel and axillary level I-II lymph nodes to tangential fields used in breast irradiation
    Schlembach, PJ
    Buchholz, TA
    Ross, MI
    Kirsner, SM
    Salas, GJ
    Strom, EA
    McNeese, MD
    Perkins, GH
    Hunt, KK
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2001, 51 (03): : 671 - 678
  • [9] Utility of three-dimensional planning for axillary node coverage with breast-conserving radiation therapy: Early experience
    Smitt, MC
    Goffinet, DR
    [J]. RADIOLOGY, 1999, 210 (01) : 221 - 226
  • [10] The modified tangential irradiation technique for breast cancer: How to cover the entire axillary region
    Takeda, A
    Shigematsu, N
    Kondo, M
    Amemiya, A
    Kawaguchi, O
    Sato, M
    Kutsuki, S
    Toya, K
    Ishibashi, R
    Kawase, T
    Tsukamoto, N
    Kubo, A
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2000, 46 (04): : 815 - 822