Seismic response analyses of an asymmetric base-isolated building during the 2011 Great East Japan (Tohoku) Earthquake

被引:40
|
作者
Siringoringo, Dionysius M. [1 ]
Fujino, Yozo [2 ]
机构
[1] Univ Tokyo, Dept Civil Engn, Tokyo 1138656, Japan
[2] Univ Tokyo, Inst Engn Innovat, Bunkyo Ku, Tokyo 1138656, Japan
基金
日本科学技术振兴机构;
关键词
building seismic monitoring; asymmetric base-isolated building; building torsional response; 2011 Great East Japan Earthquake; system identification; DYNAMIC STRUCTURAL SYSTEMS; IDENTIFICATION; RECORDS; BRIDGE;
D O I
10.1002/stc.1661
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Analysis of strong motion recordings of a base-isolated building during the March 11, 2011, Great East Japan (Tohoku) Earthquake is reported in this paper. The building, located in Tokyo Bay area, is an asymmetric L-shaped structure consisting of seven-story and 14-story building with vertical opening. Vibration monitoring system was installed on the building in 2010, and seismic responses were recorded including the strongest shaking (peak ground acceleration 0.80-1.40m/s(2)) experienced during the main shock of March 11, 2011, Great East Japan Earthquake. The building survived the earthquake without structural damage. The study in this paper includes response analysis, system identification, and seismic performance evaluation of the structure, especially performance of base-isolation system. The study shows that despite considerable shift in effective frequency of the building due to the increase in flexibility of isolation system during the main shock, large acceleration was recorded on the superstructure with the peak floor accelerations of nearly 300cm/s(2). Two factors contribute to this cause: one is the characteristics of the building where torsional modes dominate the seismic response of upper stories and the other is resonance, where dominant frequencies of ground motions coincide with the natural frequencies of torsional modes. Moreover, analysis shows that torsional modes were not significantly influenced by performance of base isolation, so that even though the base isolation has functioned properly, the upper stories still experienced large floor accelerations. The paper also discusses long-term observation of seismic responses during aftershocks and various levels of earthquakes between 2010 and 2012. Copyright (c) 2014 John Wiley & Sons, Ltd.
引用
收藏
页码:71 / 90
页数:20
相关论文
共 11 条
  • [1] Vibration characteristics change of a base-isolated building with semi-active dampers before, during, and after the 2011 Great East Japan earthquake
    Dan, Maki
    Ishizawa, Yuji
    Tanaka, Sho
    Nakahara, Shuchi
    Wakayama, Shizuka
    Kohiyama, Masayuki
    EARTHQUAKES AND STRUCTURES, 2015, 8 (04) : 889 - 913
  • [2] Seismic Response Analyses of the Yokohama Bay Cable-Stayed Bridge in the 2011 Great East Japan Earthquake
    Siringoringo, Dionysius M.
    Fujino, Yozo
    Namikawa, Kenji
    JOURNAL OF BRIDGE ENGINEERING, 2014, 19 (08)
  • [3] Temporal variation in modal properties of a base-isolated building during an earthquake
    Takewaki, Izuru
    Nakamura, Mitsuru
    JOURNAL OF ZHEJIANG UNIVERSITY-SCIENCE A, 2010, 11 (01): : 1 - 8
  • [4] Study on dynamic behavior of high-rise base-isolated building based on its responses recorded during the 2011 Tohoku-Oki earthquake
    Matsuda, Kazuhiro
    Kasai, Kazuhiko
    Journal of Structural and Construction Engineering, 2014, 79 (704): : 1445 - 1455
  • [5] Temporal variation in modal properties of a base-isolated building during an earthquake
    Izuru Takewaki
    Mitsuru Nakamura
    Journal of Zhejiang University-SCIENCE A, 2010, 11 : 1 - 8
  • [6] System identification of base-isolated building using seismic response data
    Furukawa, T
    Ito, M
    Izawa, K
    Noori, MN
    JOURNAL OF ENGINEERING MECHANICS-ASCE, 2005, 131 (03): : 268 - 275
  • [7] Estimation of changes in modal parameters of a seismically isolated building during the 2011 earthquake off the Pacific coast of Tohoku
    Saito, Tomoo
    HEALTH MONITORING OF STRUCTURAL AND BIOLOGICAL SYSTEMS 2012, 2012, 8348
  • [9] Responses of a Tall Building with US Code-Type Instrumentation in Tokyo, Japan, to Events Before, During, and After the Tohoku Earthquake of 11 March 2011
    Celebi, Mehmet
    Kashima, Toshihide
    Ghahari, S. Farid
    Abazarsa, Fariba
    Taciroglu, Ertugrul
    EARTHQUAKE SPECTRA, 2016, 32 (01) : 497 - 522
  • [10] Seismic response analysis and modal identification of a full-scale five-story base-isolated building tested on the NEES@UCSD shake table
    Astroza, Rodrigo
    Conte, Joel P.
    Restrepo, Jose I.
    Ebrahimian, Hamed
    Hutchinson, Tara
    ENGINEERING STRUCTURES, 2021, 238